Simplified design concept for slender masonry walls

被引:3
|
作者
Graubner, Carl-Alexander [1 ]
Foerster, Valentin [2 ]
机构
[1] KHP Konig & Heunisch Planungsgesells mbH & Co KG, Stresemannallee 30, D-60596 Frankfurt, Germany
[2] Tech Univ Darmstadt, Inst Massivbau, D-64287 Darmstadt, Germany
关键词
unreinforced masonry; load capacity; buckling; creep; design proposal;
D O I
10.1002/dama.201500680
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The verification of safety against buckling of unreinforced -masonry walls according to the accurate design procedure of EN 1996-1-1 Appendix G is based on semi-empirical approaches, which do not always realistically describe the load-bearing behaviour. This statement is also supported by an objection of the country Denmark concerning the load capacity function which is regulated in Appendix G. Using new findings about the effects of non-linear material behaviour in case of stability failure this article investigates fundamental questions about the buckling behaviour of masonry walls and transfers these into a simple practical structural design proposal. As a result, the load capacity function can be considerably simplified, the influence of creep can be integrated and the number of input parameters can be reduced.
引用
收藏
页码:417 / 426
页数:10
相关论文
共 50 条
  • [1] Design of slender shear connected masonry cavity walls
    Wang, R
    Elwi, AE
    Hatzinikolas, MA
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1997, 24 (05) : 808 - 818
  • [2] A SIMPLIFIED FINITE-ELEMENT METHOD FOR DESIGN OF HOLLOW BLOCK MASONRY WALLS
    GANESAN, TP
    RAMAMURTHY, K
    BRICK AND BLOCK MASONRY, VOLS 1-3, 1988, : 1437 - 1446
  • [3] Behavior of slender, posttensioned masonry walls under transverse loading
    Popehn, Jennifer R. Bean
    Schultz, Arturo E.
    Drake, Christopher R.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2007, 133 (11): : 1541 - 1550
  • [4] Influence of transverse loading on the stability of slender unreinforced masonry walls
    Popehn, Jennifer R. Bean
    Schultz, Arturo E.
    Lu, Mu
    Stolarski, Henryk K.
    Ojard, Nels J.
    ENGINEERING STRUCTURES, 2008, 30 (10) : 2830 - 2839
  • [5] Eurocode 6 Part 3 - Design of masonry walls according to the simplified calculation method
    Hauer, Markus
    MAUERWERK, 2012, 16 (03) : 121 - 126
  • [6] THE DESIGN OF PLAIN MASONRY WALLS
    OJINAGA, J
    TURKSTRA, CJ
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1980, 7 (02) : 233 - 242
  • [7] Seismic behaviour and design code provisions for predicting the capacity of ductile slender reinforced masonry shear walls
    Robazza, B. R.
    Brzev, S.
    Yang, T. Y.
    Elwood, K. J.
    Anderson, D. L.
    McEwen, B.
    ENGINEERING STRUCTURES, 2020, 222
  • [8] Simplified verification method for unreinforced -masonry shear walls
    Graubner, Carl-Alexander
    Mueller, Dominik
    MAUERWERK, 2019, 23 (05) : 300 - 305
  • [9] Verification of second-order effects in slender reinforced masonry walls
    Dona, Marco
    Tecchio, Giovanni
    da Porto, Francesca
    MATERIALS AND STRUCTURES, 2018, 51 (03)
  • [10] STRENGTH TESTS ON SLENDER PLAIN BLOCK MASONRY WALLS WITH VENEER WYTHES
    NEIS, VV
    GHOSH, S
    HATZINIKOLAS, M
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1991, 18 (05) : 739 - 748