A Monte Carlo simulation of coincidence detection and imaging of gamma-ray cascades with a scintillation camera

被引:4
|
作者
Pahlka, R. Benton [1 ]
Kappadath, S. Cheenu [1 ]
Mawlawi, Osama R. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, UNIT 1472, POB 301402, Houston, TX 77230 USA
来源
关键词
gamma-ray cascades; coincidence detection; gamma camera;
D O I
10.1088/2057-1976/aad572
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Several radionuclei used in nuclear medicine decay through the emission of cascaded gamma-rays. These successively-emitted gamma-rays could potentially be detected in coincidence and then be used to create coincident event-based images. While several groups have considered various ways to leverage the gamma-ray cascade to produce images, the concept of producing images using cascaded gamma rays in coincidence with a dual-head gamma camera has not been previously explored in detail. Given that current dual-head gamma cameras cannot be configured in coincidence mode, the purpose of this work was to explore this concept with In-111 using a Monte Carlo simulation. First, GEANT4 was used to model a dual-head gamma camera and to simulate the decay of the nucleus. The model was then validated using planar data from a physical scanner. The validated model was then used to simulate a point source of In-111 located at the camera isocenter to evaluate the true coincidence efficiency with the detectors oriented at 90 degrees. The noise-equivalent-count-rate (NECR) as a function of timing window resolution was computed for different source activities. A simple reconstruction algorithm was then used to produce coincidence-based images from sources in various configurations. The coincident gamma-ray detection efficiency for a single point source in air with the detector heads oriented at 90 degrees was found to be 6 x 10(-8), independent of the source-to-detector distance. The time window resolution for the maximum NECR ranged between 200 and 500 ns, dependent on source activity. The algorithm could produce images over a range of timing window resolutions, with varying levels of reconstruction artifacts. Images produced from a small acrylic phantom showed that scattered events produced small degradations in resolution and contrast-to-noise ratios. This work described the conditions under which images based on coincident events from In-111 could be created using a dual head gamma camera, assuming appropriate electronics modifications.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Monte Carlo simulation of induced radioactive background in gamma-ray detector materials
    Truscott, PR
    Evans, HE
    Dyer, CS
    Cosby, M
    Knight, PR
    Moss, CE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 894 - 902
  • [42] A Monte Carlo simulation method for polarized gamma-ray nuclear resonance fluorescence
    Chi, Zhijun
    Zhang, Hongze
    Lin, Jin
    Zhang, Xuanqi
    Ding, Hao
    Zhang, Zhi
    Du, Yingchao
    Huang, Wenhui
    Tang, Chuanxiang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1056
  • [43] Performance of In-111 Coincident Gamma-Ray Counting: A Monte Carlo Simulation
    Pahlka, R.
    Kappadath, S.
    Mawlawi, O.
    MEDICAL PHYSICS, 2016, 43 (06) : 3680 - 3680
  • [44] Use of Monte Carlo simulation to examine gamma-ray interactions in germanium detectors
    Kamboj, S
    Kahn, B
    RADIATION MEASUREMENTS, 2003, 37 (01) : 1 - 8
  • [45] Monte Carlo simulation for multi-channel gamma-ray process tomography
    Mosorov, V.
    Johansen, G. A.
    Maad, R.
    Sankowski, D.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (05)
  • [46] APPLICATIONS OF GAMMA-RAY SCINTILLATION CAMERA TO DYNAMIC STUDIES IN MAN
    ROSENTHAL, L
    JOURNAL OF NUCLEAR MEDICINE, 1966, 7 (05) : 386 - +
  • [47] APPLICATIONS OF GAMMA-RAY SCINTILLATION CAMERA TO DYNAMIC STUDIES IN MAN
    ROSENTHALL, L
    RADIOLOGY, 1966, 86 (04) : 634 - +
  • [48] MONTE-CARLO CALCULATIONS OF GAMMA-RAY BACKSCATTERING
    GAYER, A
    BUKSHPAN, S
    NARDI, E
    NUCLEAR INSTRUMENTS & METHODS, 1981, 180 (2-3): : 589 - 595
  • [49] MONTE-CARLO CALCULATIONS OF GAMMA-RAY BACKSCATTERING
    BERGER, MJ
    RASO, DJ
    RADIATION RESEARCH, 1960, 12 (01) : 20 - 37
  • [50] MGGPOD: A Monte Carlo suite for gamma-ray astronomy
    Weidenspointner, G
    Harris, M
    Ferguson, C
    Sturner, S
    Teegarden, B
    Wunderer, C
    PROCEEDINGS OF THE 5TH INTEGRAL WORKSHOP ON THE INTEGRAL UNIVERSE, 2004, 552 : 905 - 908