DETERMINATION OF REFERENCE TEMPERATURES FOR COLD TEST IN DIGITAL PLETHYSMOGRAPHY

被引:0
|
作者
PISTORIUS, MA
BRIANT, C
PLANCHON, B
机构
关键词
STRAIN-GAUGE PLETHYSMOGRAPHY; COLD TEST;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background. The purpose of this study was to determine optimal warm and cold temperatures for performance of a cold test. Methods. Thirty-six healthy volunteers (22 women and 14 men; mean age 40, 94 years, range: 20-58) were included in the study. Plethysmographic signal amplitudes were evaluated at different temperatures (47, 45, 43, 40, 35, 20, 15, 13, 11 and 9-degrees-C) under standardized conditions, using digital strain-gauge plethysmographic (Perivein Janssen). Reproducibility was assessed by repetition in the same subject of six digital plethysmography signal measurements at 45-degrees-C performed at different times and days. Clinical tolerance was estimated according to an analogue scale. Results. Maximal warm amplitude was obtained at 45-degrees-C and maximal vasoconstriction at 13-degrees-C. The thermal test was well tolerated for the temperature range between 11 and 45-degrees-C. Reproducibility of the measurements was satisfactory. Conclusions. 45-degrees-C is the nonnociceptive reproducible vasoparalyzing reference temperature, allowing measurement of maximal digital circulatory capacities. 11-degrees-C should be adopted as the optimal vasoconstriction temperature for performance of a cold test (J Mal Vasc 1994; 19: pages 195-198).
引用
收藏
页码:195 / 198
页数:4
相关论文
共 50 条
  • [41] A PERIPHERAL VASCULAR INSUFFICIENCY TEST USING PHOTOCELL PLETHYSMOGRAPHY
    SAMUELOFF, S
    MIDAY, R
    WASSERMAN, D
    BEHRENS, V
    HORNUNG, R
    ASBURRY, W
    DOYLE, T
    DUKESDOBOS, F
    BADGER, D
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1981, 23 (09) : 643 - 646
  • [42] Cold test on the vigor determination of Carthamus tinctorius L. seeds
    Coelho, Mirelle Vaz
    da Silva, Givanildo Zildo
    Hungria de Lima e Silva, Ingrid Maressa
    de Oliveira Paz, Rogerio Borges
    Sousa Silva, Amalia Andreza
    Gama, Gabriela Fernandes
    Machado, Carla Gomes
    REVISTA BRASILEIRA DE CIENCIAS AGRARIAS-AGRARIA, 2021, 16 (04):
  • [43] Respiratory Inductance Plethysmography is suitable for voluntary hyperventilation test
    Calabrese, Pascale
    Besleaga, Tudor
    Eberhard, Andre
    Vovc, Victor
    Baconnier, Pierre
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1055 - +
  • [44] Using a digital channel of a test system as an analog reference for wireless SOC testing
    McAleenan, R
    Kelly, J
    29TH INTERNATIONAL ELECTRONICS MANUFACTURING TECHNOLOGY SYMPOSIUM, 2004, : 194 - 197
  • [45] Determination of heat fluxes and surface temperatures during magnetron sputtering with a cold and hot target
    Bychkov, S. P.
    25TH INTERNATIONAL CONFERENCE ON VACUUM TECHNIQUE AND TECHNOLOGY, 2018, 387
  • [46] STATISTICAL PROCESSING OF THE RESULTS OF SERIAL IMPACT TOUGHNESS TESTS AND DETERMINATION OF THE TEMPERATURES OF COLD BRITTLENESS
    KARNAUKH, AI
    NEVYADOMSKAYA, AI
    INDUSTRIAL LABORATORY, 1979, 45 (07): : 801 - 802
  • [47] Reference values for pulmonary volumes by plethysmography in a Brazilian sample of white adults
    Lessa, Thamine
    de Castro Pereira, Carlos Alberto
    Soares, Maria Raquel
    Matos, Renato
    Guimaraes, Virginia Pacheco
    Sanches, Giancarlo
    Rassi, Roberto Helou
    Maia, Israel
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2019, 45 (03)
  • [48] Aortic Frequency Response Determination via Bioimpedance Plethysmography
    Kusche, Roman
    Lindenberg, Arthur-Vincent
    Hauschild, Sebastian
    Ryschka, Martin
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (11) : 3238 - 3246
  • [49] The current state of digital reference: validation of a general digital reference model through a survey of digital reference services
    Pomerantz, J
    Nicholson, S
    Belanger, Y
    Lankes, RD
    INFORMATION PROCESSING & MANAGEMENT, 2004, 40 (02) : 347 - 363
  • [50] ON LINE DETERMINATION OF AIRWAY-RESISTANCE BY PLETHYSMOGRAPHY AND MICROCOMPUTER
    LORINO, AM
    LORINO, H
    MARIETTE, C
    PELLE, G
    HARF, A
    ATLAN, G
    COMPUTERS IN BIOLOGY AND MEDICINE, 1985, 15 (04) : 197 - 203