Quantitative measurement of airway dimensions using ultra-high resolution computed tomography

被引:34
|
作者
Tanabe, Naoya [1 ]
Oguma, Tsuyoshi [1 ]
Sato, Susumu [1 ]
Kubo, Takeshi [2 ]
Kozawa, Satoshi [3 ]
Shima, Hiroshi [1 ]
Koizumi, Koji [3 ]
Sato, Atsuyasu [1 ]
Muro, Shigeo [1 ]
Togashi, Kaori [2 ]
Hirai, Toyohiro [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Resp Med, Sakyo Ku, 54 Kawahara Cho, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, 54 Kawahara Cho, Kyoto 6068507, Japan
[3] Kyoto Univ Hosp, Div Clin Radiol Serv, Sakyo Ku, 54 Kawahara Cho, Kyoto 6068507, Japan
关键词
Ultra-high resolution computed tomography; Lung; Airway; Chronic obstructive pulmonary disease; Asthma;
D O I
10.1016/j.resinv.2018.07.008
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Quantitative measurement of airway dimensions using computed tomography (CT) is performed in relatively larger airways due to the limited resolution of CT scans. Nevertheless, the small airway is an important pathological lesion in lung diseases such as chronic obstructive pulmonary disease (COPD) and asthma. Ultra-high resolution scanning may resolve the smaller airway, but its accuracy and limitations are unclear. Methods: Phantom tubes were imaged using conventional (512 x 512) and ultra-high resolution (1024 x 1024 and 2048 x 2048) scans. Reconstructions were performed using the forward-projected model-based iterative reconstruction solution (FIRST) algorithm in 512 x 512 and 1024 x 1024 matrix scans and the adaptive iterative dose reduction 3D (AIDR-3D) algorithm for all scans. In seven subjects with COPD, the airway dimensions were measured using the 1024 x 1024 and 512 x 512 matrix scans. Results: Compared to the conventional 512 x 512 scan, variations in the CT values for air were increased in the ultra-high resolution scans, except in the 1024 x 1024 scan reconstructed through FIRST. The measurement error of the lumen area of the tube with 2-mm diameter and 0.5-mm wall thickness (WT) was minimal in the ultra-high resolution scans, but not in the conventional 512 x 512 scan. In contrast to the conventional scans, the ultra-high resolution scans resolved the phantom tube with >= 0.6-mm WT at an error rate of < 11%. In seven subjects with COPD, the WT showed a lower value with the 1024 x 1024 scans versus the 512 x 512 scans. Conclusions: The ultra-high resolution scan may allow more accurate measurement of the bronchioles with smaller dimensions compared with the conventional scan. (C) 2018 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:489 / 496
页数:8
相关论文
共 50 条
  • [31] QUANTITATIVE IMAGING OF HIGH RESOLUTION COMPUTED TOMOGRAPHY OF THE CHEST
    Goldin, Jonathan
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2010, 28 (02) : S74 - S74
  • [32] Noise reduction and image quality in ultra-high resolution computed tomography of the temporal bone using advanced modeled iterative reconstruction
    Hempel, Johann-Martin
    Bongers, Malte Niklas
    Braun, Katharina
    Ernemann, Ulrike
    Bier, Georg
    ACTA RADIOLOGICA, 2019, 60 (09) : 1135 - 1143
  • [33] AN ULTRA-HIGH RESOLUTION PRECLINICAL POSITRON EMISSION TOMOGRAPHY SCANNER
    Martins, P.
    Blanco, A.
    arques, Crespo P.
    Marques, M. F. F.
    Marques, R. F.
    Gordo, P. M.
    Kajetanowicz, M.
    Korcyl, G.
    Lopes, L.
    Michel, J.
    Palka, M.
    Traxler, M.
    Abrunhosa, A. J.
    Couceiro, M.
    Fonte, P.
    2015 IEEE 4TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2015,
  • [34] Accuracy and Repeatability of Ultra-High Resolution Optical Coherence Tomography
    Hutchings, N.
    Hyun, C.
    Mishra, A.
    Bizheva, K.
    Simpson, T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [35] INVIVO MEASUREMENTS OF AIRWAY REACTIVITY USING HIGH-RESOLUTION COMPUTED-TOMOGRAPHY
    BROWN, RH
    HEROLD, CJ
    HIRSHMAN, CA
    ZERHOUNI, EA
    MITZNER, W
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 144 (01): : 208 - 212
  • [36] Improvement of Neurovascular Imaging Using Ultra-High-Resolution Computed Tomography Angiography
    Felix A. Ucar
    Marius Frenzel
    Andrea Kronfeld
    Sebastian Altmann
    Antoine P. Sanner
    Mario Alberto Abello Mercado
    Timo Uphaus
    Marc A. Brockmann
    Ahmed E. Othman
    Clinical Neuroradiology, 2024, 34 : 189 - 199
  • [37] Improvement of Neurovascular Imaging Using Ultra-High-Resolution Computed Tomography Angiography
    Ucar, Felix A.
    Frenzel, Marius
    Kronfeld, Andrea
    Altmann, Sebastian
    Sanner, Antoine P.
    Mercado, Mario Alberto Abello
    Uphaus, Timo
    Brockmann, Marc A.
    Othman, Ahmed E.
    CLINICAL NEURORADIOLOGY, 2024, 34 (01) : 189 - 199
  • [38] Assessment of gastric wall structure using ultra-high-resolution computed tomography
    Onoda, Hideko
    Tanabe, Masahiro
    Higashi, Mayumi
    Kawano, Yosuke
    Ihara, Kenichiro
    Miyoshi, Keisuke
    Ito, Katsuyoshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 146
  • [39] Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality
    MacNeil, Joshua A.
    Boyd, Steven K.
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (06) : 792 - 799