Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment

被引:56
|
作者
Paweł Petkow Dimitrow
机构
[1] 2nd Department of Cardiology CMUJ,
关键词
coronary flow reserve; transthoracic Doppler echocardiography;
D O I
10.1186/1476-7120-1-4
中图分类号
学科分类号
摘要
This review focuses on transthoracic Doppler echocardiography as noninvasive method used to assess coronary flow reserve (CFR) in a wide spectrum of clinical settings. Transthoracic Doppler echocardiography is rapidly gaining appreciation as popular tool to measure CFR both in stenosed and normal epicardial coronary arteries (predominantly in left anterior descending coronary artery). Post-stenotic CFR measurement is helpful in: functional assessment of moderate stenosis, detection of significant or critical stenosis, monitoring of restenosis after revascularization. In the absence of stenosis in the epicardial coronary artery, decreased CFR enable to detect impaired microvascular vasodilatation in: reperfused myocardial infarct, arterial hypertension with or without left ventricular hypertrophy, diabetes mellitus, hypercholesterolemia, syndrome X, hypertrophic cardiomyopathy. In these diseases, noninvasive transthoracic Doppler echocardiography allows for serial CFR evaluations to explore the effect of various pharmacological therapies.
引用
收藏
相关论文
共 50 条
  • [1] Noninvasive assessment of coronary flow reserve with transthoracic signal-enhanced Doppler echocardiography
    Lambertz, H
    Tries, HP
    Stein, T
    Lethen, H
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (03) : 186 - 195
  • [2] Coronary Flow Velocity Reserve Assessment with Transthoracic Doppler Echocardiography
    Simova, Iana
    EUROPEAN CARDIOLOGY REVIEW, 2015, 10 (01) : 12 - 18
  • [3] Assessment of Coronary Flow Velocity Reserve by Noninvasive Transthoracic Doppler Echocardiography in Patients with Angiographically Normal Coronary Arteries
    杨娅
    Thomas BARTEL
    李治安
    Raimund ERBEL
    华中科技大学学报(医学英德文版), 2005, (05) : 590 - 593
  • [4] Assessment of coronary flow velocity reserve by noninvasive transthoracic doppler echocardiography in patients with angiographically normal coronary arteries
    Yang Ya
    Thomas Bartel
    Li Zhian
    Raimund Erbel
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2005, 25 (5): : 590 - 593
  • [5] Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the right coronary artery by transthoracic Doppler echocardiography: Comparison with intracoronary Doppler guidewire
    Ueno, Y
    Nakamura, Y
    Takashima, H
    Kinoshita, M
    Soma, A
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (10) : 1074 - 1079
  • [6] Assessment of coronary flow reserve with transthoracic Doppler echocardiography: Comparison with intracoronary Doppler method
    Kim, SM
    Shim, WJ
    Lim, HE
    Hwang, GS
    Song, WH
    Lim, DS
    Kim, YH
    Seo, HS
    Oh, DJ
    Ro, YM
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2000, 15 (02) : 139 - 145
  • [7] Usefulness of coronary flow reserve with transthoracic Doppler echocardiography
    Watanabe, Hiroyuki
    Yokoi, Yoshiaki
    Takeuchi, Kazuhide
    Daimon, Masao
    Takemoto, Kazushi
    Higashiue, Shinichi
    Yoshikawa, Junichi
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [8] Noninvasive assessment of coronary flow reserve by transthoracic Doppler echocardiography in a general referral population: experience on 957 patients
    Lowenstein, J
    Presti, C
    Tiano, C
    EUROPEAN HEART JOURNAL, 2001, 22 : 347 - 347
  • [9] Noninvasive assessment of coronary flow reserve by transthoracic digital color Doppler echocardiography with a high-frequency transducer
    Hozumi, T
    Yoshida, K
    Asami, Y
    Ogata, Y
    Kawamoto, T
    CIRCULATION, 1997, 96 (08) : 4000 - 4000
  • [10] Assessment of coronary flow reserve by adenosine transthoracic echocardiography: Validation with intracoronary Doppler
    Hildick-Smith, DJR
    Maryan, R
    Shapiro, LM
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (09) : 984 - 990