Importance of electronic monitoring of intrapartum fetal heart rate as a predictor of neonatal outcomes

被引:0
|
作者
Fernanda Nozar, Maria [1 ]
Fiol, Veronica [1 ]
Martinez, Alma [1 ]
Enrique Pons, Jose [1 ]
Alonso, Justo [1 ]
Briozzo, Leonel [1 ]
机构
[1] Univ Republica, Fac Med, Minist Salud Publ, Ctr Hosp Pereira Rossell, Montevideo, Uruguay
来源
REVISTA MEDICA DEL URUGUAY | 2008年 / 24卷 / 02期
关键词
FETAL MONITORING - utilization; FETAL MONITORING - methods; LABOR; OBSTETRIC; HEART RATE - physiology; FETAL HYPOXIA - diagnosis;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: acute fetal distress is a metabolic disorder leading to hypoxia and acidosis that can result in serious lesions and even death. It is one of the main causes for neonatal morbimortality. Objective: to determine the relationship between the different fetal heart rate patterns corresponding to the suspicion of fetal hypoxia and neonatal results. Method: a prospective study (November 2001-August 2004) was conducted at the Maternity Service of the Pereira Rossell Hospital. Population: 183 patients were selected according to the following inclusion criteria: single pregnancy, cephalic presentation, labor and electronic monitoring of the fetal heart rate indicating fetal hypoxia. Pregnancy was interrupted in all emergency cases once diagnosis had been made. Results: average time for diagnosis at birth was 16.97 minutes, with a standard deviation of 7.7 minutes. Diagnostic patterns were: intra-partum deceleration 2 (106 cases, 58%), persistent bradychardia (79 cases, 43%), decrease in variability (12 cases, 6%), not promising (complex varied deceleration curves, 12 cases, 6%). Taking the acid-base state as a neonatal variable, the patterns that best predict the perinatal condition for pH levels below 7.10 is fetal bradychardia, representing positive predictive value of 31.6 (predictive value of the positive test). Taking into account the need to refer the newborn to the neonatal care unit, the pattern that best predicts this fact is a decrease in variability of 41.7(positive predictive value). Conclusion: the methods used in the study to diagnose intra-partum hypoxia have low positive predictive values.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 50 条
  • [41] Current status and recommendations for intrapartum monitoring of fetal heart rate
    Mechurova, A.
    Velebil, P.
    Hruban, L.
    Janku, P.
    CESKA GYNEKOLOGIE-CZECH GYNAECOLOGY, 2016, 81 (02): : 112 - 124
  • [42] Relationship Between Umbilical Cord Gas Values and Neonatal Outcomes Implications for Electronic Fetal Heart Rate Monitoring
    Johnson, Grace J.
    Salmanian, Bahram
    Denning, Stacie G.
    Belfort, Michael A.
    Sundgren, Nathan C.
    Clark, Steven L.
    OBSTETRICS AND GYNECOLOGY, 2021, 138 (03): : 366 - 373
  • [43] Relationship Between Umbilical Cord Gas Values and Neonatal Outcomes: Implications for Electronic Fetal Heart Rate Monitoring
    Devoe, Lawrence D.
    Britt, David W.
    Evans, Mark I.
    OBSTETRICS AND GYNECOLOGY, 2021, 138 (06): : 946 - +
  • [44] INTRAPARTUM FETAL HEART-RATE PATTERNS AND NEONATAL INTRAVENTRICULAR HEMORRHAGE
    RAYBURN, WF
    JOHNSON, MZ
    HOFFMAN, KL
    DONN, SM
    NELSON, RM
    AMERICAN JOURNAL OF PERINATOLOGY, 1987, 4 (02) : 98 - 101
  • [45] The Clinical Usefulness of the Continuous Electronic Fetal Monitoring with Computerized Analysis of Fetal Heart Rate Tracings in Intrapartum Assessment of Fetal Condition
    Rosner-Tenerowicz, A.
    Zimmer, M.
    18TH WORLD CONGRESS ON CONTROVERSIES IN OBSTETRICS, GYNECOLOGY & INFERTILITY (COGI), 2014, : 239 - 244
  • [46] ELECTRONIC MONITORING OF FETAL HEART-RATE AND DETERMINATION OF FETAL SCALP BLOOD-PH IN PREDICTION OF INTRAPARTUM FETAL DISTRESS
    DAI, MS
    FOX, H
    CHINESE MEDICAL JOURNAL, 1991, 104 (02) : 132 - 137
  • [47] Fetal pulse oximetry:: Correlation with intrapartum fetal heart rate patterns and neonatal outcome
    Tekin, Arzu
    Oezkan, Sebiha
    Caliskan, Eray
    Oezeren, Semih
    Corakci, Aydin
    Yuecesoy, Izzet
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2008, 34 (05) : 824 - 831
  • [48] IMPORTANCE OF FETAL HEART-RATE MONITORING
    MEYER, WC
    MINNESOTA MEDICINE, 1975, 58 (11) : 827 - 827
  • [49] COMPARISON OF INTRAPARTUM ELECTRONIC FETAL HEART-RATE MONITORING VERSUS INTERMITTENT AUSCULTATION IN DETECTING FETAL ACIDEMIA AT BIRTH
    VINTZILEOS, AM
    NOCHIMSON, DJ
    ANTSAKLIS, A
    VARVARIGOS, I
    GUZMAN, ER
    KNUPPEL, RA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 173 (04) : 1021 - 1024
  • [50] INTRAPARTUM ELECTRONIC FETAL MONITORING EFFICACY
    FRIBOURG, S
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 157 (04) : 1013 - 1014