PERFORMANCE OF POSTLINGUISTICALLY DEAF ADULTS WITH THE WEARABLE SPEECH PROCESSOR (WSP III) AND MINI SPEECH PROCESSOR (MSP) OF THE NUCLEUS MULTIELECTRODE COCHLEAR IMPLANT

被引:122
|
作者
SKINNER, MW
HOLDEN, LK
HOLDEN, TA
DOWELL, RC
SELIGMAN, PM
BRIMACOMBE, JA
BEITER, AL
机构
[1] UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
[2] COCHLEAR PTY LTD,LANE COVE,NSW,AUSTRALIA
[3] COCHLEAR CORP,ENGLEWOOD,CO
来源
EAR AND HEARING | 1991年 / 12卷 / 01期
关键词
D O I
10.1097/00003446-199102000-00002
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Seven postlinguistically deaf adults implanted with the Nucleus Multi-Electrode Cochlear Implant participated in an evaluation of speech perception performance with three speech processors: the Wearable Speech Process (WSP III), a prototype of the Mini Speech Processor, and the Mini Speech Processor. The first experiment was performed with the prototype and Wearable Speech Processor both programmed using the F0F1F2 speech coding strategy. The second experiment compared performance with the Mini Speech Processor programmed with the Multi-Peak speech coding strategy and the Wearable Speech Processor programmed with the F0F1F2 speech coding strategy. Performance was evaluated in the sound-only condition using recorded speech tests presented in quiet and in noise. Questionnaires and informal reports provided information about use in everyday life. In experiment I, there was no significant difference in performance using the Wearable Speech Processor and prototype on any of the tests. Nevertheless, six out of seven subjects preferred the prototype for use in everyday life. In experiment II, performance on open-set tests in quiet and noise was significantly higher with the Mini Speech Processor (Multi-Peak speech coding strategy) than with the Wearable Speech Processor. Subjects reported an increase in their ability to communicate with other people using the Mini Speech Processor (Multi-Peak speech coding strategy) compared with the Wearable Speech Processor in everyday life.
引用
收藏
页码:3 / 22
页数:20
相关论文
共 50 条
  • [41] WEARABLE DIGITAL SPEECH PROCESSOR FOR COCHLEAR IMPLANTS USING A TMS320C25
    DILLIER, N
    SENN, C
    SCHLATTER, T
    STOCKLI, M
    UTZINGER, U
    ACTA OTO-LARYNGOLOGICA, 1990, : 120 - 127
  • [42] Converted and Upgraded Maps Programmed in the Newer Speech Processor for the First Generation of Multichannel Cochlear Implant
    de Matos Magalhaes, Ana Tereza
    Valeria Schmidt Goffi-Gomez, M.
    Hoshino, Ana Cristina
    Tsuji, Robinson Koji
    Bento, Ricardo Ferreira
    Brito, Rubens
    OTOLOGY & NEUROTOLOGY, 2013, 34 (07) : 1193 - 1200
  • [43] A Speech Processor for Cochlear Implant using a Simple Dual Path Nonlinear Model of Basilar Membrane
    Kim, K. H.
    Choi, S. J.
    Kim, J. H.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 257 - +
  • [44] Cochlear implant speech processor placement and compression effects on sound sensitivity and interaural level difference
    Ricketts, Todd
    Grantham, D. Wesley
    D'Haese, Patrick
    Edwards, Jason
    Barco, Amy
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2006, 17 (02) : 133 - 140
  • [45] EVALUATION OF A PORTABLE 2-MICROPHONE ADAPTIVE BEAMFORMING SPEECH PROCESSOR WITH COCHLEAR IMPLANT PATIENTS
    VANHOESEL, RJM
    CLARK, GM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (04): : 2498 - 2503
  • [46] Speech discrimination scores of postlingually deaf adults implanted with the Combi 40 cochlear implant
    Gstoettner, WK
    Hamzavi, J
    Baumgartner, WD
    UPDATES IN COCHLEAR IMPLANTATION, 2000, 57 : 323 - 326
  • [47] Speech discrimination scores of postlingually deaf adults implanted with the Combi 40 cochlear implant
    Gstoettner, WK
    Hamzavi, J
    Baumgartner, WD
    ACTA OTO-LARYNGOLOGICA, 1998, 118 (05) : 640 - 645
  • [48] Effect of Different Signal-Processing Options on Speech-in-Noise Recognition for Cochlear Implant Recipients with the Cochlear CP810 Speech Processor
    Potts, Lisa G.
    Kolb, Kelly A.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2014, 25 (04) : 367 - 379
  • [49] ACOUSTIC PARAMETERS MEASURED BY A FORMANT-ESTIMATING SPEECH PROCESSOR FOR A MULTIPLE-CHANNEL COCHLEAR IMPLANT
    BLAMEY, PJ
    DOWELL, RC
    CLARK, GM
    SELIGMAN, PM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1987, 82 (01): : 38 - 47
  • [50] EXPERIENCE WITH THE COCHLEAR MINIATURE SPEECH PROCESSOR IN ADULTS AND CHILDREN TOGETHER WITH A COMPARISON OF UNIPOLAR AND BIPOLAR MODES
    LEHNHARDT, E
    GNADEBERG, D
    BATTMER, RD
    VONWALLENBERG, E
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1992, 54 (06): : 308 - 313