Effects of Eccentric Impeller Position on Radial Passive Stability in a Magnetically Levitated Centrifugal Blood Pump with a Double Volute

被引:9
|
作者
Shida, Shuya [1 ,3 ]
Masuzawa, Toru [2 ]
Osa, Masahiro [2 ]
Sato, Ryota [1 ]
机构
[1] Ibaraki Univ, Grad Sch Sci & Engn, Hitachi, Ibaraki, Japan
[2] Ibaraki Univ, Dept Mech Engn, Hitachi, Ibaraki, Japan
[3] 4-12-1 Nakanarusawa, Hitachi, Ibaraki 3168511, Japan
关键词
eccentric impeller position; double volute; magnetic suspension; hydraulic force; computational fluid dynamics (CFD);
D O I
10.14326/abe.7.63
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Evaluation of the impeller radial stability is important from the bioengineering point of view in the development of mechanical circulatory support devices (MCSDs) for safer use as bridge for several months or destination therapy for years. In this study, radial stability of a magnetically levitated impeller in a centrifugal blood pump with an axially magnetic suspension system was evaluated by investigating the effects of the eccentric impeller position on passive stability, aiming to propose a pump design guide for the development and safer clinical use of MCSDs. First, impeller displacements in the prototype pump were measured using a mock loop together with laser displacement sensors. Then, the radial hydraulic forces exerted on an eccentric impeller were calculated using computational fluid dynamics (CFD) analysis for four volute-casing geometries. In addition, hemocompatibility was assessed using CFD calculations of scalar shear stress exerted on blood. Measurement of impeller displacement showed that the displacement varied from 0.56 to 0.27 mm at a rotational speed of 1800 rpm as the flow rate increased from 0 to 6.5 L/min. In the CFD calculation, the radial hydraulic force increased linearly from 0.2 to 1.7 N as the impeller displacement increased from 0 to 0.5 mm for all the double volute geometries, under conditions of a rotational speed of 1800 rpm and flow rates of 3, 5 and 7 L/min. These results indicate that the impeller stability in the prototype pump is acceptable at the operation conditions of ventricular assist devices, because the magnetic bearing stiffness of radial component was 4.1 N/mm. In the pressure recovery analysis of eccentric impellers, a double volute was not effective because of the unbalanced pressure field generated by the unbalanced pressure recovery. Thus, the increase in radial hydraulic force associated with an eccentric impeller could not be avoided by changing the conventional double volute design. The CFD analysis of geometrical variation indicated that widening of the radial clearance is an effective approach to improve the radial stability as well as hemocompatibility, although the radial clearance should be designed based on trade-offs among impeller stability, hemocompatibility and pump performance.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 50 条
  • [31] Magnetically suspended centrifugal blood pump with a radial magnetic driver
    Hoshi, H
    Katakoa, K
    Ohuchi, K
    Asama, J
    Shinshi, T
    Shimokohbe, A
    Takatani, S
    ASAIO JOURNAL, 2005, 51 (01) : 60 - 64
  • [32] Mitigation of pressure fluctuation through an impeller with splitter blades for a double-volute centrifugal pump
    Kang, Can
    Teng, Shuang
    Hu, Jiang
    Ding, Kejin
    Zhang, Wenbin
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2023, 46 (03) : 293 - 303
  • [33] Effects of the number of blades on impeller-volute interaction and flow instability of a centrifugal pump
    Shim, Hyeon-Seok
    Kim, Kwang-Yong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2022, 236 (08) : 1500 - 1517
  • [34] Numerical simulation of the dynamic effects due to impeller-volute interaction in a centrifugal pump
    González, J
    Fernández, J
    Blanco, E
    Santolaria, C
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (02): : 348 - 355
  • [36] Experimental study on the whirling motion in the centrifugal blood pump with a magnetically coupled impeller
    Tsukiya, Tomonori
    Taenaka, Yoshiyuki
    Suzuki, Takayuki
    Horiguchi, Hironori
    Tsujimoto, Yoshinobu
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2008, 74 (07): : 1557 - 1563
  • [37] Dynamic Stability Analysis of Magnetically Levitated Rotor in a Nutation Blood Pump
    Chen, Gang
    Wang, Kun-Chieh
    SENSORS AND MATERIALS, 2024, 36 (10) : 4205 - 4220
  • [38] EFFECTS OF BLADE NUMBER ON HYDRAULIC FORCE PERTURBATION ON IMPELLER OF VOLUTE-TYPE CENTRIFUGAL PUMP
    HASEGAWA, Y
    KIKUYAMA, K
    MAEDA, T
    JSME INTERNATIONAL JOURNAL SERIES II-FLUIDS ENGINEERING HEAT TRANSFER POWER COMBUSTION THERMOPHYSICAL PROPERTIES, 1990, 33 (04): : 736 - 742
  • [39] An ultradurable and compact rotary blood pump with a magnetically suspended impeller in the radial direction
    Masuzawa, T
    Kita, T
    Okada, Y
    ARTIFICIAL ORGANS, 2001, 25 (05) : 395 - 399
  • [40] Centrifugal blood pump with a hydraulically-levitated impeller for a permanently implantable biventricular assist device
    Watanabe, K
    Ichikawa, S
    Asai, T
    Motomura, T
    Hata, A
    Ito, S
    Shinohara, T
    Tsujimura, S
    Glueck, JA
    Oestmann, DJ
    Nosé, Y
    ARTIFICIAL ORGANS, 2004, 28 (06) : 556 - 563