CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP

被引:1040
|
作者
HARRISON, DJ [1 ]
MANZ, A [1 ]
FAN, ZH [1 ]
LUDI, H [1 ]
WIDMER, HM [1 ]
机构
[1] CIBA GEIGY AG,FORSCH ANALYT,CH-4002 BASEL,SWITZERLAND
关键词
D O I
10.1021/ac00041a030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of miniaturizing a chemical analysis system on a planar substrate has been demonstrated for a system utilizing electrokinetic phenomena for sample separation and solvent pumping. Using micromachining techniques, a complex manifold of capillary channels has been fabricated in a planar glass substrate and the separation of a mixture of fluorescein and caicein within the channels was achieved using electrophoresis. The maximum number of theoretical plates obtained was about 35 000 for caicein, with 5000 V applied, corresponding to 2100 V between the injection and fluorescence detection points in the channels. The number of theoretical plates observed was in agreement with theory, indicating no interactions between the analyte and the glass walls. The electroosmotic flow rate in the glass channels was (4.5 +/- 0.1) X 10(-4) cm2/(V.s) using a pH 8.5 50 mM boric acid, 50 mM Tris buffer, comparable to (5.87 +/- 0.08) X 10(-4) cm2/(V.s) measured in fused-silica capillaries. Solvent flow could be directed along a specified capillary by application of appropriate voltages, so that valveless switching of fluid flow between capillaries could be achieved. These results provide a foundation for the design of more complex sample treatment and separation systems Integrated on glass or silicon substrates.
引用
收藏
页码:1926 / 1932
页数:7
相关论文
共 50 条
  • [1] PLANAR GLASS CHIPS FOR CAPILLARY ELECTROPHORESIS - REPETITIVE SAMPLE INJECTION, QUANTITATION, AND SEPARATION EFFICIENCY
    SEILER, K
    HARRISON, DJ
    MANZ, A
    ANALYTICAL CHEMISTRY, 1993, 65 (10) : 1481 - 1488
  • [2] Sample injection for capillary electrophoresis on a micro fabricated device/on chip CE injection
    Wenclawiak, BW
    Püschl, R
    ANALYTICAL LETTERS, 2006, 39 (01) : 3 - 16
  • [3] PLANAR CHIP TECHNOLOGY FOR CAPILLARY ELECTROPHORESIS
    MANZ, A
    VERPOORTE, E
    EFFENHAUSER, CS
    BURGGRAF, N
    RAYMOND, DE
    WIDMER, HM
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (8-9): : 567 - 571
  • [4] A capillary electrophoresis chip with hydrodynamic sample injection for measurements from a continuous sample flow
    S. Büttgenbach
    R. Wilke
    Analytical and Bioanalytical Chemistry, 2005, 383 : 733 - 737
  • [5] Sample matrix effects on injection and sample loading in integrated capillary electrophoresis devices
    Shultz-Lockyear, LL
    Colyer, CL
    Roy, KI
    Harrison, DJ
    MICRO TOTAL ANALYSIS SYSTEMS '98, 2000, : 169 - 172
  • [6] A capillary electrophoresis chip with hydrodynamic sample injection for measurements from a continuous sample flow
    Büttgenbach, S
    Wilke, R
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (05) : 733 - 737
  • [7] Quantitative sample injection for capillary electrophoresis
    Yao, CY
    Gao, RY
    Yan, C
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (1-2): : 37 - 42
  • [8] ELECTROPHORESIS AND SAMPLE HANDLING ON A GLASS CHIP
    HARRISON, DJ
    FLURI, K
    FAN, Z
    SEILER, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 157 - ANYL
  • [9] Numerical Simulation and Experimental Validation of Electrokinetic Injection for Integrated Capillary Electrophoresis Chip
    Yan Weiping Li Henan Chen Liming Chen Haijun Deptof Electronic EngineeringDalian University of TechnologyDalian China Center of Analyse and TestDalian Medical UniversityDalian China
    稀有金属材料与工程, 2006, (S3) : 552 - 555
  • [10] Numerical simulation and experimental validation of electrokinetic injection for integrated capillary electrophoresis chip
    Yan Weiping
    Li Henan
    Chen Liming
    Chen Haijun
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 552 - 555