A laboratory dispersive mode spectrometer, capable of operating in either the analysing crystal transmission mode or a reflection mode, is described. Extended X-ray absorption fine structure (EXAFS) spectra of Re and ReO2, obtained in the transmission mode, compare favourably with those from a scanning spectrometer at a synchrotron source. Factors affecting resolution, intensity and background in this transmission mode are discussed. Experiments with asymmetric reflection geometries, which have shown both improved resolution for X-ray absorption near edge structure (XANES) and reduced collection times, are reported. Methods of reducing backgrounds due to multiple Bragg reflections and Compton scattering are proposed. © 1988, Wiley-Blackwell. All rights reserved.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [21] LABORATORY EXAFS SPECTROMETER FOR CATALYST STUDIES
    KHALID, S
    EMRICH, R
    DUJARI, R
    SHULTZ, J
    KATZER, JR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1982, 53 (01): : 22 - 33
  • [22] LABORATORY EXAFS SPECTROMETER, PRINCIPLES AND APPLICATIONS
    KAMPERS, FWH
    DUIVENVOORDEN, FBM
    VANZON, JBAD
    BRINKGREVE, P
    VIEGERS, MPA
    KONINGSBERGER, DC
    SOLID STATE IONICS, 1985, 16 (1-4) : 55 - 63
  • [23] Laboratory EXAFS using photographic method
    Joshi, S. K.
    Gaur, A.
    Johari, A.
    Shrivastava, B. D.
    14TH INTERNATIONAL CONFERENCE ON X-RAY ABSORPTION FINE STRUCTURE (XAFS14), PROCEEDINGS, 2009, 190
  • [24] DEVELOPMENT OF A LABORATORY EXAFS FACILITY.
    Tohji, Kazuyuki
    Udagawa, Yasuo
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes, 1983, 22 (05): : 882 - 885
  • [25] EXAFS SPECTROSCOPY OF SOME IRON(III) COMPOUNDS BY USE OF DISPERSIVE-TYPE IN-LABORATORY X-RAY SPECTROMETER
    NOMURA, M
    ASAKURA, K
    KAMINAGA, U
    MATSUSHITA, T
    KOHRA, K
    KURODA, H
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1982, 55 (12) : 3911 - 3914
  • [26] COMBINED ENERGY DISPERSIVE EXAFS AND X-RAY-DIFFRACTION
    DENT, AJ
    WELLS, MP
    FARROW, RC
    RAMSDALE, CA
    DERBYSHIRE, GE
    GREAVES, GN
    COUVES, JW
    THOMAS, JM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 903 - 906
  • [27] On the method of calibration of the energy dispersive EXAFS beamline at Indus-2 and fitting theoretical model to the EXAFS spectrum
    Gaur, Abhijeet
    Johari, Ajita
    Shrivastava, B. D.
    Gaur, D. C.
    Jha, S. N.
    Bhattacharyya, D.
    Poswal, A.
    Deb, S. K.
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2011, 36 (03): : 339 - 348
  • [28] HOW TO DO EXAFS IN YOUR OWN LABORATORY
    ROBINSON, AL
    SCIENCE, 1979, 205 (4413) : 1367 - 1367
  • [29] On the method of calibration of the energy dispersive EXAFS beamline at Indus-2 and fitting theoretical model to the EXAFS spectrum
    ABHIJEET GAUR
    AJITA JOHARI
    B D SHRIVASTAVA
    D C GAUR
    S N JHA
    D BHATTACHARYYA
    A POSWAL
    S K DEB
    Sadhana, 2011, 36 : 339 - 348
  • [30] ION CHAMBERS FOR FLUORESCENCE AND LABORATORY EXAFS DETECTION
    STERN, EA
    ELAM, WT
    BUNKER, BA
    LU, K
    HEALD, SM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (1-2): : 345 - 346