Equivalent Mueller matrix method for 3-D axial error analysis in 2-D SoP measurement

被引:1
|
作者
Wang, Luo [1 ,2 ,3 ]
Zhang, Haiyang [1 ,2 ,3 ]
Jin, Fahong [1 ,2 ,3 ]
Zhao, Changming [1 ,2 ,3 ]
He, Jianwei [4 ]
机构
[1] Beijing Inst Technol, Sch Opt & Photon, Beijing 100081, Peoples R China
[2] Minist Educ, Key Lab Photoelect Imaging Technol & Syst, Beijing 100081, Peoples R China
[3] Minist Ind & Informat Technol, Key Lab Photon Informat Technol, Beijing 100081, Peoples R China
[4] China Eletron Technol Grp Corp, Acad Elect & Informat Technol, Beijing 100041, Peoples R China
关键词
POLARIZATION; NOISE; POLARIMETERS; PARAMETERS; SIGNAL; MINIMIZATION;
D O I
10.1364/JOSAB.514740
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We explored an equivalent Mueller matrix method for analyzing 3-D axial errors in 2-D polarization state measurements for the first time, to the best of our knowledge. The method treats 2-D devices with 3-D errors as a closed system, within which the transformation of a 3-D polarization field is described using a 3 x 3 coherency matrix and generalized Jones matrix (GJM). The equivalent 4 x 4 Mueller matrix of the component is numerically evaluated from the 2-D polarization field information at the input and output ports. Furthermore, our research has identified that any 3-D axial error within the polarization state analyzer (PSA) can be classified into two categories: axial alignment error (AAE) and wave -vector alignment error (WAE). For the latter case, we have introduced a concept of equal weight variance of a wave -vector as an alternative to the spiral sampling method to estimate the upper -bound of relative state of polarization (SoP) error. A simulation result shows that for the ideal bi-plate PSA, the upperbound remains below 3% when the deviation value is less than 17.7 deg. The equivalent Mueller matrix method can be applied to analyze the 3-D errors in an arbitrary sort of PSA, and the description of 3-D transformation in this paper is simpler than a 9 x 9 generalized Mueller matrix and nine -element generalized Stokes vector, which has potential value in the research of vector beam generation. (c) 2024 Optica Publishing Group
引用
收藏
页码:589 / 596
页数:8
相关论文
共 50 条
  • [11] THE SPINE IN 3-D - COMPUTED TOMOGRAPHIC REFORMATION FROM 2-D AXIAL SECTIONS
    VIRAPONGSE, C
    GMITRO, A
    SARWAR, M
    SPINE, 1986, 11 (06) : 513 - 520
  • [12] A new method for 3-D velocity vector measurement using 2-D phased array probe
    Shiina, T
    Nitta, N
    ACOUSTICAL IMAGING, VOL 24, 2000, 24 : 193 - 199
  • [13] FOURIER MODELING - AN EFFICIENT 2-D AND 3-D MODELING METHOD
    KOSLOFF, D
    GEOPHYSICS, 1985, 50 (07) : 1192 - 1192
  • [14] 2-D vision directing laser device for 3-D measurement and modeling
    Wong, AKC
    Xu, T
    Fayek, RE
    2000 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2000), VOLS 1-3, PROCEEDINGS, 2000, : 96 - 102
  • [15] Error analysis of phase screen method in 3-D
    Cheng, NY
    Cheng, CH
    Toksoz, MN
    GEOPHYSICAL RESEARCH LETTERS, 1996, 23 (14) : 1841 - 1844
  • [16] Geometrical properties between 2-D image plane and 3-D error space
    Koh, Sung Shik
    Zin, Thi Thi
    Hama, Hiromitsu
    IEICE ELECTRONICS EXPRESS, 2006, 3 (14): : 333 - 339
  • [17] A simple 2-D/3-D method for fast analysis of patch resonators with high accuracy
    Torabian, A
    Chow, YL
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2001, 49 (03) : 470 - 474
  • [18] VORTICES IN 2-D AND 3-D SUPERFLUIDS
    BOWLEY, RM
    JOURNAL OF LOW TEMPERATURE PHYSICS, 1992, 87 (3-4) : 137 - 196
  • [19] 2-D approaches to a 3-D problem
    Lamb, RG
    HYDROCARBON PROCESSING, 1998, 77 (04): : 175 - 175
  • [20] Polyelectrolytes of 2-D and 3-D polyphenylenes
    Mihov, G
    Bauer, RE
    Tchebotareva, N
    Knoll, W
    Schmidt, M
    Thünemann, AF
    Müllen, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U476 - U476