Simplified design concept for slender masonry walls

被引:3
|
作者
Graubner, Carl-Alexander [1 ]
Foerster, Valentin [2 ]
机构
[1] KHP Konig & Heunisch Planungsgesells mbH & Co KG, Stresemannallee 30, D-60596 Frankfurt, Germany
[2] Tech Univ Darmstadt, Inst Massivbau, D-64287 Darmstadt, Germany
关键词
unreinforced masonry; load capacity; buckling; creep; design proposal;
D O I
10.1002/dama.201500680
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The verification of safety against buckling of unreinforced -masonry walls according to the accurate design procedure of EN 1996-1-1 Appendix G is based on semi-empirical approaches, which do not always realistically describe the load-bearing behaviour. This statement is also supported by an objection of the country Denmark concerning the load capacity function which is regulated in Appendix G. Using new findings about the effects of non-linear material behaviour in case of stability failure this article investigates fundamental questions about the buckling behaviour of masonry walls and transfers these into a simple practical structural design proposal. As a result, the load capacity function can be considerably simplified, the influence of creep can be integrated and the number of input parameters can be reduced.
引用
收藏
页码:417 / 426
页数:10
相关论文
共 50 条
  • [21] In-plane response of slender walls made of calcium silicate brick and element masonry
    Esposito, R.
    Ravenshorst, G.J.P.
    Rots, J.G.
    Heron, 2021, 66 (01): : 37 - 60
  • [22] DESIGN PROCEDURES FOR NONREINFORCED CONCRETE MASONRY WALLS
    SOLTIS, LA
    PLANT ENGINEERING, 1977, 31 (19) : 213 - 217
  • [23] DESIGN OF REINFORCED MASONRY WALLS FOR SEISMIC ACTIONS
    TOMAZEVIC, M
    LUTMAN, M
    BRICK AND BLOCK MASONRY, VOLS 1-3, 1988, : 800 - 810
  • [24] Interior insulation of masonry walls - Assessment and design
    Steskens, P.
    Loncour, X.
    Roels, S.
    Vereecken, E.
    CONTRIBUTIONS TO BUILDING PHYSICS, 2013, : 791 - 798
  • [25] Design of steel lintels supporting masonry walls
    Hardy, SJ
    ENGINEERING STRUCTURES, 2000, 22 (06) : 597 - 604
  • [26] STRESS REDUCTION DESIGN FACTORS FOR MASONRY WALLS
    COLVILLE, J
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1979, 105 (10): : 2035 - 2051
  • [27] DESIGN OF LOAD-BEARING MASONRY WALLS
    ZAIDI, STH
    CIVIL ENGINEERING, 1980, 50 (11): : 63 - 65
  • [28] Modelling micro-structure aspects of masonry walls by a simplified approach
    Casolo, S
    Peña, F
    STRUCTURAL STUDIES, REPAIRS AND MAINTENANCE OF HERITAGE ARCHITECTURE VIII, 2003, 16 : 337 - 346
  • [29] Influence of cavity dimension on the stability of eccentrically loaded slender unreinforced masonry hollow walls
    Lu, Mu
    Schultz, Arturo E.
    Stolarski, Henryk K.
    CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (12) : 4444 - 4453
  • [30] Simplified analytical models for partially grouted reinforced masonry shear walls
    Al-Ahdal, Abdulelah
    Aly, Nader
    Galal, Khaled
    ENGINEERING STRUCTURES, 2022, 252