Importance of electronic monitoring of intrapartum fetal heart rate as a predictor of neonatal outcomes

被引:0
|
作者
Fernanda Nozar, Maria [1 ]
Fiol, Veronica [1 ]
Martinez, Alma [1 ]
Enrique Pons, Jose [1 ]
Alonso, Justo [1 ]
Briozzo, Leonel [1 ]
机构
[1] Univ Republica, Fac Med, Minist Salud Publ, Ctr Hosp Pereira Rossell, Montevideo, Uruguay
来源
REVISTA MEDICA DEL URUGUAY | 2008年 / 24卷 / 02期
关键词
FETAL MONITORING - utilization; FETAL MONITORING - methods; LABOR; OBSTETRIC; HEART RATE - physiology; FETAL HYPOXIA - diagnosis;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: acute fetal distress is a metabolic disorder leading to hypoxia and acidosis that can result in serious lesions and even death. It is one of the main causes for neonatal morbimortality. Objective: to determine the relationship between the different fetal heart rate patterns corresponding to the suspicion of fetal hypoxia and neonatal results. Method: a prospective study (November 2001-August 2004) was conducted at the Maternity Service of the Pereira Rossell Hospital. Population: 183 patients were selected according to the following inclusion criteria: single pregnancy, cephalic presentation, labor and electronic monitoring of the fetal heart rate indicating fetal hypoxia. Pregnancy was interrupted in all emergency cases once diagnosis had been made. Results: average time for diagnosis at birth was 16.97 minutes, with a standard deviation of 7.7 minutes. Diagnostic patterns were: intra-partum deceleration 2 (106 cases, 58%), persistent bradychardia (79 cases, 43%), decrease in variability (12 cases, 6%), not promising (complex varied deceleration curves, 12 cases, 6%). Taking the acid-base state as a neonatal variable, the patterns that best predict the perinatal condition for pH levels below 7.10 is fetal bradychardia, representing positive predictive value of 31.6 (predictive value of the positive test). Taking into account the need to refer the newborn to the neonatal care unit, the pattern that best predicts this fact is a decrease in variability of 41.7(positive predictive value). Conclusion: the methods used in the study to diagnose intra-partum hypoxia have low positive predictive values.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 50 条
  • [31] A RANDOMIZED TRIAL OF INTRAPARTUM ELECTRONIC FETAL HEART-RATE MONITORING VERSUS INTERMITTENT AUSCULTATION
    SANDMIRE, HF
    OBSTETRICS AND GYNECOLOGY, 1993, 82 (05): : 880 - 880
  • [32] A RANDOMIZED TRIAL OF INTRAPARTUM ELECTRONIC FETAL HEART-RATE MONITORING VERSUS INTERMITTENT AUSCULTATION
    VINTZILEOS, AM
    ANTSAKLIS, A
    VARVARIGOS, I
    PAPAS, C
    SOFATZIS, I
    MONTGOMERY, JT
    OBSTETRICS AND GYNECOLOGY, 1993, 81 (06): : 899 - 907
  • [33] On Electronic Fetal Heart Rate Monitoring
    King, Tekoa L.
    Parer, Julian T.
    JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2011, 40 (06): : 669 - 671
  • [34] Electronic fetal heart rate monitoring
    Gandhi, Hina
    Kean, Lucy
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2008, 69 (07) : 388 - 391
  • [35] Intrapartum fetal heart rate monitoring in cases of cytomegalovirus infection
    Kaneko, M
    Sameshima, H
    Ikeda, T
    Ikenoue, T
    Minematsu, T
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (04) : 1257 - 1262
  • [36] ABDOMINAL ELECTROCARDIOGRAPHY IN INTRAPARTUM FETAL HEART-RATE MONITORING
    KARINIEMI, V
    ROSTI, J
    JOURNAL OF PERINATAL MEDICINE, 1986, 14 (04) : 263 - 266
  • [37] Intrapartum Fetal Heart Rate Monitoring: A Standardized Approach to Management
    Miller, David A.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2011, 54 (01): : 22 - 27
  • [38] Intrapartum fetal heart rate monitoring: Rationalise, refine or replace?
    Crouch, Catherine
    Seeho, Sean
    Morris, Jonathan
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2024, 64 (01): : 77 - 79
  • [39] The limits of electronic fetal heart rate monitoring in the prevention of neonatal metabolic acidemia
    Clark, Steven L.
    Hamilton, Emily F.
    Garite, Thomas J.
    Timmins, Audra
    Warrick, Philip A.
    Smith, Samuel
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2017, 216 (02) : 163.e1 - 163.e6
  • [40] Fetal Heart Rate Patterns as a predictor of Neonatal Hypercarbia
    Bailey, Erin
    Frolova, Antonia
    Lopez, Julia
    Raghuraman, Nandini
    Macones, George
    Cahill, Alison
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2019, 220 (01) : S499 - S499