Comparison of Three- and Four-dimensional Robotic Radiotherapy Treatment Plans for Lung Cancers

被引:2
|
作者
Chai, Gyu Young [1 ]
Lim, Young Kyung [1 ]
Kang, Ki Mun [1 ]
Jeong, Bae Gwon [1 ]
Ha, In-Bong [1 ]
Park, Kyung Bum [2 ]
Jung, Jin-Myung [2 ]
Kim, Dongwook [3 ]
机构
[1] Gyeongsang Natl Univ Hosp, Dept Radiat Oncol, Jinju, South Korea
[2] Gyeongsang Natl Univ Hosp, Dept Neurosurg, Jinju, South Korea
[3] Kyung Hee Univ, Dept Radiat Oncol, Int Med Serv, Seoul, South Korea
来源
RADIATION ONCOLOGY JOURNAL | 2010年 / 28卷 / 04期
关键词
Lung cancer; Robotic radiotherapy; Four-dimensional radiation treatment plan; Monte Carlo algorithm;
D O I
10.3857/jkstro.2010.28.4.238
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare the dose distributions between three-dimensional (3D) and four-dimensional (4D) radiation treatment plans calculated by Ray-tracing or the Monte Carlo algorithm, and to highlight the difference of dose calculation between two algorithms for lung heterogeneity correction in lung cancers. Materials and Methods: Prospectively gated 4D CTs in seven patients were obtained with a Brilliance CT64-Channel scanner along with a respiratory bellows gating device. After 4D treatment planning with the Ray Tracing algorithm in Multiplan 3.5.1, a CyberKnife stereotactic radiotherapy planning system, 3D Ray Tracing, 3D and 4D Monte Carlo dose calculations were performed under the same beam conditions (same number, directions, monitor units of beams). The 3D plan was performed in a primary CT image setting corresponding to middle phase expiration (50%). Relative dose coverage, D95 of gross tumor volume and planning target volume, maximum doses of tumor, and the spinal cord were compared for each plan, taking into consideration the tumor location. Results: According to the Monte Carlo calculations, mean tumor volume coverage of the 4D plans was 4.4% higher than the 3D plans when tumors were located in the lower lobes of the lung, but were 4.6% lower when tumors were located in the upper lobes of the lung. Similarly, the D95 of 4D plans was 4.8% higher than 3D plans when tumors were located in the lower lobes of lung, but was 1.7% lower when tumors were located in the upper lobes of lung. This tendency was also observed at the maximum dose of the spinal cord. Lastly, a 30% reduction in the PTV volume coverage was observed for the Monte Carlo calculation compared with the Ray-tracing calculation. Conclusion: 3D and 4D robotic radiotherapy treatment plans for lung cancers were compared according to a dosimetric viewpoint for a tumor and the spinal cord. The difference of tumor dose distributions between 3D and 4D treatment plans was only significant when large tumor movement and deformation was suspected. Therefore, 4D treatment planning is only necessary for large tumor motion and deformation. However, a Monte Carlo calculation is always necessary, independent of tumor motion in the lung.
引用
收藏
页码:238 / 248
页数:11
相关论文
共 50 条
  • [31] Three- and four-dimensional visualization of cell migration using optical coherence tomography
    Rey, Sara M.
    Povazay, Boris
    Hofer, Bernd
    Unterhuber, Angelika
    Hermann, Boris
    Harwood, Adrian
    Drexler, Wolfgang
    JOURNAL OF BIOPHOTONICS, 2009, 2 (6-7) : 370 - 379
  • [32] A counting problem on lattice points in two-, three- and four-dimensional spaces
    Duan, Lingjie
    Xu, Zongwei
    Liu, Yongchang
    Duan, Junsheng
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2022, 34 (04)
  • [33] Three- and four-dimensional ultrasound in fetal echocardiography: an up-to-date overview
    Adriaanse, B. M. E.
    van Vugt, J. M. G.
    Haak, M. C.
    JOURNAL OF PERINATOLOGY, 2016, 36 (09) : 685 - 693
  • [34] New developments in fetal heart scanning: Three- and four-dimensional fetal echocardiography
    Chaoui, R
    Heling, KS
    SEMINARS IN FETAL & NEONATAL MEDICINE, 2005, 10 (06): : 567 - 577
  • [35] Three- and four-dimensional arterial and venous anatomies of the thoracodorsal artery perforator flap
    Schaverien, Mark
    Saint-Cyr, Michel
    Arbique, Gary
    Brown, Spencer A.
    Rohrich, Rod J.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 121 (05) : 1578 - 1587
  • [36] The homotopy classification of three- and four-dimensional analogs of the Cauchy-Riemann system
    Uss, AT
    DIFFERENTIAL EQUATIONS, 2004, 40 (08) : 1184 - 1191
  • [37] Three- and four-dimensional ultrasound in fetal echocardiography: an up-to-date overview
    B M E Adriaanse
    J M G van Vugt
    M C Haak
    Journal of Perinatology, 2016, 36 : 685 - 693
  • [38] New scoring system for fetal neurobehavior assessed by three- and four-dimensional sonography
    Kurjak, Asim
    Miskovic, Berivoj
    Stanoievic, Milan
    Amiel-Tison, Claudine
    Ahmed, Badreldeen
    Azumendi, Guillermo
    Vasilj, Oliver
    Andonotopo, Wiku
    Turudic, Tanja
    Salihagic-Kadic, Aida
    JOURNAL OF PERINATAL MEDICINE, 2008, 36 (01) : 73 - 81
  • [39] Three- and four-dimensional ultrasound: new methods for evaluating fetal thoracic anomalies
    Achiron, R.
    Gindes, L.
    Zalel, Y.
    Lipitz, S.
    Weisz, B.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 32 (01) : 36 - 43