RADON MONITORING WITH PLASTIC DETECTORS IN EARTHQUAKE PREDICTION

被引:0
|
作者
KLEIS, T [1 ]
ENGE, W [1 ]
WOITH, H [1 ]
机构
[1] UNIV KIEL,INST GEOPHYS,W-2300 KIEL 1,GERMANY
来源
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Since 1984 a German-Turkish co-operation on earthquake prediction has existed at the North Anatolian fault zone in Turkey. Besides investigations on other parameters, changes in radon concentration are observed. The cellulose nitrate "Kodak LR115 Type II pelliculable" from Kodak-Pathe, France, and the 300-mu-m thick allyl diglycol carbonate CR-39 from Pershore Mouldings, U.K., are used in recording alpha-particles from radon and its daughter isotopes. The etching behaviour of both detectors has been measured. For LR115 an etchant-creeping effect at the boundary layer between the 13.5-mu-m CB-detector and the supporting 99.5-mu-m polyester base was observed. Based on these results a theoretical calculation of the so-called "sensitive volumes" was carried out. The most important result was the calculation of the Rn-sensitivities for both detectors. The calculated LR115/CR-39 sensitivity ratio was found to be equal to the measured track density ratioS D(CR-39)/D(LR115) = 2.14 +/- 0.81. Moreover, we found that the etching behaviour of LR115 is different from that of "Kodak CA 80-15"; this was formerly believed to be the same because the same raw cellulose nitrate material was involved in both cases.
引用
收藏
页码:495 / 503
页数:9
相关论文
共 50 条
  • [21] RADON AND EARTHQUAKE PREDICTION IN INDIA - PRESENT STATUS
    VIRK, HS
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 483 - 494
  • [22] EXPERIENCES WITH RADON MEASUREMENTS FOR EARTHQUAKE PREDICTION AND LANDSLIDES
    HEINICKE, J
    KOCH, U
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 345 - 345
  • [23] PROPERTIES OF A SMALL RADON DIFFUSION CHAMBER WITH PLASTIC TRACK DETECTORS
    FRANK, AL
    BENTON, EV
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 379 - 379
  • [24] THE APPLICATION OF TRACK ETCH DETECTORS TO ENVIRONMENTAL RADON MONITORING
    ALTER, HW
    GINGRICH, JE
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1981, 39 : 111 - 111
  • [25] Geological fault exploration and earthquake prediction using radon
    Weng, PS
    RADON AND THORON IN THE HUMAN ENVIRONMENT, 1998, : 131 - 140
  • [26] METHOD FOR CONTINUOUS MEASUREMENT OF RADON IN GROUNDWATER FOR EARTHQUAKE PREDICTION
    NOGUCHI, M
    WAKITA, H
    JOURNAL OF GEOPHYSICAL RESEARCH, 1977, 82 (08): : 1353 - 1357
  • [27] Radon Monitoring in Soil Gas and Ground Water for Earthquake Prediction Studies in North West Himalayas, India
    Singh, Surinder
    Kumar, Arvind
    Bajwa, Bikramjit Singh
    Mahajan, Sandeep
    Kumar, Vinod
    Dhar, Sunil
    TERRESTRIAL ATMOSPHERIC AND OCEANIC SCIENCES, 2010, 21 (04): : 685 - 695
  • [28] Radon exhalation rate in building materials using plastic track detectors
    D. Amrani
    D. E. Cherouati
    Journal of Radioanalytical and Nuclear Chemistry, 1999, 242 : 269 - 271
  • [29] The study of indoor radon in the urban dwellings using plastic track detectors
    Khan, M. Shakir
    Zubair, M.
    Verma, Deepak
    Naqvi, A. H.
    Azam, Ameer
    Bhardwaj, M. K.
    ENVIRONMENTAL EARTH SCIENCES, 2011, 63 (02) : 279 - 282
  • [30] MEASUREMENT OF EXHALATION AND DIFFUSION PARAMETERS OF RADON IN SOLIDS BY PLASTIC TRACK DETECTORS
    SOMOGYI, G
    HAFEZ, AF
    HUNYADI, I
    TOTHSZILAGYI, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 701 - 704