ENANTIOSPECIFIC ANALYSIS OF KETOPROFEN IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:26
|
作者
HAYBALL, PJ
NATION, RL
BOCHNER, F
LELEU, RK
机构
[1] UNIV ADELAIDE,DEPT CLIN & EXPTL PHARMACOL,ADELAIDE,SA 5000,AUSTRALIA
[2] UNIV S AUSTRALIA,SCH PHARM,ADELAIDE,SA 5000,AUSTRALIA
来源
基金
英国医学研究理事会;
关键词
D O I
10.1016/0378-4347(91)80552-N
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatographic (HPLC) assay for the determination of the R- and S-enantiomers of ketoprofen is described. Facile ketoprofen extraction from plasma and derivatization to the diastereomeric S-1-phenylethylamides was followed by normal-phase HPLC. The ketoprofen diastereomeric amides eluted within 8 min. The limit of quantification of the assay was 0.15 mg/l of each enantiomer (signal-to-noise ratio = 5).
引用
收藏
页码:446 / 452
页数:7
相关论文
共 50 条
  • [1] DETERMINATION OF KETOPROFEN IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    JEFFERIES, TM
    THOMAS, WOA
    PARFITT, RT
    JOURNAL OF CHROMATOGRAPHY, 1979, 162 (01): : 122 - 124
  • [2] PURITY ASSAY OF KETOPROFEN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PIETTA, P
    MANERA, E
    CEVA, P
    JOURNAL OF CHROMATOGRAPHY, 1987, 387 : 525 - 527
  • [3] DETERMINATION OF KETOPROFEN IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - COMPARISON WITH GAS-LIQUID-CHROMATOGRAPHY
    BANNIER, A
    BRAZIER, JL
    RIBON, B
    JOURNAL OF CHROMATOGRAPHY, 1978, 155 (02): : 371 - 378
  • [4] ANALYSIS OF PREDNISOLONE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LOO, JCK
    BUTTERFIELD, AG
    MOFFATT, J
    JORDAN, N
    JOURNAL OF CHROMATOGRAPHY, 1977, 143 (03): : 275 - 280
  • [5] ANALYSIS OF DOXYLAMINE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KOHLHOF, KJ
    STUMP, D
    ZIZZAMIA, JA
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1983, 72 (08) : 961 - 962
  • [6] ANALYSIS OF PIROXICAM IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TWOMEY, TM
    BARTOLUCCI, SR
    HOBBS, DC
    JOURNAL OF CHROMATOGRAPHY, 1980, 183 (01): : 104 - 108
  • [7] ANALYSIS OF NORETHINDRONE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LOO, JCK
    BRIEN, R
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1981, 4 (05): : 871 - 877
  • [8] QUANTITATION OF KETOPROFEN IN ISOPROPYL MYRISTATE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CHI, SC
    JUN, HW
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1989, 12 (15): : 2931 - 2945
  • [9] SIMULTANEOUS DETERMINATION OF KETOPROFEN ENANTIOMERS AND PROBENECID IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PALYLYK, EL
    JAMALI, F
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 568 (01): : 187 - 196
  • [10] CHIRAL ANALYSIS OF METHADONE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BECK, O
    BOREUS, LO
    LAFOLIE, P
    JACOBSSON, G
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (01): : 198 - 202