PERFORMANCE OF POSTLINGUISTICALLY DEAF ADULTS WITH THE WEARABLE SPEECH PROCESSOR (WSP III) AND MINI SPEECH PROCESSOR (MSP) OF THE NUCLEUS MULTIELECTRODE COCHLEAR IMPLANT

被引:122
|
作者
SKINNER, MW
HOLDEN, LK
HOLDEN, TA
DOWELL, RC
SELIGMAN, PM
BRIMACOMBE, JA
BEITER, AL
机构
[1] UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
[2] COCHLEAR PTY LTD,LANE COVE,NSW,AUSTRALIA
[3] COCHLEAR CORP,ENGLEWOOD,CO
来源
EAR AND HEARING | 1991年 / 12卷 / 01期
关键词
D O I
10.1097/00003446-199102000-00002
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Seven postlinguistically deaf adults implanted with the Nucleus Multi-Electrode Cochlear Implant participated in an evaluation of speech perception performance with three speech processors: the Wearable Speech Process (WSP III), a prototype of the Mini Speech Processor, and the Mini Speech Processor. The first experiment was performed with the prototype and Wearable Speech Processor both programmed using the F0F1F2 speech coding strategy. The second experiment compared performance with the Mini Speech Processor programmed with the Multi-Peak speech coding strategy and the Wearable Speech Processor programmed with the F0F1F2 speech coding strategy. Performance was evaluated in the sound-only condition using recorded speech tests presented in quiet and in noise. Questionnaires and informal reports provided information about use in everyday life. In experiment I, there was no significant difference in performance using the Wearable Speech Processor and prototype on any of the tests. Nevertheless, six out of seven subjects preferred the prototype for use in everyday life. In experiment II, performance on open-set tests in quiet and noise was significantly higher with the Mini Speech Processor (Multi-Peak speech coding strategy) than with the Wearable Speech Processor. Subjects reported an increase in their ability to communicate with other people using the Mini Speech Processor (Multi-Peak speech coding strategy) compared with the Wearable Speech Processor in everyday life.
引用
收藏
页码:3 / 22
页数:20
相关论文
共 50 条
  • [31] Cochlear implant speech processor frequency allocations may influence pitch perception
    Reiss, Lina A. J.
    Gantz, Bruce J.
    Turner, Christopher W.
    OTOLOGY & NEUROTOLOGY, 2008, 29 (02) : 160 - 167
  • [32] A SPEECH PROCESSOR WITH LATERAL INHIBITION FOR AN 8 CHANNEL COCHLEAR IMPLANT AND ITS EVALUATION
    IFUKUBE, T
    WHITE, RL
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (11) : 876 - 882
  • [33] Application of stapedius muscle reflex measurement in cochlear implant speech processor fitting
    Lorens, A
    Piotrowska, A
    Sliwa, L
    Walkowiak, A
    Skarzynski, H
    Wasowski, A
    6TH WORLD MULTICONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL XIII, PROCEEDINGS: CONCEPTS AND APPLICATIONS OF SYSTEMICS, CYBERNETICS AND INFORMATICS III, 2002, : 502 - 504
  • [34] Auditory and Speech Performance in Deaf Children With Deaf Parents After Cochlear Implant
    Park, Ga Young
    Moon, Il Joon
    Kim, Eun Yeon
    Chung, Eun-wook
    Cho, Yang-Sun
    Chung, Won-Ho
    Hong, Sung Hwa
    OTOLOGY & NEUROTOLOGY, 2013, 34 (02) : 233 - 238
  • [35] Verbesserung der Sprachverständlichkeit durch neuen Cochlear-Implant-SprachprozessorImproving speech comprehension using a new cochlear implant speech processor
    J. Müller-Deile
    T. Kortmann
    U. Hoppe
    H. Hessel
    A. Morsnowski
    HNO, 2009, 57 (6) : 567 - 574
  • [36] Financial Benefits of the Early Fitting of a Cochlear Implant Speech Processor: Assessment of the Direct Cost
    Hajr, Eman A.
    Almuhawas, Fida A.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (09)
  • [37] Simulation of ASIC/FPGA Cochlear Implant Speech Processor with SIMULINK and Modelsim Cosimulation Method
    Zhao, Haichen
    Mai, Songping
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [38] SPEECH PROCESSOR WITH LATERAL INHIBITION FOR AN EIGHT CHANNEL COCHLEAR IMPLANT AND ITS EVALUATION.
    Ifukube, Tohru
    White, Robert L.
    IEEE Transactions on Biomedical Engineering, 1987, BME-34 (11) : 876 - 882
  • [39] Emotional and analytic music perception in cochlear implant users after optimizing the speech processor
    Rosslau, Ken
    Spreckelmeyer, Katja N.
    Saalfeld, Hilke
    Westhofen, Martin
    ACTA OTO-LARYNGOLOGICA, 2012, 132 (01) : 64 - 71
  • [40] SPEECH UNDERSTANDING IN NOISE PROVIDED BY A SIMULATED COCHLEAR IMPLANT PROCESSOR BASED ON MATCHING PURSUIT
    Kressner, Abigail A.
    Rozell, Christopher J.
    2013 IEEE WORKSHOP ON APPLICATIONS OF SIGNAL PROCESSING TO AUDIO AND ACOUSTICS (WASPAA), 2013,