Photon beam position monitor for Hefei light source undulator beamline

被引:0
|
作者
Sun, Bao-Gen [1 ]
Gu, Li-Ming [1 ]
Ma, Tian-Ji [1 ]
Lu, Ping [1 ]
Wang, Ji-Gang [1 ]
Tang, Lei-Lei [1 ]
机构
[1] National Synchrotron Radiation Laboratory, School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230029, China
来源
关键词
9;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:172 / 176
相关论文
共 50 条
  • [1] Application of Libera Photon in photon beam position measurement system at Hefei light source
    Gu, Li-Ming
    Sun, Bao-Gen
    Yang, Yong-Liang
    Lu, Ping
    Xiao, Yun-Yun
    Wang, Ji-Gang
    Tang, Lei-Lei
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2012, 46 (12): : 1512 - 1516
  • [2] Design study for an undulator photon beam position and profile monitor
    Hsu, IC
    Wang, CT
    Lai, PC
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 2047 - 2048
  • [3] Photon-beam-position Monitor in the PLS Diagnostic Beamline
    Kim, Changbum
    Yoon, Jong Chel
    Kim, Seung-nam
    Kim, Myong-jiu
    Kim, Hee Seob
    Ryu, Chun Kil
    Lee, Chae-soon
    Seo, In Denk
    Park, Chongdo
    Lee, Hae Cheol
    Hong, Man-soo
    Huang, Jung-Yun
    Han, Yeongjin
    Park, Jaehun
    Ko, In Soo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 56 (06) : 1981 - 1984
  • [4] Operational experience with the photon beam position monitor for undulator beamlines of Elettra
    Galimberti, A
    Borghes, R
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 584 - 587
  • [5] PHOTON-BEAM POSITION MONITOR FOR SSRL BEAMLINE-9
    CERINO, JA
    RABEDEAU, T
    BOWEN, W
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1646 - 1647
  • [6] Photon flux measurement of the soft X-ray beamline in Hefei Light Source
    Zhang, Y.X.
    Jiang, S.P.
    Zhang, X.Y.
    Wei, D.Y.
    Xu, S.G.
    He Jishu/Nuclear Techniques, 2001, 24 (07):
  • [7] First results of the novel photon beam position monitor for undulator beamlines of Elettra
    Galimberti, A
    Borghes, R
    Paolucci, G
    Presacco, R
    Paolicelli, G
    Stefani, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 221 - 225
  • [8] The beam position monitor of the BEAR beamline
    Giglia, A
    Mahne, N
    Pedio, M
    Nannarone, S
    Pelizzo, MG
    Naletto, G
    Zambolin, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06):
  • [9] V-coupling-blades beam position monitor for NSRL undulator source
    Cheng, X. C.
    Zhao, F. Y.
    Tian, Y. C.
    Xu, C. Y.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [10] THERMOMECHANICAL ANALYSIS OL THE WHITE-BEAM SLITS FOR AN UNDULATOR BEAMLINE AT THE ADVANCED PHOTON SOURCE
    NIAN, HLT
    SHU, D
    KUZAY, TM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1735 - 1737