Comparison of Three- and Four-dimensional Robotic Radiotherapy Treatment Plans for Lung Cancers

被引:2
|
作者
Chai, Gyu Young [1 ]
Lim, Young Kyung [1 ]
Kang, Ki Mun [1 ]
Jeong, Bae Gwon [1 ]
Ha, In-Bong [1 ]
Park, Kyung Bum [2 ]
Jung, Jin-Myung [2 ]
Kim, Dongwook [3 ]
机构
[1] Gyeongsang Natl Univ Hosp, Dept Radiat Oncol, Jinju, South Korea
[2] Gyeongsang Natl Univ Hosp, Dept Neurosurg, Jinju, South Korea
[3] Kyung Hee Univ, Dept Radiat Oncol, Int Med Serv, Seoul, South Korea
来源
RADIATION ONCOLOGY JOURNAL | 2010年 / 28卷 / 04期
关键词
Lung cancer; Robotic radiotherapy; Four-dimensional radiation treatment plan; Monte Carlo algorithm;
D O I
10.3857/jkstro.2010.28.4.238
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare the dose distributions between three-dimensional (3D) and four-dimensional (4D) radiation treatment plans calculated by Ray-tracing or the Monte Carlo algorithm, and to highlight the difference of dose calculation between two algorithms for lung heterogeneity correction in lung cancers. Materials and Methods: Prospectively gated 4D CTs in seven patients were obtained with a Brilliance CT64-Channel scanner along with a respiratory bellows gating device. After 4D treatment planning with the Ray Tracing algorithm in Multiplan 3.5.1, a CyberKnife stereotactic radiotherapy planning system, 3D Ray Tracing, 3D and 4D Monte Carlo dose calculations were performed under the same beam conditions (same number, directions, monitor units of beams). The 3D plan was performed in a primary CT image setting corresponding to middle phase expiration (50%). Relative dose coverage, D95 of gross tumor volume and planning target volume, maximum doses of tumor, and the spinal cord were compared for each plan, taking into consideration the tumor location. Results: According to the Monte Carlo calculations, mean tumor volume coverage of the 4D plans was 4.4% higher than the 3D plans when tumors were located in the lower lobes of the lung, but were 4.6% lower when tumors were located in the upper lobes of the lung. Similarly, the D95 of 4D plans was 4.8% higher than 3D plans when tumors were located in the lower lobes of lung, but was 1.7% lower when tumors were located in the upper lobes of lung. This tendency was also observed at the maximum dose of the spinal cord. Lastly, a 30% reduction in the PTV volume coverage was observed for the Monte Carlo calculation compared with the Ray-tracing calculation. Conclusion: 3D and 4D robotic radiotherapy treatment plans for lung cancers were compared according to a dosimetric viewpoint for a tumor and the spinal cord. The difference of tumor dose distributions between 3D and 4D treatment plans was only significant when large tumor movement and deformation was suspected. Therefore, 4D treatment planning is only necessary for large tumor motion and deformation. However, a Monte Carlo calculation is always necessary, independent of tumor motion in the lung.
引用
收藏
页码:238 / 248
页数:11
相关论文
共 50 条
  • [1] Comparison of Dose Coverage of Lung Tumor Volume in Three- and Four-Dimensional Robotic Radiotherapy Treatment Planning
    Lim, Young Kyung
    JOURNAL OF THORACIC ONCOLOGY, 2010, 5 (12) : S415 - S415
  • [2] Comparison of Radiotherapy Treatment Plans for Left-sided Breast Cancer Patients based on Three- and Four-dimensional Computed Tomography Imaging
    Bedi, C.
    Kron, T.
    Willis, D.
    Hubbard, P.
    Milner, A.
    Chua, B.
    CLINICAL ONCOLOGY, 2011, 23 (09) : 601 - 607
  • [3] Dosimetric comparison between three- and four-dimensional computerised tomography radiotherapy for breast cancer
    Yan, Yanli
    Lu, Zhou
    Liu, Zi
    Luo, Wei
    Shao, Shuai
    Tan, Li
    Ma, Xiaowei
    Liu, Jiaxin
    Drokow, Emmanuel Kwateng
    Ren, Juan
    ONCOLOGY LETTERS, 2019, 18 (02) : 1800 - 1814
  • [4] Three- and Four-Dimensional Fetal Echocardiography
    Turan, Sifa
    Turan, Ozhan
    Baschat, Ahmet A.
    FETAL DIAGNOSIS AND THERAPY, 2009, 25 (04) : 361 - 372
  • [5] Advancing orthodontic treatment planning - three- and four-dimensional imaging
    Quast, Anja
    Mouchoux, Jeremy
    Wiechens, Bernhard
    Meyer-Marcotty, Philipp
    INFORMATIONEN AUS ORTHODONTIE UND KIEFERORTHOPAEDIE, 2025, 57 (01): : 9 - 17
  • [6] Perception of rigidity in three- and four-dimensional spaces
    He, Dongcheng
    Nguyen, Dat-Thanh
    Ogmen, Haluk
    Nishina, Shigeaki
    Yazdanbakhsh, Arash
    FRONTIERS IN PSYCHOLOGY, 2023, 14
  • [7] Three- and Four-Dimensional Topographic Measurement and Validation
    Rocca, Fabio
    Li, Deren
    Tebaldini, Stefano
    Liao, Mingsheng
    Zhang, Lu
    Lombardini, Fabrizio
    Balz, Timo
    Haala, Norbert
    Ding, Xiaoli
    Hanssen, Ramon
    REMOTE SENSING, 2021, 13 (15)
  • [8] Homoclinic orbits and chaos in three- and four-dimensional flows
    Holmes, P
    Doelman, A
    Hek, G
    Domokos, G
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2001, 359 (1784): : 1429 - 1438
  • [9] Critical properties of the three- and four-dimensional gauge glass
    Katzgraber, HG
    Campbell, IA
    PHYSICAL REVIEW B, 2004, 69 (09)
  • [10] On the correspondence between the three- and four-dimensional parameters of the three-dimensional rotation group
    S. E. Perelyaev
    Mechanics of Solids, 2009, 44 : 204 - 213