NONINVASIVE ESTIMATION OF CORONARY FLOW RESERVE BY TRANSESOPHAGEAL DOPPLER MEASUREMENT OF CORONARY SINUS FLOW

被引:28
|
作者
SIOSTROZONEK, P
KRANZ, A
HEINZ, G
RODLER, S
GOSSINGER, H
KREINER, G
STUMPFLEN, A
ZEHETGRUBER, M
SCHWARZ, M
WEBER, H
机构
[1] 2nd Department of Medicine, Division of Cardiology, University of Vienna, A-1090 Vienna
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1993年 / 72卷 / 17期
关键词
D O I
10.1016/0002-9149(93)90314-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Currently available methods for the measurement of coronary flow reserve (CFR) are invasive and time-consuming, and need adequate laboratory equipment and staff.1-4 Furthermore, most of these methods are limited by various methodologic problems.5,6 Transesophageal echocardiography enables visualization of the distal coronary sinus in most patients. Accordingly, we investigated the ability of transesophageal echocardiography to calculate CFR by Doppler measurement of coronary sinus flow (CSF) at rest and after dipyridamole administration. © 1993.
引用
收藏
页码:1334 / 1337
页数:4
相关论文
共 50 条
  • [31] Measurement of coronary flow reserve in children by transthoracic Doppler echocardiography
    Noto, N
    Karasawa, K
    Ayusawa, M
    Misawa, M
    Sumitomo, N
    Okada, T
    Harada, K
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (12): : 1638 - &
  • [32] DOPPLER MEASUREMENT OF CORONARY FLOW RESERVE IN CARDIAC TRANSPLANT PATIENTS
    SHARMA, RK
    REDDY, HK
    VOELKER, DJ
    SINGH, VN
    SHAW, B
    FLOYD, B
    CLINICAL RESEARCH, 1993, 41 (03): : A640 - A640
  • [33] Validation of Doppler FloWire for measurement of coronary flow reserve in humans
    Dib, N
    Bajwa, T
    Shalev, Y
    Nesto, R
    Schmidt, DH
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 45 (04): : 382 - 385
  • [34] COMPARISON OF FLOW VELOCITY IN THE LEFT ANTERIOR DESCENDING CORONARY-ARTERY AND CORONARY FLOW RESERVE, BY INTRACORONARY DOPPLER FLOW WIRE AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    THAKER, KB
    KAWANISHI, D
    NARANG, YK
    RASHTIAN, M
    MEHRA, A
    ANTHONY, P
    CHANDRARATNA, N
    CIRCULATION, 1994, 90 (04) : 276 - 276
  • [35] Measurement of coronary sinus flow using transesophageal echocardiography undergoing coronary artery bypass grafting
    Toyota, S
    Amaki, Y
    ANESTHESIA AND ANALGESIA, 1998, 86 (2S):
  • [36] Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment
    Paweł Petkow Dimitrow
    Cardiovascular Ultrasound, 1 (1)
  • [37] Prognostic significance of coronary flow reserve assessed by MR flow measurement in the coronary sinus in patients with hypertrophic cardiomyopathy
    Yasuyuki Shiraishi
    Tatsuro Ito
    Masaki Ishida
    Motonori Nagata
    Kakuya Kitagawa
    Hiroshi Nakajima
    Kaoru Dohi
    Masaaki Ito
    Hajime Sakuma
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [38] CORONARY FLOW RESERVE BY DOPPLER WIRE IS NOT EQUIVALENT TO STENOTIC FLOW RESERVE
    LIEBERMAN, SM
    UNDEMIR, C
    SHAKNOVICH, A
    WILENTZ, JR
    FRIEDMAN, MS
    HIGGINS, J
    COHEN, NT
    MCCROSSAN, J
    MOSES, JW
    CIRCULATION, 1993, 88 (04) : 204 - 204
  • [39] EFFECTS OF VIABLE MYOCARDIUM ON CORONARY FLOW RESERVE - A STUDY BY TRANSESOPHAGEAL DOPPLER-ECHOCARDIOGRAPHY
    TANAKA, N
    YOSHIDA, K
    AKASAKA, T
    SHAKUDO, M
    MURO, T
    CIRCULATION, 1993, 88 (04) : 112 - 112
  • [40] Noninvasive quantification of myocardial blood flow and coronary flow reserve
    George A. Beller