Novel study on inverse convection-conduction heat transfer for plate-finned tube heat exchanger

被引:2
|
作者
Chen, Han-Taw [1 ]
Hsu, Li-Yuan [1 ]
Yan, Wei-Mon [2 ,3 ]
Rashidi, Saman [4 ]
Hung, Hung-Hsiu [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 701, Taiwan
[2] Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 10608, Taiwan
[3] Natl Taipei Univ Technol, Res Ctr Energy Conservat New Generat Residential C, Taipei 10608, Taiwan
[4] Semnan Univ, Fac New Sci & Technol, Dept Energy, Semnan, Iran
关键词
Inverse convection-conduction; Staggered pipes; Fin-tube heat exchanger; Experimental temperature measurements; Energy efficiency; NATURAL-CONVECTION; NUMERICAL-SIMULATION; SENSITIVITY-ANALYSIS; MIXED CONVECTION; SQUARE ENCLOSURE; CYLINDERS; NANOFLUID; CHANNEL; PERFORMANCE; ARRAY;
D O I
10.1007/s10973-024-13111-w
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the inverse 3D computational fluid dynamics method combined with the least squares method and excessive experimental temperature measurements is employed for the prediction of the unknown heat transfer rate and free convection heat transfer features and select an approximate flow model for the plate-finned tube heat exchanger. The results indicate that the heat transfer coefficient h<overline>f2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\overline{h}_{{{\text{f2}}}}$$\end{document} on the second fin estimated by the ZEM is closer to the existing inverse result than other flow models. In addition, its root-mean-square error is also small enough in all used flow models. The obtained values of h<overline>f2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\overline{h}_{{{\text{f2}}}}$$\end{document} and RMSE agree with those obtained from the isothermal assumption. Thus, this inverse technique has good accuracy and reliability. This inverse technique also needs less experimental temperature data than the isothermal assumption. The temperature and heat dissipation for each pipe and fin can also be estimated. The influence of the flow model and the vertical distance between two vertical pipes on the obtained estimates is also investigated. The mean dissipative heat transfer rates of per pipe for the vertical distances between centers of two pipes (Stv) of 0.054 m, 0.045 m, and 0.036 m are 10.72 W, 12.12 W, and 10.28 W, respectively. The heat losses in this study for Stv = 0.054 m, 0.045 m, and 0.036 m are 2.7%, 3.0%, and 4.5%, respectively.
引用
收藏
页码:6211 / 6226
页数:16
相关论文
共 50 条
  • [21] A three-dimensional unsteady numerical analysis for a plate-finned tube heat exchanger in the middle Reynolds number range
    Onishi, H
    Inaoka, K
    Suzuki, K
    COMPACT HEAT EXCHANGERS AND ENHANCEMENT TECHNOLOGY FOR THE PROCESS INDUSTRIES-2001, 2001, : 9 - 16
  • [22] RADIATIVE EFFECT ON THE CONJUGATED FORCED CONVECTION-CONDUCTION ANALYSIS OF HEAT-TRANSFER IN A PLATE FIN
    LIEN, FS
    CHEN, CK
    AIAA JOURNAL, 1985, 23 (10) : 1645 - 1647
  • [24] RADIATIVE EFFECT ON THE CONJUGATED FORCED CONVECTION-CONDUCTION ANALYSIS OF HEAT TRANSFER IN A PLATE FIN.
    Lien, Fue-Sang
    Chen, Cha'o-Kuang
    Cleaver, John W.
    1645, (23):
  • [25] Numerical simulation of natural convection heat transfer for annular elliptical finned tube heat exchanger with experimental data
    Chen, Han-Taw
    Hsieh, Yi-Lun
    Chen, Ping-Chou
    Lin, Yi-Fan
    Liu, Kuo-Chi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 : 541 - 554
  • [26] Optimal Value of Finning Coefficient of Plate-Finned Heat Transfer Surface.
    Berman, Ya.A.
    Man'kovskii, O.N.
    Rafalovich, A.P.
    Teploenergetika, 1982, (03): : 54 - 55
  • [27] Effect of edge region on heat transfer and pressure drop performances of small plain plate-finned tube bundles
    Ma, Ting
    Chu, Wen-Xiao
    Yu, Peng-Qing
    Zeng, Min
    Wang, Qiu-Wang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2014, 35 (01): : 155 - 159
  • [28] Conjugate forced convection-conduction heat transfer analysis of a heat generating vertical cylinder
    Jilani, G
    Jayaraj, S
    Ahmad, MA
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (02) : 331 - 341
  • [29] Study on the enhanced heat transfer and exergy performance of the finned tube heat exchanger with vortex generator
    Liang, Xingyu
    Min, Min
    Bian, Kaikai
    Cheng, Junlin
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 210
  • [30] Numerical simulation of convection-conduction heat transfer in a block of rectangular microchannels
    Artemov, VI
    Leontiev, AI
    Polyakov, AF
    HIGH TEMPERATURE, 2005, 43 (04) : 580 - 594