Simplified design concept for slender masonry walls

被引:3
|
作者
Graubner, Carl-Alexander [1 ]
Foerster, Valentin [2 ]
机构
[1] KHP Konig & Heunisch Planungsgesells mbH & Co KG, Stresemannallee 30, D-60596 Frankfurt, Germany
[2] Tech Univ Darmstadt, Inst Massivbau, D-64287 Darmstadt, Germany
关键词
unreinforced masonry; load capacity; buckling; creep; design proposal;
D O I
10.1002/dama.201500680
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The verification of safety against buckling of unreinforced -masonry walls according to the accurate design procedure of EN 1996-1-1 Appendix G is based on semi-empirical approaches, which do not always realistically describe the load-bearing behaviour. This statement is also supported by an objection of the country Denmark concerning the load capacity function which is regulated in Appendix G. Using new findings about the effects of non-linear material behaviour in case of stability failure this article investigates fundamental questions about the buckling behaviour of masonry walls and transfers these into a simple practical structural design proposal. As a result, the load capacity function can be considerably simplified, the influence of creep can be integrated and the number of input parameters can be reduced.
引用
收藏
页码:417 / 426
页数:10