Equivalent Mueller matrix method for 3-D axial error analysis in 2-D SoP measurement

被引:1
|
作者
Wang, Luo [1 ,2 ,3 ]
Zhang, Haiyang [1 ,2 ,3 ]
Jin, Fahong [1 ,2 ,3 ]
Zhao, Changming [1 ,2 ,3 ]
He, Jianwei [4 ]
机构
[1] Beijing Inst Technol, Sch Opt & Photon, Beijing 100081, Peoples R China
[2] Minist Educ, Key Lab Photoelect Imaging Technol & Syst, Beijing 100081, Peoples R China
[3] Minist Ind & Informat Technol, Key Lab Photon Informat Technol, Beijing 100081, Peoples R China
[4] China Eletron Technol Grp Corp, Acad Elect & Informat Technol, Beijing 100041, Peoples R China
关键词
POLARIZATION; NOISE; POLARIMETERS; PARAMETERS; SIGNAL; MINIMIZATION;
D O I
10.1364/JOSAB.514740
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We explored an equivalent Mueller matrix method for analyzing 3-D axial errors in 2-D polarization state measurements for the first time, to the best of our knowledge. The method treats 2-D devices with 3-D errors as a closed system, within which the transformation of a 3-D polarization field is described using a 3 x 3 coherency matrix and generalized Jones matrix (GJM). The equivalent 4 x 4 Mueller matrix of the component is numerically evaluated from the 2-D polarization field information at the input and output ports. Furthermore, our research has identified that any 3-D axial error within the polarization state analyzer (PSA) can be classified into two categories: axial alignment error (AAE) and wave -vector alignment error (WAE). For the latter case, we have introduced a concept of equal weight variance of a wave -vector as an alternative to the spiral sampling method to estimate the upper -bound of relative state of polarization (SoP) error. A simulation result shows that for the ideal bi-plate PSA, the upperbound remains below 3% when the deviation value is less than 17.7 deg. The equivalent Mueller matrix method can be applied to analyze the 3-D errors in an arbitrary sort of PSA, and the description of 3-D transformation in this paper is simpler than a 9 x 9 generalized Mueller matrix and nine -element generalized Stokes vector, which has potential value in the research of vector beam generation. (c) 2024 Optica Publishing Group
引用
收藏
页码:589 / 596
页数:8
相关论文
共 50 条
  • [31] A HYBRID METHOD FOR 2-D/3-D REGISTRATION BETWEEN 3-D VOLUMES AND 2-D ANGIOGRAPHY FOR TRANS-CATHETER AORTIC VALVE IMPLANTATION (TAVI)
    Miao, Shun
    Liao, Rui
    Zheng, Yefeng
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1215 - 1218
  • [32] An equivalent reduction of a 2-D symmetric polynomial matrix
    Karampetakis, Nikos P.
    2006 IEEE CONFERENCE ON COMPUTER-AIDED CONTROL SYSTEM DESIGN, VOLS 1 AND 2, 2006, : 88 - 93
  • [33] APPLICATION OF THE TELLURIC-MAGNETOTELLURIC METHOD IN 2-D AND 3-D ENVIRONMENTS
    STODT, J
    HOHMANN, GW
    TING, S
    GEOPHYSICS, 1979, 44 (03) : 401 - 401
  • [34] 2-D MR Spectroscopy Combined with 2-D/3-D Spatial Encoding
    Thomas, M. Albert
    Iqbal, Zohaib
    Sarma, Manoj K.
    Nagarajan, Rajakumar
    Macey, Paul M.
    Huda, Amir
    EMAGRES, 2016, 5 (01): : 1039 - 1060
  • [35] Efficient 3-D Measurement Method Based on Nonlinear Error Correction
    Shan, Shuo
    Li, Ze
    Zhang, Wen
    Xu, Peng
    Wang, Jianhua
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [36] MEASUREMENT OF THE LATERAL VENTRICLES IN THE NEONATAL HEAD: COMPARISON OF 2-D AND 3-D TECHNIQUES
    McLean, Glenda
    Coombs, Peter
    Sehgal, Arvind
    Paul, Eldho
    Zamani, Lily
    Gilbertson, Taryn
    Ptasznik, Ronnie
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (12): : 2051 - 2057
  • [37] Coordinate measurement in 2-D and 3-D geometries using frequency scanning interferometry
    Gibson, SM
    Coe, PA
    Mitra, A
    Howell, DF
    Nickerson, RB
    OPTICS AND LASERS IN ENGINEERING, 2005, 43 (07) : 815 - 831
  • [38] THE GENERATION OF DIFFERENCE AND ERROR FORMULAS FOR ARBITRARY 2-D AND 3-D GRIDS AND ARBITRARY ORDER
    SCHONAUER, W
    WIETSCKORKE, H
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1986, 66 (05): : T324 - T327
  • [39] A Measurement System to Realize 3-D Carotid Occlusion Measurement From 2-D Conventional Ultrasonography
    Capriglione, Domenico
    Ferrigno, Luigi
    Miele, Gianfranco
    Paciello, Vincenzo
    Paolillo, Alfredo
    Sommella, Paolo
    IEEE SENSORS JOURNAL, 2014, 14 (03) : 747 - 757
  • [40] Assembling 2-D Blocks into 3-D Chips
    Knechtel, Johann
    Markov, Igor L.
    Lienig, Jens
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2012, 31 (02) : 228 - 241