COMPARISON OF HYDROPHOBIC HEAT AND MOISTURE EXCHANGERS WITH HEATED HUMIDIFIER DURING PROLONGED MECHANICAL VENTILATION

被引:105
|
作者
ROUSTAN, JP [1 ]
KIENLEN, J [1 ]
AUBAS, P [1 ]
AUBAS, S [1 ]
DUCAILAR, J [1 ]
机构
[1] HOP LAPEYRONIE, DEPT INFORMAT MED, F-34059 MONTPELLIER, FRANCE
关键词
EQUIPMENT; MECHANICAL VENTILATION; HEAT AND BACTERIAL FILTER;
D O I
10.1007/BF01705040
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Inspired gases must be warmed and humidified during mechanical ventilation. In a prospective randomized study we compared the performance of a heated humidifier (HH) (Draegger Aquaport) and a heat and moisture exchanger (HME) (Pall Filter BB 2215). A total of 116 patients requiring mechanical ventilation (Servo 900 C Siemens) were enrolled into the study and were randomly assigned to 2 groups. Patients in group I were ventilated with a traditional breathing circuit with HH and patients in group II using a simplified circuit with HME. Pre-existing and hospital acquired atelectasis and pneumonia, occurrence of endotracheal tube (ET) occlusion and ventilatory parameters (respiratory rate, tidal volume) were studied. No statistical difference was found between groups for each parameter except the greater frequency of ET occlusions in the II group (0/61 vs 9/55) (P = 0.0008). Pall Filter (PF), a hydrophobic filter, humidifies the dry gases from the condensed water which is put down on the HME surfaces during cooling of saturated expired gases. This purely physical property is linked to the magnitude of the thermic gradient between the expired gases and the ambient temperature. Performance impairment of PF in our study might be due to high ambient temperature in the intensive care unit (usually around 28-degrees-C) which reduces thermic gradient and water exchanges. We conclude that efficiency of PF may be weak in some conditions of ambient temperature.
引用
收藏
页码:97 / 100
页数:4
相关论文
共 50 条
  • [31] Mechanical effects of heat-moisture exchangers in ventilated patients
    Iotti, GA
    Olivei, MC
    Braschi, A
    CRITICAL CARE, 1999, 3 (05): : R77 - R82
  • [32] Unfavorable mechanical effects of heat and moisture exchangers in ventilated patients
    Iotti, GA
    Olivei, MC
    Palo, A
    Galbusera, C
    Veronesi, R
    Comelli, A
    Brunner, JX
    Braschi, A
    INTENSIVE CARE MEDICINE, 1997, 23 (04) : 399 - 405
  • [33] A comparison of the active heat and moisture exchanging filter with a hot water bath humidifier and a standard heat and moisture exchanging filter
    Pulimood, TB
    Webb, P
    Park, GR
    BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (02) : 364P - 364P
  • [34] Noninvasive ventilation during weaning from prolonged mechanical ventilation
    Ceriana, Piero
    Nava, Stefano
    Vitacca, Michele
    Carlucci, Annalisa
    Paneroni, Mara
    Schreiber, Annia
    Pisani, Lara
    Ambrosino, Nicolino
    PULMONOLOGY, 2019, 25 (06): : 328 - 333
  • [35] Late Breaking Abstract - The efficacy of heated humidifier high-flow nasal cannula compared with noninvasive positive-pressure ventilation in prevention of reintubation in patients with prolonged mechanical ventilation
    Tseng, Chi-Wei
    Chao, Ke-Yun
    Chiang, Chen-En
    Liu, Wei-Lun
    Chou, Wen-Ru
    Wu, Hsiu-Li
    Lin, Chen-Chun
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [36] Organ recovery during prolonged mechanical ventilation
    White, A. C.
    Joseph, B.
    O'Connor, H.
    Nelson, J.
    Grandfield, J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [37] Influence of Ambient Temperature and Minute Ventilation on Passive and Active Heat and Moisture Exchangers
    Lellouche, Francois
    Qader, Siham
    Taille, Solenne
    Lyazidi, Aissam
    Brochard, Laurent
    RESPIRATORY CARE, 2014, 59 (05) : 637 - 643
  • [38] Respiratory gas conditioning with filters/heat and moisture exchangers can increase the duration of hyperthermia in patients under mechanical ventilation
    Urakov, Aleksandr
    Shchegolev, Aleksei
    Kasatkin, Anton
    MEDICAL GAS RESEARCH, 2020, 10 (01): : 60 - 60
  • [39] USE OF A HEAT AND MOISTURE EXCHANGER DURING LONG-TERM MECHANICAL VENTILATION - REPLY
    MISSET, B
    ESCUDIER, B
    RIVARA, D
    LECLERCQ, B
    NITENBERG, G
    CHEST, 1992, 102 (03) : 979 - 980
  • [40] Ventilator-associated pneumonia:: effects of heat moisture exchangers and heated water humidificators
    Lachérade, J
    Auburtin, M
    Soufir, L
    Van de Louw, A
    Cerf, C
    Rebufat, Y
    Reizzega, S
    Ricard, J
    Lellouche, F
    Lemaire, F
    Brun-Buisson, C
    Brochard, L
    INTENSIVE CARE MEDICINE, 2002, 28 : S132 - S132