THE CONSTRUCTION, CALIBRATION AND USE OF LIQUID ION-EXCHANGER, ION-SELECTIVE, DOUBLE-BARRELLED MICROELECTRODES FOR MEASUREMENT OF INTRACELLULAR ION ACTIVITIES

被引:0
|
作者
LEADER, JP
机构
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:80 / 82
页数:3
相关论文
共 50 条
  • [31] CALIBRATION OF ION-SELECTIVE MICROELECTRODES FOR USE WITH HIGH-LEVELS OF INTERFERING IONS
    SALT, AN
    VORA, A
    JOURNAL OF NEUROSCIENCE METHODS, 1991, 38 (2-3) : 233 - 237
  • [32] Preparation of double-barreled ion-selective microelectrodes
    Li J.
    Xue L.
    Zhou Q.
    Huang L.
    Wang Z.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2021, 37 (16): : 24 - 30
  • [33] MEASUREMENT OF INTRACELLULAR CALCIUM-ION ACTIVITY WITH NEUTRAL EXCHANGER ION SENSITIVE MICROELECTRODES
    FOZZARD, HA
    CHAPMAN, RA
    FRIEDLANDER, IR
    CELL CALCIUM, 1985, 6 (1-2) : 57 - 68
  • [34] ANALYSIS AND PRESENTATION OF INTRACELLULAR MEASUREMENTS OBTAINED WITH ION-SELECTIVE MICROELECTRODES
    FRY, CH
    HALL, SK
    BLATTER, LA
    MCGUIGAN, JAS
    EXPERIMENTAL PHYSIOLOGY, 1990, 75 (02) : 187 - 198
  • [35] Donnan Failure of Ion-Selective Electrodes with Hydrophilic High-Capacity Ion-Exchanger Membranes
    Ogawara, Shogo
    Carey, Jesse L., III
    Zou, Xu U.
    Bühlmann, Philippe
    ACS SENSORS, 2016, 1 (01): : 95 - 101
  • [36] ASSESSMENT OF POTASSIUM ZINC FERROCYANIDE AS AN ALKALI-METAL ION-EXCHANGER IN ION-SELECTIVE ELECTRODES
    FOGG, AG
    PATHAN, AS
    BURNS, DT
    ANALYTICAL LETTERS, 1974, 7 (8-9) : 539 - 543
  • [37] SOME PROPERTIES OF SULFATE ION-SELECTIVE PVC MEMBRANES BASED ON A NEUTRAL CARRIER AND ION-EXCHANGER
    SMIRNOVA, AL
    TARASEVITCH, VN
    RAKHMANKO, EM
    SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3): : 392 - 395
  • [38] SODIUM-SELECTIVE LIQUID ION-EXCHANGER MICRO-ELECTRODES FOR INTRACELLULAR MEASUREMENTS
    ODOHERTY, J
    GARCIADIAZ, JF
    ARMSTRONG, WM
    SCIENCE, 1979, 203 (4387) : 1349 - 1351
  • [39] DOUBLE BARRELLED K+ SELECTIVE LIQUID ION-EXCHANGER MICROELECTRODE DESIGNED FOR A CONTINUOUS MEASUREMENT OF LOCAL EXTRACELLULAR K+ ACTIVITY IN BRAIN CORTEX IN ANIMALS
    ASTRUP, J
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1975, 35 : 33 - 33
  • [40] CHLORIDE AND POTASSIUM ACTIVITIES IN LUMINAL FLUID OF TURTLE THYROID FOLLICLES AS DETERMINED BY SELECTIVE ION-EXCHANGER MICROELECTRODES
    CHOW, SY
    KUNZE, D
    BROWN, AM
    WOODBURY, DM
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1970, 67 (02) : 998 - &