Ultra-sensitive fluorescent immunoassay based on bright AIE nanoparticle for biomarkers detection and quantification

被引:6
|
作者
Hu, Yaxin [1 ,2 ]
Cheng, Song [2 ]
Chen, Lidan [4 ]
Xie, Li [2 ]
Fu, Haihai [2 ]
Sun, Zhaohui [4 ]
Hu, Rong [2 ,3 ]
Liu, Yong [2 ]
Wang, Zhiming [1 ,2 ]
Tang, Ben Zhong [5 ]
机构
[1] South China Univ Technol, Ctr Aggregat Induced Emiss, State Key Lab Luminescent Mat & Devices, Guangzhou 510640, Peoples R China
[2] South China Univ Technol, AIE Inst, Guangzhou 510640, Peoples R China
[3] Univ South China, Sch Chem & Chem Engn, Hengyang 421001, Peoples R China
[4] Gen Hosp Southern Theater Command, Dept Lab Med, Guangzhou, Guangdong, Peoples R China
[5] Chinese Univ Hong Kong, Shenzhen Inst Aggregate Sci & Technol, Sch Sci & Engn, Shenzhen 518172, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Aggregation -induced emission; Nanoparticles; Biosensors; Fluorescence immunoassay; LINKED-IMMUNOSORBENT-ASSAY; QUANTITATIVE DETECTION;
D O I
10.1016/j.snb.2024.135562
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fluorescence immunoassay (FIA) is one of the most immunoassay diagnosis methods in clinic for biomarker quantification in recent years. The development of reliable FIA strategy with high-sensitivity, large-rang and outstanding efficiency for biomarkers rapid diagnosis, especially in complicated samples, is still a great challenge. Herein, an ultra-sensitive FIA combined with magnetic separation was established to achieve efficient point-of-care diagnosis in quantitative behavior based on bright aggregation-induced emission nanoparticles (AIE NPs). By utilizing swelling method, AIE NPs with controllable size, relatively high luminescence efficiency and large Stokes shift were prepared, moreover, the obtained NPs also exhibit narrow size distribution and well-defined spherical morphology. Stability studies prove that AIE NPs not only possess quite high photostability, but also present good resistance towards harsh acid-alkaline steadily. By using AIE NPs as the reporter, a reliable and efficient FIA sensor was successfully constructed. The precise detection of C-reaction protein (CRP) antigen was acquired with the linear range of 0.5 ng<middle dot>mL(-1) similar to 1000 ng<middle dot>mL(-1) and the limit of detection (LOD) of 0.35 ng<middle dot>mL(-1), which is comparative with the conventional chemiluminescence immunoassays. Moreover, the whole detection operation could be accomplished within 10 min, which is relatively rapid and desirable for point-of-care diagnosis. In addition, this strategy also presented excellent specificity towards CRP antigens among various inflammatory antigens. These results confirm that AIE NPs-based FIA strategy provides an ideal and reliable approach for precise and quantitive biosensing of in vitro diagnostics.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] An ultra-sensitive ratiometric fluorescent thermometer based on monomer and excimer dual emission
    Feng, Weixu
    Wu, Yanhui
    Chen, Dong
    Lu, Sumin
    Zhao, Yan
    Yan, Hongxia
    CHEMICAL COMMUNICATIONS, 2023, 59 (100) : 14823 - 14826
  • [42] An Ultra-Sensitive Optical Ring-Based Micro-Resonator Model towards Nanoparticle and Protein Detection
    Ahmeti, Faruk
    Teker, Kasif
    JOURNAL OF NANO RESEARCH, 2018, 55 : 57 - 65
  • [43] Ultra-Sensitive Si-Based Optical Sensor for Nanoparticle-Size Traditional Water Pollutant Detection
    Emara, Ahmed
    Yousef, Amr
    Elleithy, Khaled
    PHOTONICS, 2022, 9 (05)
  • [44] Current Perspectives in Ultra-sensitive Detection of Cancer-specific Biomarkers and Therapeutic Targets
    Savvateeva, Lyudmila V.
    Zernii, Evgeni Yu.
    Zamyatnin, Andrey A.
    CURRENT CANCER DRUG TARGETS, 2023, 23 (11) : 829 - 833
  • [45] Ultra-sensitive detection of kanamycin for food safety using a reduced graphene oxide-based fluorescent aptasensor
    Na-Reum Ha
    In-Pil Jung
    Im-Joung La
    Ho-Sup Jung
    Moon-Young Yoon
    Scientific Reports, 7
  • [46] An ultra-sensitive nanoarray chip based on single-molecule sandwich immunoassay and TIRFM for protein detection in biologic fluids
    Lee, Seungah
    Cho, Nam-Pyo
    Kim, Jung Dong
    Jung, Hyungil
    Kang, Seong Ho
    ANALYST, 2009, 134 (05) : 933 - 938
  • [47] Aptasensor based on cascaded fluorescent sensor assisted by exonuclease III for ultra-sensitive detection of Hg2+
    Liu, Xing
    Liu, Zhen
    Pan, Yiliang
    Xiao, Xilin
    ANALYTICAL SCIENCES, 2025, 41 (01) : 63 - 69
  • [48] Ultra-sensitive detection of kanamycin for food safety using a reduced graphene oxide-based fluorescent aptasensor
    Ha, Na-Reum
    Jung, In-Pil
    La, Im-Joung
    Jung, Ho-Sup
    Yoon, Moon-Young
    SCIENTIFIC REPORTS, 2017, 7
  • [49] Aptasensor based on cascaded fluorescent sensor assisted by exonuclease III for ultra-sensitive detection of Hg2+
    Liu, Xing
    Liu, Zhen
    Pan, Yiliang
    Xiao, Xilin
    Analytical Sciences, 2024,
  • [50] An ultra-sensitive and ratiometric fluorescent probe based on the DTBET process for Hg2+ detection and imaging applications
    Jiang, Yin
    Duan, Qinya
    Zheng, Guansheng
    Yang, Liu
    Zhang, Jie
    Wang, Yafeng
    Zhang, Huatang
    He, Jun
    Sun, Hongyan
    Ho, Derek
    ANALYST, 2019, 144 (04) : 1353 - 1360