A new free-hand pedicle screw placement technique with reference to the supraspinal ligament

被引:0
|
作者
Li, Juming [1 ]
Zhao, Hong [1 ]
Xie, Hao [1 ]
Yu, Lipeng [1 ]
Wei, Jifu [1 ]
Zong, Min [2 ]
Chen, Feng [3 ]
Zhu, Ziqiang [1 ]
Zhang, Ning [1 ]
Cao, Xiaojian [1 ]
机构
[1] Nanjing Med Univ, Affiliated Hosp 1, Dept Orthopaed, 300 Guangzhou Rd, Nanjing 210029, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 1, Dept Radiol, Nanjing 210029, Jiangsu, Peoples R China
[3] Nanjing Med Univ, Dept Stat, Nanjing 210029, Jiangsu, Peoples R China
来源
JOURNAL OF BIOMEDICAL RESEARCH | 2014年 / 28卷 / 01期
关键词
spine fracture; pedicle screw placement; radiation exposure; supraspinal ligament; anatomy reference;
D O I
10.7555/JBR.27.20130051
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We sought to compare the safety and accuracy of a new free-hand pedicle screw placement technique to that of the conventional technique. One hundred fifty-three consecutive adult patients with simple fracture in the thoracic or/and lumbar spine were alternately assigned to either the new free-hand or the conventional group. In the new free-hand technique group, preoperative computerized tomography (CT) images were used to calculate the targeted medial-lateral angle of each pedicle trajectory and the pedicle screw was inserted perpendicular to the corresponding supraspinal ligament. In the conventional technique group, the medial-lateral and cranial-caudal angle of each pedicle trajectory was determined by intraoperatively under fluoroscopic guidance. The accuracy rate of pedicle screw placement, the time of intraoperative fluoroscopy, the operating time and the amount of blood loss during operation were respectively compared. All screws were analyzed by using intraoperative radiographs, intraoperative triggered electromyography (EMG) monitoring data, postoperative CT data and clinical outcomes. The accuracy rate of pedicle screw placement in the new free-hand technique group and the conventional technique group was 96.3% and 94.2% (P < 0.05), respectively. The intraoperative fluoroscopy time of the new technique group was less than that of the conventional technique group (5.37 seconds vs. 8.79 seconds, P < 0.05). However, there was no statistical difference in the operating time and the amount of blood loss during operation (P > 0.05). Pedicle screw placement with the free-hand technique which keeps the screw perpendicular to the supraspinal ligament is an accurate, reliable and safe technique to treat simple fracture in the thoracic or lumbar spine.
引用
收藏
页码:64 / 70
页数:7
相关论文
共 50 条
  • [31] Accuracy and safety of free-hand pedicle screw fixation in age less than 10 years
    Hyoung Yeon Seo
    Ji Hyeon Yim
    Jung Pil Heo
    Abhishek S. Patil
    Seung Min Na
    Sung Kyu Kim
    Jae Yoon Chung
    Indian Journal of Orthopaedics, 2013, 47 : 559 - 564
  • [32] A five-step remedial screw placement method to treat severe spinal deformity with free-hand transpedicular screw placement
    Jing-Ming Xie
    Zhi Zhao
    Hua Yang
    Ying-Song Wang
    Ying Zhang
    Tao Li
    Ni Bi
    European Spine Journal, 2013, 22 : 417 - 424
  • [33] Free hand pedicle screw placement in the thoracic spine: Is it safe? Point of view
    Kabins, MB
    SPINE, 2004, 29 (03) : 342 - 342
  • [34] A five-step remedial screw placement method to treat severe spinal deformity with free-hand transpedicular screw placement
    Xie, Jing-Ming
    Zhao, Zhi
    Yang, Hua
    Wang, Ying-Song
    Zhang, Ying
    Li, Tao
    Bi, Ni
    EUROPEAN SPINE JOURNAL, 2013, 22 (02) : 417 - 424
  • [35] Evaluation of free-hand screw placement in cervical, thoracic, and lumbar spine by neurosurgical residents
    Casillo, Stephanie M.
    Agarwal, Prateek
    Nwachuku, Enyinna L.
    Agarwal, Nitin
    Miele, Vincent J.
    Hamilton, David K.
    Alan, Nima
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 204
  • [36] Morphologic evaluation of the thoracic vertebrae for safe free-hand pedicle screw placement in adolescent idiopathic scoliosis: a CT-based anatomical study
    Cui, Guanyu
    Watanabe, Kota
    Hosogane, Naobumi
    Tsuji, Takashi
    Ishii, Ken
    Nakamura, Masaya
    Toyama, Yoshiaki
    Chiba, Kazuhiro
    Lenke, Lawrence G.
    Matsumoto, Morio
    SURGICAL AND RADIOLOGIC ANATOMY, 2012, 34 (03) : 209 - 216
  • [37] CENTRAL BREAST PEDICLE AND FREE-HAND TECHNIQUE FOR ALTERATION OF VOLUME AND SKIN ENVELOPE OF THE BREAST
    HESTER, TR
    CUKIC, J
    CLINICS IN PLASTIC SURGERY, 1988, 15 (04) : 613 - 625
  • [38] Morphologic evaluation of the thoracic vertebrae for safe free-hand pedicle screw placement in adolescent idiopathic scoliosis: a CT-based anatomical study
    Guanyu Cui
    Kota Watanabe
    Naobumi Hosogane
    Takashi Tsuji
    Ken Ishii
    Masaya Nakamura
    Yoshiaki Toyama
    Kazuhiro Chiba
    Lawrence G. Lenke
    Morio Matsumoto
    Surgical and Radiologic Anatomy, 2012, 34 : 209 - 216
  • [39] Modified Mini-open Transforaminal Lumbar Interbody Fusion: Description of Surgical Technique and Assessment of Free-hand Pedicle Screw Insertion
    Pakzaban, Peyman
    SPINE, 2016, 41 (18) : E1124 - E1130
  • [40] Novel free-hand T1 pedicle screw method: Review of 44 consecutive cases
    Rivkin, Mark A.
    Okun, Jessica F.
    Yocom, Steven S.
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2014, 5 (04) : 349 - 354