THE ADVANCED PHOTON SOURCE-X-RAY TRANSMITTING BEAM-POSITION-MONITOR TESTS AT THE NATIONAL SYNCHROTRON LIGHT-SOURCE X-25 BEAMLINE

被引:10
|
作者
SHU, D
COLLINS, JT
BARRAZA, J
KUZAY, TM
机构
[1] Experimental Facilities Division, Advanced Photon Source, Argonne National Laboratory, Argonne
关键词
D O I
10.1016/0168-9002(94)91951-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A synthetic-diamond-based X-ray transmitting beam-position monitor has been studied using focused white beam at the National Synchrotron Light Source X-25 wiggler beamline. of particular interest are the possibilities to design an integral window and filter/photon beam-position monitor for the Advanced Photon Source high-heat-flux insertion-device beamlines. The preliminary measurements were taken using two synthetic-diamond blade samples with different thicknesses and cooling configurations. The monitor (consisting of a vacuum vessel, an ion pump, a water-cooling base, a blade mounting block, and electric feedthroughs) was mounted on a three-dimensional (x, y, phi) stepping-motor-driven stage with a 0.064-mum stepping size and a 0.1-mum linear encoder resolution. An infrared camera system was used to monitor and record the diamond blade surface temperature field through a sapphire window and test results are presented.
引用
收藏
页码:577 / 580
页数:4
相关论文
共 50 条
  • [1] AN X-RAY-SCATTERING BEAM LINE AT THE NATIONAL SYNCHROTRON LIGHT-SOURCE
    KVICK, A
    KOETZLE, TF
    HASTINGS, JB
    THOMLINSON, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (1-2): : 285 - 285
  • [2] ADVANCED LIGHT-SOURCE (ALS) BEAM POSITION MONITOR
    HINKSON, J
    JOHNSTON, J
    KO, I
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 1507 - 1509
  • [3] THE NAVAL RESEARCH LABORATORYS NEW HARD X-RAY BEAMLINE AT THE NATIONAL SYNCHROTRON LIGHT-SOURCE
    KIRKLAND, JP
    ELAM, WT
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1709 - 1711
  • [4] Photon beam position monitor for Hefei light source undulator beamline
    Sun, Bao-Gen
    Gu, Li-Ming
    Ma, Tian-Ji
    Lu, Ping
    Wang, Ji-Gang
    Tang, Lei-Lei
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2009, 43 (SUPPL. 1): : 172 - 176
  • [5] HIGH-BRIGHTNESS BEAMLINE FOR X-RAY SPECTROSCOPY AT THE ADVANCED LIGHT-SOURCE
    PERERA, RCC
    JONES, G
    LINDLE, DW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1745 - 1747
  • [6] OPTICAL DESIGN AND PERFORMANCE OF THE X25 HYBRID WIGGLER BEAM LINE AT THE NATIONAL SYNCHROTRON LIGHT-SOURCE
    BERMAN, LE
    HASTINGS, JB
    OVERSLUIZEN, T
    WOODLE, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 428 - 432
  • [7] THE NATIONAL SYNCHROTRON LIGHT-SOURCE VUV AND SOFT-X-RAY BEAM LINES - PERFORMANCE-CHARACTERISTICS
    KLAFFKY, RW
    HOWELLS, MR
    WILLIAMS, GP
    TAKACS, PZ
    GODEL, JB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (1-2): : 155 - 162
  • [8] Advanced photon source booster synchrotron beam position monitor upgrade and applications
    Sereno, NS
    Lenkszus, F
    Lill, RM
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 2435 - 2437
  • [9] A new soft x-ray photoemission microscopy beamline at the National Synchrotron Light Source
    Flege, J. I.
    Vescovo, E.
    Nintzel, G.
    Lewis, L. H.
    Hulbert, S.
    Sutter, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2): : 855 - 858
  • [10] Progress toward a hard x-ray insertion device beam position monitor at the Advanced Photon Source
    Decker, Glenn
    Den Hartog, P.
    Singh, O.
    Rosenbaum, Gerd
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 295 - +