Novel study on inverse convection-conduction heat transfer for plate-finned tube heat exchanger

被引:2
|
作者
Chen, Han-Taw [1 ]
Hsu, Li-Yuan [1 ]
Yan, Wei-Mon [2 ,3 ]
Rashidi, Saman [4 ]
Hung, Hung-Hsiu [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 701, Taiwan
[2] Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 10608, Taiwan
[3] Natl Taipei Univ Technol, Res Ctr Energy Conservat New Generat Residential C, Taipei 10608, Taiwan
[4] Semnan Univ, Fac New Sci & Technol, Dept Energy, Semnan, Iran
关键词
Inverse convection-conduction; Staggered pipes; Fin-tube heat exchanger; Experimental temperature measurements; Energy efficiency; NATURAL-CONVECTION; NUMERICAL-SIMULATION; SENSITIVITY-ANALYSIS; MIXED CONVECTION; SQUARE ENCLOSURE; CYLINDERS; NANOFLUID; CHANNEL; PERFORMANCE; ARRAY;
D O I
10.1007/s10973-024-13111-w
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the inverse 3D computational fluid dynamics method combined with the least squares method and excessive experimental temperature measurements is employed for the prediction of the unknown heat transfer rate and free convection heat transfer features and select an approximate flow model for the plate-finned tube heat exchanger. The results indicate that the heat transfer coefficient h<overline>f2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\overline{h}_{{{\text{f2}}}}$$\end{document} on the second fin estimated by the ZEM is closer to the existing inverse result than other flow models. In addition, its root-mean-square error is also small enough in all used flow models. The obtained values of h<overline>f2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\overline{h}_{{{\text{f2}}}}$$\end{document} and RMSE agree with those obtained from the isothermal assumption. Thus, this inverse technique has good accuracy and reliability. This inverse technique also needs less experimental temperature data than the isothermal assumption. The temperature and heat dissipation for each pipe and fin can also be estimated. The influence of the flow model and the vertical distance between two vertical pipes on the obtained estimates is also investigated. The mean dissipative heat transfer rates of per pipe for the vertical distances between centers of two pipes (Stv) of 0.054 m, 0.045 m, and 0.036 m are 10.72 W, 12.12 W, and 10.28 W, respectively. The heat losses in this study for Stv = 0.054 m, 0.045 m, and 0.036 m are 2.7%, 3.0%, and 4.5%, respectively.
引用
收藏
页码:6211 / 6226
页数:16
相关论文
共 50 条
  • [31] Numerical study of PCMs arrangement effect on heat transfer performance in plate-finned heat sink for passive cooling system
    Bondareva, Nadezhda S.
    Sheremet, Mikhail A.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (19) : 10305 - 10317
  • [32] Thermal Performance Study of Plate-finned Vapor Chamber Heat Sink
    Al-Rahman, Mohammed A.
    Ibrahim, Saeed A. A.
    Elrefaie, M. Elfaisal
    JOURNAL OF APPLIED AND COMPUTATIONAL MECHANICS, 2024, 10 (02): : 304 - 316
  • [33] Using the Inverse Method to Investigate Flow Models for Mixed Convection of Annular Finned Tube Heat Exchanger
    Chen, Han-Taw
    You, Cheng-Hui
    Hsu, Wei-Lun
    Chang, Jiang-Ren
    JOURNAL OF MARINE SCIENCE AND TECHNOLOGY-TAIWAN, 2021, 29 (05): : 652 - 665
  • [34] Numerical Simulation of Convection-Conduction Heat Transfer in a Block of Rectangular Microchannels
    V. I. Artemov
    A. I. Leontiev
    A. F. Polyakov
    High Temperature, 2005, 43 : 580 - 594
  • [35] Numerical study of PCMs arrangement effect on heat transfer performance in plate-finned heat sink for passive cooling system
    Nadezhda S. Bondareva
    Mikhail A. Sheremet
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 10305 - 10317
  • [36] Effect of domain boundary set on natural convection heat transfer characteristics for vertical annular finned tube heat exchanger
    Chen, Han-Taw
    Chiu, Yu-Jie
    Tseng, Hung-Chia
    Chang, Jiang-Ren
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 109 : 668 - 682
  • [37] INSPECTION METHOD OF FINNED TUBE AND FINNED HEAT EXCHANGER
    Ding, Ju
    Zhang, Min
    Liu, Shuhong
    Wang, Shenghui
    Wang, Jielu
    PROCEEDINGS OF ASME 2021 PRESSURE VESSELS AND PIPING CONFERENCE (PVP2021), VOL 5, 2021,
  • [38] PARAMETRIC STUDY OF OPERATING AND GEOMETRY CHARACTERISTICS EFFECT ON HEAT TRANSFER IN ANNULAR FINNED TUBE HEAT EXCHANGER
    Sencic, Tomislav
    Trp, Anica
    Lenic, Kristian
    ENGINEERING REVIEW, 2009, 29 (01) : 25 - 36
  • [39] Study on heat transfer enhancement of petal-shaped finned tube heat exchanger with helical baffles
    Zhang, Z.G.
    Fang, X.M.
    Lin, P.S.
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2001, 22 (05):
  • [40] Study of the influence of the lack of contact in plate fin and tube heat exchanger on heat transfer
    Andrzejewski, Dariusz
    Lecki, Marcin
    Gutkowski, Artur
    ARCHIVES OF THERMODYNAMICS, 2018, 39 (03) : 63 - 83