CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP

被引:1040
|
作者
HARRISON, DJ [1 ]
MANZ, A [1 ]
FAN, ZH [1 ]
LUDI, H [1 ]
WIDMER, HM [1 ]
机构
[1] CIBA GEIGY AG,FORSCH ANALYT,CH-4002 BASEL,SWITZERLAND
关键词
D O I
10.1021/ac00041a030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of miniaturizing a chemical analysis system on a planar substrate has been demonstrated for a system utilizing electrokinetic phenomena for sample separation and solvent pumping. Using micromachining techniques, a complex manifold of capillary channels has been fabricated in a planar glass substrate and the separation of a mixture of fluorescein and caicein within the channels was achieved using electrophoresis. The maximum number of theoretical plates obtained was about 35 000 for caicein, with 5000 V applied, corresponding to 2100 V between the injection and fluorescence detection points in the channels. The number of theoretical plates observed was in agreement with theory, indicating no interactions between the analyte and the glass walls. The electroosmotic flow rate in the glass channels was (4.5 +/- 0.1) X 10(-4) cm2/(V.s) using a pH 8.5 50 mM boric acid, 50 mM Tris buffer, comparable to (5.87 +/- 0.08) X 10(-4) cm2/(V.s) measured in fused-silica capillaries. Solvent flow could be directed along a specified capillary by application of appropriate voltages, so that valveless switching of fluid flow between capillaries could be achieved. These results provide a foundation for the design of more complex sample treatment and separation systems Integrated on glass or silicon substrates.
引用
收藏
页码:1926 / 1932
页数:7
相关论文
共 50 条
  • [21] A falling drop for sample injection in capillary zone electrophoresis
    Liu, HH
    Dasgupta, PK
    ANALYTICAL CHEMISTRY, 1997, 69 (06) : 1211 - 1216
  • [22] APPLICATION OF SAMPLE STACKING TO GRAVITY INJECTION IN CAPILLARY ELECTROPHORESIS
    BURGI, DS
    CHIEN, RL
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1991, 3 (03) : 199 - 202
  • [23] Isoelectric focusing sample injection for capillary electrophoresis of proteins
    Wu, XZ
    Zhang, LH
    Onoda, K
    ELECTROPHORESIS, 2005, 26 (03) : 563 - 570
  • [24] PLANAR CHIPS TECHNOLOGY FOR MINIATURIZATION AND INTEGRATION OF SEPARATION TECHNIQUES INTO MONITORING SYSTEMS - CAPILLARY ELECTROPHORESIS ON A CHIP
    MANZ, A
    HARRISON, DJ
    VERPOORTE, EMJ
    FETTINGER, JC
    PAULUS, A
    LUDI, H
    WIDMER, HM
    JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2): : 253 - 258
  • [25] Field amplified sample stacking coupled with chip-based capillary electrophoresis using negative pressure sample injection technique
    Zhang, Lei
    Yin, Xue-Feng
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1137 (02) : 243 - 248
  • [26] Computer numerical analysis of electrokinetic injection in chip capillary electrophoresis
    Yan, WP
    Zheng, JW
    Wang, J
    Liu, C
    Bai, JL
    2003 THIRD IEEE CONFERENCE ON NANOTECHNOLOGY, VOLS ONE AND TWO, PROCEEDINGS, 2003, : 705 - 708
  • [27] Acupuncture injection for field amplified sample stacking and glass microchip-based capillary gel electrophoresis
    Ha, Ji Won
    Hahn, Jong Hoon
    ELECTROPHORESIS, 2017, 38 (3-4) : 521 - 524
  • [28] Developments in Flow Injection—Capillary Electrophoresis Systems
    Zhao-Lun Fang
    Heng-Wu Chen
    Qun Fang
    Qiao-Sheng Pu
    Analytical Sciences, 2000, 16 : 197 - 203
  • [29] Isoelectric focusing sample injection for capillary zone electrophoresis in a fused silica capillary
    Zhang, Luo-Hong
    Zhang, Cheng-Jie
    Wu, Xing-Zheng
    ANALYTICAL SCIENCES, 2006, 22 (07) : 1039 - 1041
  • [30] Isoelectric Focusing Sample Injection for Capillary Zone Electrophoresis in a Fused Silica Capillary
    Luo-Hong Zhang
    Cheng-Jie Zhang
    Xing-Zheng Wu