Quantitative measurement of airway dimensions using ultra-high resolution computed tomography

被引:34
|
作者
Tanabe, Naoya [1 ]
Oguma, Tsuyoshi [1 ]
Sato, Susumu [1 ]
Kubo, Takeshi [2 ]
Kozawa, Satoshi [3 ]
Shima, Hiroshi [1 ]
Koizumi, Koji [3 ]
Sato, Atsuyasu [1 ]
Muro, Shigeo [1 ]
Togashi, Kaori [2 ]
Hirai, Toyohiro [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Resp Med, Sakyo Ku, 54 Kawahara Cho, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, 54 Kawahara Cho, Kyoto 6068507, Japan
[3] Kyoto Univ Hosp, Div Clin Radiol Serv, Sakyo Ku, 54 Kawahara Cho, Kyoto 6068507, Japan
关键词
Ultra-high resolution computed tomography; Lung; Airway; Chronic obstructive pulmonary disease; Asthma;
D O I
10.1016/j.resinv.2018.07.008
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Quantitative measurement of airway dimensions using computed tomography (CT) is performed in relatively larger airways due to the limited resolution of CT scans. Nevertheless, the small airway is an important pathological lesion in lung diseases such as chronic obstructive pulmonary disease (COPD) and asthma. Ultra-high resolution scanning may resolve the smaller airway, but its accuracy and limitations are unclear. Methods: Phantom tubes were imaged using conventional (512 x 512) and ultra-high resolution (1024 x 1024 and 2048 x 2048) scans. Reconstructions were performed using the forward-projected model-based iterative reconstruction solution (FIRST) algorithm in 512 x 512 and 1024 x 1024 matrix scans and the adaptive iterative dose reduction 3D (AIDR-3D) algorithm for all scans. In seven subjects with COPD, the airway dimensions were measured using the 1024 x 1024 and 512 x 512 matrix scans. Results: Compared to the conventional 512 x 512 scan, variations in the CT values for air were increased in the ultra-high resolution scans, except in the 1024 x 1024 scan reconstructed through FIRST. The measurement error of the lumen area of the tube with 2-mm diameter and 0.5-mm wall thickness (WT) was minimal in the ultra-high resolution scans, but not in the conventional 512 x 512 scan. In contrast to the conventional scans, the ultra-high resolution scans resolved the phantom tube with >= 0.6-mm WT at an error rate of < 11%. In seven subjects with COPD, the WT showed a lower value with the 1024 x 1024 scans versus the 512 x 512 scans. Conclusions: The ultra-high resolution scan may allow more accurate measurement of the bronchioles with smaller dimensions compared with the conventional scan. (C) 2018 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:489 / 496
页数:8
相关论文
共 50 条
  • [21] Detectability of the artery of Adamkiewicz on computed tomography angiography of the aorta by using ultra-high-resolution computed tomography
    Takuya Hino
    Takeshi Kamitani
    Koji Sagiyama
    Yuzo Yamasaki
    Yuko Matsuura
    Soichiro Tsutsui
    Yuki Sakai
    Tadashi Furuyama
    Hidetake Yabuuchi
    Japanese Journal of Radiology, 2020, 38 : 658 - 665
  • [22] Detectability of the artery of Adamkiewicz on computed tomography angiography of the aorta by using ultra-high-resolution computed tomography
    Hino, Takuya
    Kamitani, Takeshi
    Sagiyama, Koji
    Yamasaki, Yuzo
    Matsuura, Yuko
    Tsutsui, Soichiro
    Sakai, Yuki
    Furuyama, Tadashi
    Yabuuchi, Hidetake
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (07) : 658 - 665
  • [23] Preliminary evaluation of ultra-high pitch computed tomography enterography
    Hardie, Andrew D.
    Horst, Nicole D.
    Mayes, Nicholas
    ACTA RADIOLOGICA, 2012, 53 (10) : 1088 - 1091
  • [24] Quantitative Assessment of Airway Pathology in Subjects With COPD Using Low-Dose High-Resolution Computed Tomography
    Chen, Huai
    Chen, Gai-qun
    Zeng, Qing-si
    Xia, Ting-ting
    Zhou, Jia-xuan
    Qiu, Shi-jun
    RESPIRATORY CARE, 2017, 62 (07) : 953 - 962
  • [25] Spectral domain optical coherence tomography - Ultra-high speed, ultra-high resolution ophthalmic imaging
    Chen, TC
    Cense, B
    Pierce, MC
    Nassif, N
    Park, BH
    Yun, SH
    White, BR
    Bouma, BE
    Tearney, GJ
    de Boer, JF
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (12) : 1715 - 1720
  • [26] Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality
    MacNeil, Joshua A.
    Boyd, Steven K.
    MEDICAL ENGINEERING & PHYSICS, 2007, 29 (10) : 1096 - 1105
  • [27] Ultra-high Resolution Phase Difference Measurement Method
    Dong, Shaofeng
    Zhou, Wei
    Du, Baoqiang
    Jiao, Changzhe
    2012 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (FCS), 2012,
  • [28] Absence of pontine perforators in vertebrobasilar dolichoectasia on ultra-high resolution cone-beam computed tomography
    Dobrocky, Tomas
    Piechowiak, Eike, I
    Goldberg, Johannes
    Aleman, Enrique Barvulsky
    Nicholson, Patrick
    Lynch, Jeremy
    Bervini, David
    Kaesmacher, Johannes
    Agid, Ronit
    Krings, Timo
    Raabe, Andreas
    Gralla, Jan
    Pereira, Vitor M.
    Mordasini, Pasquale
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (06) : 580 - +
  • [29] Calibration of helical computed tomography for analysis of kidney stone structure - Comparison with ultra-high resolution CT
    Paterson, RF
    Lingeman, JE
    Tann, MA
    Persohn, SA
    Hatt, EK
    Evan, AP
    McAteer, JA
    Williams, JC
    JOURNAL OF UROLOGY, 2002, 167 (04): : 360 - 360
  • [30] Measurement of the retention time of different ophthalmic formulations with ultra-high resolution Optical Coherence Tomography
    Amato, Roberta
    Gagliano, Caterina
    Malaguarnera, Giulia
    Reibaldi, Michele
    Longo, Antonio
    Papa, Vincenzo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)