RADON MONITORING WITH PLASTIC DETECTORS IN EARTHQUAKE PREDICTION

被引:0
|
作者
KLEIS, T [1 ]
ENGE, W [1 ]
WOITH, H [1 ]
机构
[1] UNIV KIEL,INST GEOPHYS,W-2300 KIEL 1,GERMANY
来源
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Since 1984 a German-Turkish co-operation on earthquake prediction has existed at the North Anatolian fault zone in Turkey. Besides investigations on other parameters, changes in radon concentration are observed. The cellulose nitrate "Kodak LR115 Type II pelliculable" from Kodak-Pathe, France, and the 300-mu-m thick allyl diglycol carbonate CR-39 from Pershore Mouldings, U.K., are used in recording alpha-particles from radon and its daughter isotopes. The etching behaviour of both detectors has been measured. For LR115 an etchant-creeping effect at the boundary layer between the 13.5-mu-m CB-detector and the supporting 99.5-mu-m polyester base was observed. Based on these results a theoretical calculation of the so-called "sensitive volumes" was carried out. The most important result was the calculation of the Rn-sensitivities for both detectors. The calculated LR115/CR-39 sensitivity ratio was found to be equal to the measured track density ratioS D(CR-39)/D(LR115) = 2.14 +/- 0.81. Moreover, we found that the etching behaviour of LR115 is different from that of "Kodak CA 80-15"; this was formerly believed to be the same because the same raw cellulose nitrate material was involved in both cases.
引用
收藏
页码:495 / 503
页数:9
相关论文
共 50 条
  • [31] Radon exhalation rate in building materials using plastic track detectors
    Amrani, D
    Cherouati, DE
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 242 (02) : 269 - 271
  • [32] The study of indoor radon in the urban dwellings using plastic track detectors
    M. Shakir Khan
    M. Zubair
    Deepak Verma
    A. H. Naqvi
    Ameer Azam
    M. K. Bhardwaj
    Environmental Earth Sciences, 2011, 63 : 279 - 282
  • [33] Radon dosimetry in typical Indian dwellings using plastic track detectors
    Kant, K
    Upadhyay, SB
    Sharma, GS
    Chakarvart, SK
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (02) : 187 - 191
  • [34] A PLASTIC-BAG SAMPLER FOR PASSIVE RADON MONITORING
    TOMMASINO, L
    CHEROUATI, DE
    SEIDEL, JL
    MONNIN, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 681 - 684
  • [35] RADON MONITORING WITH SOLID-STATE NUCLEAR TRACK DETECTORS
    STEYN, A
    STRYDOM, R
    HEALTH PHYSICS, 1988, 54 (03): : 357 - 357
  • [36] Implementing soil radon detectors for long term continuous monitoring
    Galli, Gianfranco
    Cannelli, Valentina
    Nardi, Adriano
    Piersanti, Antonio
    APPLIED RADIATION AND ISOTOPES, 2019, 153
  • [37] RADON MONITORING WITH SOLID-STATE NUCLEAR TRACK DETECTORS
    STEYN, A
    STRYDOM, R
    SOUTH AFRICAN JOURNAL OF SCIENCE, 1987, 83 (09) : 571 - 571
  • [38] Radon Monitoring as the Earthquake Precursor in Fault Line in Western Turkey
    Sac, Muslim Murat
    Harmansah, Coskun
    Camgoz, Berkay
    Sozbilir, Hasan
    EKOLOJI, 2011, 20 (79): : 93 - 98
  • [39] RADON TRANSPORT IN THE EARTH - A TOOL FOR URANIUM EXPLORATION AND EARTHQUAKE PREDICTION
    FLEISCHER, RL
    MOGROCAMPERO, A
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 377 - 377
  • [40] METHOD FOR CONTINUOUS MEASUREMENT OF RADON IN WATER OF SPRINGS FOR EARTHQUAKE PREDICTION
    FRIEDMANN, H
    HERNEGGER, F
    GEOPHYSICAL RESEARCH LETTERS, 1978, 5 (07) : 565 - 568