CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP

被引:1040
|
作者
HARRISON, DJ [1 ]
MANZ, A [1 ]
FAN, ZH [1 ]
LUDI, H [1 ]
WIDMER, HM [1 ]
机构
[1] CIBA GEIGY AG,FORSCH ANALYT,CH-4002 BASEL,SWITZERLAND
关键词
D O I
10.1021/ac00041a030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of miniaturizing a chemical analysis system on a planar substrate has been demonstrated for a system utilizing electrokinetic phenomena for sample separation and solvent pumping. Using micromachining techniques, a complex manifold of capillary channels has been fabricated in a planar glass substrate and the separation of a mixture of fluorescein and caicein within the channels was achieved using electrophoresis. The maximum number of theoretical plates obtained was about 35 000 for caicein, with 5000 V applied, corresponding to 2100 V between the injection and fluorescence detection points in the channels. The number of theoretical plates observed was in agreement with theory, indicating no interactions between the analyte and the glass walls. The electroosmotic flow rate in the glass channels was (4.5 +/- 0.1) X 10(-4) cm2/(V.s) using a pH 8.5 50 mM boric acid, 50 mM Tris buffer, comparable to (5.87 +/- 0.08) X 10(-4) cm2/(V.s) measured in fused-silica capillaries. Solvent flow could be directed along a specified capillary by application of appropriate voltages, so that valveless switching of fluid flow between capillaries could be achieved. These results provide a foundation for the design of more complex sample treatment and separation systems Integrated on glass or silicon substrates.
引用
收藏
页码:1926 / 1932
页数:7
相关论文
共 50 条
  • [31] Acupuncture Sample Injection for Microchip Capillary Electrophoresis and Electrokinetic Chromatography
    Ha, Ji Won
    Hahn, Jong Hoon
    ANALYTICAL CHEMISTRY, 2016, 88 (09) : 4629 - 4634
  • [32] Class chips for capillary electrophoresis: Micromachining, sample injection and separation
    Tang, YH
    Ye, XY
    Zhou, ZY
    Jin, Y
    Feng, YY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (05) : 606 - 610
  • [33] ZONE BROADENING DUE TO SAMPLE INJECTION IN CAPILLARY ZONE ELECTROPHORESIS
    GRUSHKA, E
    MCCORMICK, RM
    JOURNAL OF CHROMATOGRAPHY, 1989, 471 : 421 - 428
  • [34] Combination of sample pre-concentration and capillary electrophoresis on-chip
    Lichtenberg, J
    Daridon, A
    Verpoorte, E
    de Rooij, NF
    MICRO TOTAL ANALYSIS SYSTEMS 2000, PROCEEDINGS, 2000, : 307 - 310
  • [35] Sample introduction techniques for microfluidic chip-based capillary electrophoresis
    He Qiaohong
    Fang Qun
    Fang Zhaolun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (05) : 729 - 734
  • [36] Integrated sample injection chip for Micro-HPLC
    Ezaki, Takahiro
    Yamazaki, Takeo
    Yasuda, Susumu
    Yagi, Takayuki
    2006 1ST IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2006, : 979 - +
  • [37] Coupling continuous sample treatment systems to capillary electrophoresis
    Valcarcel, M
    Rios, A
    Arce, L
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1998, 28 (01) : 63 - 81
  • [38] Developments in flow injection-capillary electrophoresis systems
    Fang, ZL
    Chen, HW
    Fang, Q
    Pu, QS
    ANALYTICAL SCIENCES, 2000, 16 (02) : 197 - 203
  • [39] QUANTITATIVE STUDIES OF DIFFERENT INJECTION SYSTEMS IN CAPILLARY ELECTROPHORESIS
    ERMAKOV, SV
    ZHUKOV, MY
    CAPELLI, L
    RIGHETTI, PG
    ELECTROPHORESIS, 1994, 15 (8-9) : 1158 - 1166
  • [40] Influence of the sample volume and the position of the electrode and the capillary-end in the sample vial on the electrokinetic injection in capillary electrophoresis
    deBoer, T
    Ensing, K
    JOURNAL OF CHROMATOGRAPHY A, 1997, 788 (1-2) : 212 - 217