COMPARISON OF HYDROPHOBIC HEAT AND MOISTURE EXCHANGERS WITH HEATED HUMIDIFIER DURING PROLONGED MECHANICAL VENTILATION

被引:105
|
作者
ROUSTAN, JP [1 ]
KIENLEN, J [1 ]
AUBAS, P [1 ]
AUBAS, S [1 ]
DUCAILAR, J [1 ]
机构
[1] HOP LAPEYRONIE, DEPT INFORMAT MED, F-34059 MONTPELLIER, FRANCE
关键词
EQUIPMENT; MECHANICAL VENTILATION; HEAT AND BACTERIAL FILTER;
D O I
10.1007/BF01705040
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Inspired gases must be warmed and humidified during mechanical ventilation. In a prospective randomized study we compared the performance of a heated humidifier (HH) (Draegger Aquaport) and a heat and moisture exchanger (HME) (Pall Filter BB 2215). A total of 116 patients requiring mechanical ventilation (Servo 900 C Siemens) were enrolled into the study and were randomly assigned to 2 groups. Patients in group I were ventilated with a traditional breathing circuit with HH and patients in group II using a simplified circuit with HME. Pre-existing and hospital acquired atelectasis and pneumonia, occurrence of endotracheal tube (ET) occlusion and ventilatory parameters (respiratory rate, tidal volume) were studied. No statistical difference was found between groups for each parameter except the greater frequency of ET occlusions in the II group (0/61 vs 9/55) (P = 0.0008). Pall Filter (PF), a hydrophobic filter, humidifies the dry gases from the condensed water which is put down on the HME surfaces during cooling of saturated expired gases. This purely physical property is linked to the magnitude of the thermic gradient between the expired gases and the ambient temperature. Performance impairment of PF in our study might be due to high ambient temperature in the intensive care unit (usually around 28-degrees-C) which reduces thermic gradient and water exchanges. We conclude that efficiency of PF may be weak in some conditions of ambient temperature.
引用
收藏
页码:97 / 100
页数:4
相关论文
共 50 条
  • [41] MAINTENANCE OF BODY-TEMPERATURE IN ELDERLY PATIENTS WHO HAVE JOINT REPLACEMENT SURGERY - A COMPARISON BETWEEN THE HEAT AND MOISTURE EXCHANGER AND HEATED HUMIDIFIER
    YAM, PCI
    CARLI, F
    ANAESTHESIA, 1990, 45 (07) : 563 - 565
  • [42] Placement of the nebulizer before the humidifier during mechanical ventilation: Effect on aerosol delivery
    Moraine, Jean-Jacques
    Truflandier, Karine
    Vandenbergen, Nicolas
    Berre, Jacques
    Melot, Christian
    Vincent, Jean-Louis
    HEART & LUNG, 2009, 38 (05): : 435 - 439
  • [43] Evaluation of the efficiency of heat and moisture exchangers during paediatric anaesthesia
    Luchetti, M
    Pigna, A
    Gentili, A
    Marraro, G
    PAEDIATRIC ANAESTHESIA, 1999, 9 (01): : 39 - 45
  • [44] THE WORK OF BREATHING IMPOSED BY HEAT AND MOISTURE EXCHANGERS DURING WEANING
    OOI, R
    BROWNE, G
    SONI, N
    ANESTHESIOLOGY, 1993, 79 (3A) : A295 - A295
  • [45] Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure
    Pelosi, P
    Solca, M
    Ravagnan, I
    Tubiolo, D
    Ferrario, L
    Gattinoni, L
    CRITICAL CARE MEDICINE, 1996, 24 (07) : 1184 - 1188
  • [46] Prolonged use of heat and moisture exchangers: Why do we keep changing things?
    Hess, D
    CRITICAL CARE MEDICINE, 2000, 28 (05) : 1667 - 1668
  • [47] Piglet diaphragm function during prolonged mechanical ventilation
    Radell, PJ
    Remahl, S
    Nichols, DG
    Eriksson, LI
    ANESTHESIOLOGY, 2000, 93 (3A) : U233 - U233
  • [48] An efficiency comparison of four heat and moisture exchangers used in the laryngectomized patient
    Grolman, W
    Blom, ED
    Branson, RD
    Schouwenburg, PF
    Hamaker, RC
    LARYNGOSCOPE, 1997, 107 (06): : 814 - 820
  • [49] Physicians' attitude to use heat and moisture exchangers or heated humidifiers: a Franco-Canadian survey
    Ricard, JD
    Cook, D
    Griffith, L
    Brochard, L
    Dreyfuss, D
    INTENSIVE CARE MEDICINE, 2002, 28 (06) : 719 - 725
  • [50] Physicians' attitude to use heat and moisture exchangers or heated humidifiers: a Franco-Canadian survey
    Jean-Damien Ricard
    Deborah Cook
    Lauren Griffith
    Laurent Brochard
    Didier Dreyfuss
    Intensive Care Medicine, 2002, 28 : 719 - 725