COMPARISON OF HYDROPHOBIC HEAT AND MOISTURE EXCHANGERS WITH HEATED HUMIDIFIER DURING PROLONGED MECHANICAL VENTILATION

被引:105
|
作者
ROUSTAN, JP [1 ]
KIENLEN, J [1 ]
AUBAS, P [1 ]
AUBAS, S [1 ]
DUCAILAR, J [1 ]
机构
[1] HOP LAPEYRONIE, DEPT INFORMAT MED, F-34059 MONTPELLIER, FRANCE
关键词
EQUIPMENT; MECHANICAL VENTILATION; HEAT AND BACTERIAL FILTER;
D O I
10.1007/BF01705040
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Inspired gases must be warmed and humidified during mechanical ventilation. In a prospective randomized study we compared the performance of a heated humidifier (HH) (Draegger Aquaport) and a heat and moisture exchanger (HME) (Pall Filter BB 2215). A total of 116 patients requiring mechanical ventilation (Servo 900 C Siemens) were enrolled into the study and were randomly assigned to 2 groups. Patients in group I were ventilated with a traditional breathing circuit with HH and patients in group II using a simplified circuit with HME. Pre-existing and hospital acquired atelectasis and pneumonia, occurrence of endotracheal tube (ET) occlusion and ventilatory parameters (respiratory rate, tidal volume) were studied. No statistical difference was found between groups for each parameter except the greater frequency of ET occlusions in the II group (0/61 vs 9/55) (P = 0.0008). Pall Filter (PF), a hydrophobic filter, humidifies the dry gases from the condensed water which is put down on the HME surfaces during cooling of saturated expired gases. This purely physical property is linked to the magnitude of the thermic gradient between the expired gases and the ambient temperature. Performance impairment of PF in our study might be due to high ambient temperature in the intensive care unit (usually around 28-degrees-C) which reduces thermic gradient and water exchanges. We conclude that efficiency of PF may be weak in some conditions of ambient temperature.
引用
收藏
页码:97 / 100
页数:4
相关论文
共 50 条
  • [1] Small dead space heat and moisture exchangers do not impede gas exchange during noninvasive ventilation: a comparison with a heated humidifier
    Boyer, Alexandre
    Vargas, Frederic
    Hilbert, Gilles
    Gruson, Didier
    Mousset-Hovaere, Maud
    Castaing, Yves
    Dreyfuss, Didier
    Ricard, Jean Damien
    INTENSIVE CARE MEDICINE, 2010, 36 (08) : 1348 - 1354
  • [2] Small dead space heat and moisture exchangers do not impede gas exchange during noninvasive ventilation: a comparison with a heated humidifier
    Alexandre Boyer
    Frederic Vargas
    Gilles Hilbert
    Didier Gruson
    Maud Mousset-Hovaere
    Yves Castaing
    Didier Dreyfuss
    Jean Damien Ricard
    Intensive Care Medicine, 2010, 36 : 1348 - 1354
  • [3] Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation
    LeBourdelles, G
    Mier, L
    Fiquet, B
    Djedaini, K
    Saumon, G
    Coste, F
    Dreyfuss, D
    CHEST, 1996, 110 (05) : 1294 - 1298
  • [4] Effects of a heat and moisture exchanger and a heated humidifier on respiratory mucus in patients undergoing mechanical ventilation
    Nakagawa, NK
    Macchione, M
    Petrolino, HMS
    Guimaraes, ET
    King, M
    Saldiva, PHN
    Lorenzi, G
    CRITICAL CARE MEDICINE, 2000, 28 (02) : 312 - 317
  • [5] HEAT AND MOISTURE EXCHANGER VS HEATED HUMIDIFIER DURING LONG-TERM MECHANICAL VENTILATION - A PROSPECTIVE RANDOMIZED STUDY
    MISSET, B
    ESCUDIER, B
    RIVARA, D
    LECLERCQ, B
    NITENBERG, G
    CHEST, 1991, 100 (01) : 160 - 163
  • [6] Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during non-invasive ventilation
    Jaber, S
    Chanques, G
    Matecki, S
    Ramonatxo, M
    Souche, B
    Perrigault, PF
    Eledjam, JJ
    INTENSIVE CARE MEDICINE, 2002, 28 (11) : 1590 - 1594
  • [7] Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during non-invasive ventilation
    Samir Jaber
    Gérald Chanques
    Stefan Matecki
    Michèle Ramonatxo
    Bruno Souche
    Pierre-François Perrigault
    Jean-Jacques Eledjam
    Intensive Care Medicine, 2002, 28 : 1590 - 1594
  • [8] MECHANICAL VENTILATION WITH HEATED HUMIDIFIERS OR HEAT AND MOISTURE EXCHANGERS - EFFECTS ON PATIENT COLONIZATION AND INCIDENCE OF NOSOCOMIAL PNEUMONIA
    DREYFUSS, D
    DJEDAINI, K
    GROS, I
    MIER, L
    LEBOURDELLES, G
    COHEN, Y
    ESTAGNASIE, P
    COSTE, F
    BOUSSOUGANT, Y
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 151 (04) : 986 - 992
  • [9] AEROSOL DELIVERY FROM THE DRY SIDE OF A HEATED HUMIDIFIER DURING MECHANICAL VENTILATION
    Lee, Janice A.
    McPeck, Michael
    Cuccia, Ann D.
    Smaldone, Gerald C.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2021, 34 (05) : A18 - A18
  • [10] IMPACT OF VENTILATOR SETTINGS ON HYGROMETRIC PERFORMANCES OF HEATED-WIRE HEATED HUMIDIFIER DURING MECHANICAL VENTILATION
    Lellouche, Francois
    Bouchard, Pie
    CHEST, 2024, 166 (04) : 3042A - 3042A