Comparison of Three- and Four-dimensional Robotic Radiotherapy Treatment Plans for Lung Cancers

被引:2
|
作者
Chai, Gyu Young [1 ]
Lim, Young Kyung [1 ]
Kang, Ki Mun [1 ]
Jeong, Bae Gwon [1 ]
Ha, In-Bong [1 ]
Park, Kyung Bum [2 ]
Jung, Jin-Myung [2 ]
Kim, Dongwook [3 ]
机构
[1] Gyeongsang Natl Univ Hosp, Dept Radiat Oncol, Jinju, South Korea
[2] Gyeongsang Natl Univ Hosp, Dept Neurosurg, Jinju, South Korea
[3] Kyung Hee Univ, Dept Radiat Oncol, Int Med Serv, Seoul, South Korea
来源
RADIATION ONCOLOGY JOURNAL | 2010年 / 28卷 / 04期
关键词
Lung cancer; Robotic radiotherapy; Four-dimensional radiation treatment plan; Monte Carlo algorithm;
D O I
10.3857/jkstro.2010.28.4.238
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare the dose distributions between three-dimensional (3D) and four-dimensional (4D) radiation treatment plans calculated by Ray-tracing or the Monte Carlo algorithm, and to highlight the difference of dose calculation between two algorithms for lung heterogeneity correction in lung cancers. Materials and Methods: Prospectively gated 4D CTs in seven patients were obtained with a Brilliance CT64-Channel scanner along with a respiratory bellows gating device. After 4D treatment planning with the Ray Tracing algorithm in Multiplan 3.5.1, a CyberKnife stereotactic radiotherapy planning system, 3D Ray Tracing, 3D and 4D Monte Carlo dose calculations were performed under the same beam conditions (same number, directions, monitor units of beams). The 3D plan was performed in a primary CT image setting corresponding to middle phase expiration (50%). Relative dose coverage, D95 of gross tumor volume and planning target volume, maximum doses of tumor, and the spinal cord were compared for each plan, taking into consideration the tumor location. Results: According to the Monte Carlo calculations, mean tumor volume coverage of the 4D plans was 4.4% higher than the 3D plans when tumors were located in the lower lobes of the lung, but were 4.6% lower when tumors were located in the upper lobes of the lung. Similarly, the D95 of 4D plans was 4.8% higher than 3D plans when tumors were located in the lower lobes of lung, but was 1.7% lower when tumors were located in the upper lobes of lung. This tendency was also observed at the maximum dose of the spinal cord. Lastly, a 30% reduction in the PTV volume coverage was observed for the Monte Carlo calculation compared with the Ray-tracing calculation. Conclusion: 3D and 4D robotic radiotherapy treatment plans for lung cancers were compared according to a dosimetric viewpoint for a tumor and the spinal cord. The difference of tumor dose distributions between 3D and 4D treatment plans was only significant when large tumor movement and deformation was suspected. Therefore, 4D treatment planning is only necessary for large tumor motion and deformation. However, a Monte Carlo calculation is always necessary, independent of tumor motion in the lung.
引用
收藏
页码:238 / 248
页数:11
相关论文
共 50 条
  • [21] On absolute continuity of the spectrum of three- and four-dimensional periodic Schrodinger operators
    Danilov, L. I.
    JOURNAL OF PHYSICS A-MATHEMATICAL AND THEORETICAL, 2010, 43 (21)
  • [22] On the time-optimal problem for three- and four-dimensional control systems
    Nikol'skii, M. S.
    PROCEEDINGS OF THE STEKLOV INSTITUTE OF MATHEMATICS, 2012, 277 (01) : 184 - 190
  • [23] Palatalization in coronal consonants of Polish: A three-/four-dimensional ultrasound study
    Cavar, Malgorzata E.
    Rudman, Emily M.
    Lulich, Steven M.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2020, 148 (06): : EL447 - EL452
  • [24] Diagnosis of fetal syndromes by three- and four-dimensional ultrasound: is there any improvement?
    Barisic, Lara Spalldi
    Stanojevic, Milan
    Kurjak, Asim
    Porovic, Selma
    Gaber, Ghalia
    JOURNAL OF PERINATAL MEDICINE, 2017, 45 (06) : 651 - 665
  • [25] Relations in Grassmann Algebra Corresponding to Three- and Four-Dimensional Pachner Moves
    Korepanov, Igor G.
    SYMMETRY INTEGRABILITY AND GEOMETRY-METHODS AND APPLICATIONS, 2011, 7
  • [26] On the time-optimal problem for three- and four-dimensional control systems
    M. S. Nikol’skii
    Proceedings of the Steklov Institute of Mathematics, 2012, 277 : 184 - 190
  • [27] A novel four-dimensional radiotherapy method for lung cancer: imaging, treatment planning and delivery
    Alasti, H.
    Cho, Y. B.
    Vandermeer, A. D.
    Abbas, A.
    Norrlinger, B.
    Shubbar, S.
    Bezjak, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (12): : 3251 - 3267
  • [28] Four-dimensional treatment planning for stereotactic body radiotherapy
    Guckenberger, Matthias
    Wilbert, Juergen
    Krieger, Thomas
    Richter, Anne
    Baier, Kurt
    Meyer, Juergen
    Flentje, Michael
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01): : 276 - 285
  • [29] Four-dimensional radiotherapy planning
    Keall, P
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S140 - S140
  • [30] Dioptric power: Its nature and its representation in three- and four-dimensional space
    Harris, WF
    OPTOMETRY AND VISION SCIENCE, 1997, 74 (06) : 349 - 366