DETERMINATION OF REFERENCE TEMPERATURES FOR COLD TEST IN DIGITAL PLETHYSMOGRAPHY

被引:0
|
作者
PISTORIUS, MA
BRIANT, C
PLANCHON, B
机构
关键词
STRAIN-GAUGE PLETHYSMOGRAPHY; COLD TEST;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background. The purpose of this study was to determine optimal warm and cold temperatures for performance of a cold test. Methods. Thirty-six healthy volunteers (22 women and 14 men; mean age 40, 94 years, range: 20-58) were included in the study. Plethysmographic signal amplitudes were evaluated at different temperatures (47, 45, 43, 40, 35, 20, 15, 13, 11 and 9-degrees-C) under standardized conditions, using digital strain-gauge plethysmographic (Perivein Janssen). Reproducibility was assessed by repetition in the same subject of six digital plethysmography signal measurements at 45-degrees-C performed at different times and days. Clinical tolerance was estimated according to an analogue scale. Results. Maximal warm amplitude was obtained at 45-degrees-C and maximal vasoconstriction at 13-degrees-C. The thermal test was well tolerated for the temperature range between 11 and 45-degrees-C. Reproducibility of the measurements was satisfactory. Conclusions. 45-degrees-C is the nonnociceptive reproducible vasoparalyzing reference temperature, allowing measurement of maximal digital circulatory capacities. 11-degrees-C should be adopted as the optimal vasoconstriction temperature for performance of a cold test (J Mal Vasc 1994; 19: pages 195-198).
引用
收藏
页码:195 / 198
页数:4
相关论文
共 50 条
  • [31] Performance of Treated Soft Clay with Nano-Modified Cementitious Binders at Reference and Cold Temperatures
    A. Eissa
    A. M. Yasien
    M. T. Bassuoni
    M. Alfaro
    International Journal of Geosynthetics and Ground Engineering, 2022, 8
  • [32] Performance of Treated Soft Clay with Nano-Modified Cementitious Binders at Reference and Cold Temperatures
    Eissa, A.
    Yasien, A. M.
    Bassuoni, M. T.
    Alfaro, M.
    INTERNATIONAL JOURNAL OF GEOSYNTHETICS AND GROUND ENGINEERING, 2022, 8 (05)
  • [33] Determination of Osteopenia in Children on Digital Radiography Compared with a DEXA Reference Standard
    Mulugeta, Philipose Getachew
    Jordanov, Martin
    Hernanz-Schulman, Marta
    Yu, Chang
    Kan, J. Herman
    ACADEMIC RADIOLOGY, 2011, 18 (06) : 722 - 725
  • [34] Determination of critical pitting temperatures by calcium chloride test, results of round-robin test
    Werner, H.
    Rommerskirchen, I.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2007, 58 (10): : 767 - 773
  • [35] DIGITAL PLETHYSMOGRAPHY FOR INVESTIGATION OF HEMORHEOLOGIC AND HEMODYNAMIC COMPONENTS OF AN ACROSYNDROME
    DEFAUCAL, P
    PLANCHON, B
    BOUDARD, D
    PELTIER, P
    BARRIER, J
    GROLLEAU, JY
    JOURNAL DES MALADIES VASCULAIRES, 1986, 11 (04) : 356 - 361
  • [36] COLD TEMPERATURES AND SKIN
    BEYLOT, C
    DOUTRE, MS
    BIOULAC, P
    REVUE DU PRATICIEN, 1979, 29 (18): : 1509 - 1513
  • [37] FUNCTIONAL SEGMENTAL PLETHYSMOGRAPHY - A NEW VENOUS FUNCTION TEST
    SAKAGUCHI, S
    TOMITA, T
    ENDO, I
    ISHITOBI, K
    JOURNAL OF CARDIOVASCULAR SURGERY, 1968, 9 (01): : 87 - +
  • [38] TENSILE TEST-RESULTS OF STAINLESS AUSTENITIC COLD STRIPS AT HIGH-TEMPERATURES
    MICHEL, KH
    MOZEK, HM
    MULDERS, H
    STAHL UND EISEN, 1985, 105 (05): : 251 - 256
  • [39] Relation between dorsal and palmar hand skin temperatures during a cold stress test
    Leijon-Sundqvist, K.
    Tegner, Y.
    Olsson, F.
    Karp, K.
    Lehto, N.
    JOURNAL OF THERMAL BIOLOGY, 2017, 66 : 87 - 92
  • [40] Determination of Spherical Test Mass Kinematics with Modular Gravitational Reference Sensor
    Conklin, John W.
    Allen, Graham
    Sun, Ke-Xun
    DeBra, Daniel B.
    JOURNAL OF GUIDANCE CONTROL AND DYNAMICS, 2008, 31 (06) : 1700 - 1707