LABORATORY EXAFS IN A DISPERSIVE MODE

被引:8
|
作者
BUSCHERT, R
GIARDINA, MD
MERLINI, A
BALERNA, A
MOBILIO, S
机构
[1] ISPRA ESTAB,COMMISS EUROPEAN COMMUNITIES,JOINT RES CTR,DIV PHYS,I-21020 ISPRA,ITALY
[2] IST NAZL FIS NUCL,LAB NAZL FRASCATI,I-00044 FRASCATI,ITALY
关键词
Spectrometers - Extended X ray absorption fine structure spectroscopy - Absorption spectra;
D O I
10.1107/S0021889887008641
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A laboratory dispersive mode spectrometer, capable of operating in either the analysing crystal transmission mode or a reflection mode, is described. Extended X-ray absorption fine structure (EXAFS) spectra of Re and ReO2, obtained in the transmission mode, compare favourably with those from a scanning spectrometer at a synchrotron source. Factors affecting resolution, intensity and background in this transmission mode are discussed. Experiments with asymmetric reflection geometries, which have shown both improved resolution for X-ray absorption near edge structure (XANES) and reduced collection times, are reported. Methods of reducing backgrounds due to multiple Bragg reflections and Compton scattering are proposed. © 1988, Wiley-Blackwell. All rights reserved.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [31] EXAFS MEASUREMENT WITH LABORATORY EQUIPMENT - PROBLEMS AND THEIR COUNTERMEASURES
    OKAMOTO, T
    YAMASHITA, S
    YAMAGUCHI, T
    WAKITA, H
    X-RAY SPECTROMETRY, 1990, 19 (01) : 15 - 21
  • [32] VARIABLE ROWLAND RADIUS LABORATORY EXAFS SYSTEM
    YACOBY, Y
    BRETTSCHNEIDER, M
    BEZALEL, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (04): : 588 - 592
  • [33] A DOUBLE CRYSTAL SPECTROMETER FOR LABORATORY EXAFS SPECTROSCOPY
    TOHJI, K
    UDAGAWA, Y
    PHYSICA B, 1989, 158 (1-3): : 332 - 334
  • [34] A STABLE IN-LABORATORY EXAFS MEASUREMENT SYSTEM
    ITO, M
    IWASAKI, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1983, 22 (02): : 357 - 360
  • [35] Scanning and energy dispersive EXAFS studies of nickel alkene oligomerisation catalysts
    Corker, JM
    Dent, AJ
    Evans, J
    Hagelstein, M
    Kambhampati, VL
    JOURNAL DE PHYSIQUE IV, 1997, 7 (C2): : 879 - 881
  • [36] Energy dispersive-EXAFS of Pd nucleation at a liquid/liquid interface
    Chang, S-Y
    Booth, S. G.
    Uehara, A.
    Mosselmans, J. F. W.
    Cibin, G.
    Pham, V-T
    Nataf, L.
    Dryfe, R. A. W.
    Schroeder, S. L. M.
    16TH INTERNATIONAL CONFERENCE ON X-RAY ABSORPTION FINE STRUCTURE (XAFS16), 2016, 712
  • [37] Ultrafast time resolved EXAFS spectroscopy using energy dispersive spectrometer
    Tomov, IV
    Oulianov, DA
    Rentzepis, PM
    X-RAY OPTICS DESIGN, PERFORMANCE, AND APPLICATIONS, 1999, 3773 : 216 - 221
  • [38] Development of Time-Resolved XAFS Instrumentation for Quick EXAFS and Energy-Dispersive EXAFS Measurements on Catalyst Systems
    Andrew J. Dent
    Topics in Catalysis, 2002, 18 : 27 - 35
  • [39] Development of time-resolved XAFS instrumentation for quick EXAFS and energy-dispersive EXAFS measurements on catalyst systems
    Dent, AJ
    TOPICS IN CATALYSIS, 2002, 18 (1-2) : 27 - 35
  • [40] DOUBLE-CRYSTAL SPECTROMETER FOR LABORATORY EXAFS SPECTROSCOPY
    TOHJI, K
    UDAGAWA, Y
    KAWASAKI, T
    MIENO, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (07): : 1127 - 1131