A new free-hand pedicle screw placement technique with reference to the supraspinal ligament

被引:0
|
作者
Li, Juming [1 ]
Zhao, Hong [1 ]
Xie, Hao [1 ]
Yu, Lipeng [1 ]
Wei, Jifu [1 ]
Zong, Min [2 ]
Chen, Feng [3 ]
Zhu, Ziqiang [1 ]
Zhang, Ning [1 ]
Cao, Xiaojian [1 ]
机构
[1] Nanjing Med Univ, Affiliated Hosp 1, Dept Orthopaed, 300 Guangzhou Rd, Nanjing 210029, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 1, Dept Radiol, Nanjing 210029, Jiangsu, Peoples R China
[3] Nanjing Med Univ, Dept Stat, Nanjing 210029, Jiangsu, Peoples R China
来源
JOURNAL OF BIOMEDICAL RESEARCH | 2014年 / 28卷 / 01期
关键词
spine fracture; pedicle screw placement; radiation exposure; supraspinal ligament; anatomy reference;
D O I
10.7555/JBR.27.20130051
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We sought to compare the safety and accuracy of a new free-hand pedicle screw placement technique to that of the conventional technique. One hundred fifty-three consecutive adult patients with simple fracture in the thoracic or/and lumbar spine were alternately assigned to either the new free-hand or the conventional group. In the new free-hand technique group, preoperative computerized tomography (CT) images were used to calculate the targeted medial-lateral angle of each pedicle trajectory and the pedicle screw was inserted perpendicular to the corresponding supraspinal ligament. In the conventional technique group, the medial-lateral and cranial-caudal angle of each pedicle trajectory was determined by intraoperatively under fluoroscopic guidance. The accuracy rate of pedicle screw placement, the time of intraoperative fluoroscopy, the operating time and the amount of blood loss during operation were respectively compared. All screws were analyzed by using intraoperative radiographs, intraoperative triggered electromyography (EMG) monitoring data, postoperative CT data and clinical outcomes. The accuracy rate of pedicle screw placement in the new free-hand technique group and the conventional technique group was 96.3% and 94.2% (P < 0.05), respectively. The intraoperative fluoroscopy time of the new technique group was less than that of the conventional technique group (5.37 seconds vs. 8.79 seconds, P < 0.05). However, there was no statistical difference in the operating time and the amount of blood loss during operation (P > 0.05). Pedicle screw placement with the free-hand technique which keeps the screw perpendicular to the supraspinal ligament is an accurate, reliable and safe technique to treat simple fracture in the thoracic or lumbar spine.
引用
收藏
页码:64 / 70
页数:7
相关论文
共 50 条
  • [21] Free hand pedicle screw placement in the thoracic spine: Is it safe?
    Kim, YJ
    Lenke, LG
    Bridwell, KH
    Cho, YSS
    Riew, KD
    SPINE, 2004, 29 (03) : 333 - 342
  • [22] Free-Hand Pedicle Screw Insertion of Thoracic Spine Using Fennell Technique: Initial Results and Review of Literature
    Satapathy, Ayusman
    Dash, Chinmaya
    Sharma, Arunav
    Sahu, Rabi Narayan
    INDIAN JOURNAL OF NEUROTRAUMA, 2019, 16 (01): : 10 - 13
  • [23] Accuracy of thoracic pedicle screw placement in adolescent patients with severe spinal deformities: a retrospective study comparing drill guide template with free-hand technique
    Pan, Yue
    Lu, G. H.
    Kuang, Lei
    Wang, Bing
    EUROPEAN SPINE JOURNAL, 2018, 27 (02) : 319 - 326
  • [24] Accuracy of thoracic pedicle screw placement in adolescent patients with severe spinal deformities: a retrospective study comparing drill guide template with free-hand technique
    Yue Pan
    G. H. Lü
    Lei Kuang
    Bing Wang
    European Spine Journal, 2018, 27 : 319 - 326
  • [25] Comparison of accuracy and safety between second-generation TiRobot-assisted and free-hand thoracolumbar pedicle screw placement
    Yan, Kai
    Zhang, Qi
    Tian, Wei
    BMC SURGERY, 2022, 22 (01)
  • [26] Free-Hand Cervical Pedicle Screw Placement by Using Para-articular Minilaminotomy: Its Feasibility and Novice Neurosurgeons' Experience
    Park, Jong-Hwa
    Lee, Jong Young
    Lee, Byoung Hun
    Jeon, Hong Jun
    Park, Seung-Woo
    GLOBAL SPINE JOURNAL, 2021, 11 (05) : 662 - 668
  • [27] Feasibility Study of Free-Hand Technique for Pedicle Screw Insertion at C7 without Fluoroscopy-Guidance
    Lee, Gun Woo
    Kim, Ho-Joong
    Yeom, Jin S.
    Uh, Jae-Hyung
    Park, Jong-Ho
    Lee, Ji-Hoon
    Kim, Dong-Wook
    Suh, Bo-Gun
    ASIAN SPINE JOURNAL, 2016, 10 (01) : 38 - 45
  • [28] Comparison of accuracy and safety between second-generation TiRobot-assisted and free-hand thoracolumbar pedicle screw placement
    Kai Yan
    Qi Zhang
    Wei Tian
    BMC Surgery, 22
  • [29] Lumbar and sacral pedicle screw placement using a template does not improve the midterm pain and disability outcome in comparison with free-hand method
    Merc M.
    Recnik G.
    Krajnc Z.
    European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (5) : 583 - 589
  • [30] Accuracy and safety of free-hand pedicle screw fixation in age less than 10 years
    Seo, Hyoung Yeon
    Yim, Ji Hyeon
    Heo, Jung Pil
    Patil, Abhishek S.
    Na, Seung Min
    Kim, Sung Kyu
    Chung, Jae Yoon
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (06) : 559 - 564