AN OPTOELECTRONIC SWITCH WITH INCREASED SENSITIVITY USING A FINGER STRUCTURE ELECTRODE

被引:0
|
作者
BERGNER, H [1 ]
BRUCKNER, V [1 ]
KERSTAN, F [1 ]
LENZNER, M [1 ]
NOWICK, W [1 ]
机构
[1] TECH UNIV KARL MARX STADT,DEPT PHYS,KARL MARX STADT,GER DEM REP
来源
关键词
D O I
10.1002/pssa.2211030121
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
引用
收藏
页码:193 / 197
页数:5
相关论文
共 50 条
  • [31] HIGH-SENSITIVITY AND HIGH-GAIN OPTICAL FUNCTIONAL DEVICE - TRIANGULAR-BARRIER OPTOELECTRONIC SWITCH (TOPS)
    SAKATA, H
    UTAKA, K
    MATSUSHIMA, Y
    ELECTRONICS LETTERS, 1994, 30 (21) : 1792 - 1793
  • [32] Enhanced Adhesion of Polydimethylsiloxane Using an Interlocked Finger Structure
    An, Suyeong
    Kim, Hyun Jin
    Chi, Sangwon
    Lee, Jonghwi
    MACROMOLECULAR RAPID COMMUNICATIONS, 2018, 39 (15)
  • [33] Increased sensitivity of anodic stripping voltammetry at the hanging mercury drop electrode by ultracathodic deposition
    Rodrigues, Jose A.
    Rodrigues, Carlos M.
    Almeida, Paulo J.
    Valente, Ines M.
    Goncalves, Luis M.
    Compton, Richard G.
    Barros, Aquiles A.
    ANALYTICA CHIMICA ACTA, 2011, 701 (02) : 152 - 156
  • [34] High-speed electro-optic switch using buried electrode structure in polymer Mach-Zehnder waveguide
    Sun, Jingwen
    Sun, Jian
    Yi, Yunji
    Qv, Lucheng
    Sun, Shiqi
    Wang, Fei
    Wang, Xibin
    Zhang, Daming
    MODERN PHYSICS LETTERS B, 2016, 30 (06):
  • [35] DESIGN AND PERFORMANCE OF AN OPTOELECTRONIC MATRIX SWITCH USING SI-P-I-N PHOTODIODES
    AIDA, K
    MATSUNO, K
    TOYOSHIMA, M
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 1988, 6 (01) : 131 - 138
  • [36] A HIGH-SPEED OPTOELECTRONIC MATRIX SWITCH USING HETEROJUNCTION SWITCHING PHOTO-DIODES
    HARA, EH
    MACHIDA, S
    IKEDA, M
    KANBE, H
    KIMURA, T
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1981, 17 (08) : 1539 - 1546
  • [37] Amperometric Biosensor: Increased Sensitivity Using Enzyme Nanoparticles
    Sharma, Shikha
    Shrivastav, Aditi
    Gupta, Nidhi
    Srivastava, Sudha
    NANOTECHNOLOGY AND BIOSENSORS, 2011, : 24 - 27
  • [38] Increased sensitivity in neuroimaging analyses using robust regression
    Wager, TD
    Keller, MC
    Lacey, SC
    Jonides, J
    NEUROIMAGE, 2005, 26 (01) : 99 - 113
  • [39] A high-sensitivity silicon accelerometer with a folded-electrode structure
    Yazdi, N
    Najafi, K
    Salian, AS
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2003, 12 (04) : 479 - 486
  • [40] Increased IEF Throughput Using a Dual-Electrode Assembly
    Smejkal, Gary B.
    Bauer, Darren J.