Ultra-sensitive fluorescent immunoassay based on bright AIE nanoparticle for biomarkers detection and quantification

被引:6
|
作者
Hu, Yaxin [1 ,2 ]
Cheng, Song [2 ]
Chen, Lidan [4 ]
Xie, Li [2 ]
Fu, Haihai [2 ]
Sun, Zhaohui [4 ]
Hu, Rong [2 ,3 ]
Liu, Yong [2 ]
Wang, Zhiming [1 ,2 ]
Tang, Ben Zhong [5 ]
机构
[1] South China Univ Technol, Ctr Aggregat Induced Emiss, State Key Lab Luminescent Mat & Devices, Guangzhou 510640, Peoples R China
[2] South China Univ Technol, AIE Inst, Guangzhou 510640, Peoples R China
[3] Univ South China, Sch Chem & Chem Engn, Hengyang 421001, Peoples R China
[4] Gen Hosp Southern Theater Command, Dept Lab Med, Guangzhou, Guangdong, Peoples R China
[5] Chinese Univ Hong Kong, Shenzhen Inst Aggregate Sci & Technol, Sch Sci & Engn, Shenzhen 518172, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Aggregation -induced emission; Nanoparticles; Biosensors; Fluorescence immunoassay; LINKED-IMMUNOSORBENT-ASSAY; QUANTITATIVE DETECTION;
D O I
10.1016/j.snb.2024.135562
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fluorescence immunoassay (FIA) is one of the most immunoassay diagnosis methods in clinic for biomarker quantification in recent years. The development of reliable FIA strategy with high-sensitivity, large-rang and outstanding efficiency for biomarkers rapid diagnosis, especially in complicated samples, is still a great challenge. Herein, an ultra-sensitive FIA combined with magnetic separation was established to achieve efficient point-of-care diagnosis in quantitative behavior based on bright aggregation-induced emission nanoparticles (AIE NPs). By utilizing swelling method, AIE NPs with controllable size, relatively high luminescence efficiency and large Stokes shift were prepared, moreover, the obtained NPs also exhibit narrow size distribution and well-defined spherical morphology. Stability studies prove that AIE NPs not only possess quite high photostability, but also present good resistance towards harsh acid-alkaline steadily. By using AIE NPs as the reporter, a reliable and efficient FIA sensor was successfully constructed. The precise detection of C-reaction protein (CRP) antigen was acquired with the linear range of 0.5 ng<middle dot>mL(-1) similar to 1000 ng<middle dot>mL(-1) and the limit of detection (LOD) of 0.35 ng<middle dot>mL(-1), which is comparative with the conventional chemiluminescence immunoassays. Moreover, the whole detection operation could be accomplished within 10 min, which is relatively rapid and desirable for point-of-care diagnosis. In addition, this strategy also presented excellent specificity towards CRP antigens among various inflammatory antigens. These results confirm that AIE NPs-based FIA strategy provides an ideal and reliable approach for precise and quantitive biosensing of in vitro diagnostics.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Rapid and sensitive HBsAg immunoassay based on fluorescent nanoparticle labels and time-resolved detection
    Valanne, A
    Huopalahti, S
    Vainionpää, R
    Härmä, H
    Lovgren, T
    JOURNAL OF VIROLOGICAL METHODS, 2005, 129 (01) : 83 - 90
  • [22] Ultra-sensitive method based on time-resolved fluorescence immunoassay for detection of sulfamethazine in raw milk
    Hu, Song
    Li, Danhong
    Huang, Zhen
    Xing, Keyu
    Chen, Yuan
    Peng, Juan
    Lai, Weihua
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2018, 29 (01) : 1137 - 1149
  • [23] Ultra-sensitive, stable isotope assisted quantification of multiple urinary mycotoxin exposure biomarkers
    Sarkanj, Bojan
    Ezekiel, Chibundu N.
    Turner, Paul C.
    Abia, Wilfred A.
    Rychlik, Michael
    Krska, Rudolf
    Sulyok, Michael
    Warth, Benedikt
    ANALYTICA CHIMICA ACTA, 2018, 1019 : 84 - 92
  • [24] Ultra-sensitive detection of IgE using biofunctionalized nanoparticle-enhanced SPR
    Kim, Suhee
    Lee, Jaeyoung
    Lee, Seok Jae
    Lee, Hye Jin
    TALANTA, 2010, 81 (4-5) : 1755 - 1759
  • [25] Nickel nanoparticle-modified electrode for ultra-sensitive electrochemical detection of insulin
    Yu, Yanan
    Guo, Meisong
    Yuan, Mengwei
    Liu, Weitong
    Hu, Jingbo
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 215 - 219
  • [26] Rapid and sensitive detection of wood smoke exposure biomarkers using europium fluorescent nanoparticle label/lateral flow immunoassay
    Fu, Yonghao
    Song, Yang
    Yang, Zhansen
    Ruan, Xiaofan
    Lin, Yuehe
    Du, Dan
    TALANTA, 2025, 291
  • [27] Surround optical fiber immunoassay (SOFIA): An ultra-sensitive assay for prion protein detection
    Chang, Binggong
    Gray, Perry
    Piltch, Martin
    Bulgin, Marie S.
    Sorensen-Melson, Sharon
    Miller, Michael W.
    Davies, Paul
    Brown, David R.
    Coughlin, Daniel R.
    Rubenstein, Richard
    JOURNAL OF VIROLOGICAL METHODS, 2009, 159 (01) : 15 - 22
  • [28] Ultra-sensitive multiplexed detection of protein cancer biomarkers with signal amplification strategy
    Dekaliuk, M.
    FEBS OPEN BIO, 2024, 14 : 413 - 413
  • [29] Ultra-sensitive detection of explosives in solution and film as well as the development of thicker film effectiveness by tetraphenylethene moiety in AIE active fluorescent conjugated polymer
    Ghosh, Khama Rani
    Saha, Sukanta Kumar
    Wang, Zhi Yuan
    POLYMER CHEMISTRY, 2014, 5 (19) : 5638 - 5643
  • [30] A fluorescent sensor based on the cascade signal amplification strategy for ultra-sensitive detection of Cu2+
    Huang, Ruijia
    Xu, Ying
    Du, Jihui
    Guan, Qiong
    Cai, Xiaoqing
    Li, Feng
    Wang, Jidong
    Chen, Wenwen
    NANOSCALE, 2023, 15 (04) : 1806 - 1812