Negative effect of seroma on breast balloon brachytherapy dosimetry

被引:2
|
作者
Bhatt, Aashish D. [1 ]
Barry, Parul N. [2 ]
Sowards, Keith T. [2 ]
Dragun, Anthony E. [2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, 1 Emerson Pl,Apt 3-O, Boston, MA 02114 USA
[2] Univ Louisville, Dept Radiat Oncol, Louisville, KY 40292 USA
关键词
D O I
10.1016/j.prro.2013.03.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Balloon brachytherapy is commonly used to deliver Accelerated Partial Breast Irradiation (APBI). Seroma interference is a relatively common phenomenon during APBI. The negative effect of seroma accumulation on the planning target volume evaluation (PTV_Eval) coverage is not well understood. Methods and Materials: This is a dosimetric replanning study on 10 patients with evidence of seroma collection at time of initial computed tomographic simulation around the catheter. Total dose was 34 Gy given at 3.4 Gy twice a day over 5 treatment days. A total of 20 plans were generated, 10 plans without accounting for and 10 after subtracting the seroma. We then compared the changes seen in PTV_Eval between plans as a factor of the seroma volume. Results: Median age was 62 years (51-83). Histology was invasive in 7/10 cases and in situ in 3/10. Median balloon to skin distance was 8.5 mm (3-14). Median balloon volume was 39 cc (30-104). Median seroma volumewas 3.34 cc (1.13-13.71). For every 1 cc of accumulated seroma the percentage of PTV_Eval coverage by the 90% isodose line (V90) was found to decrease by 2.45% (P < .0001; confidence interval [CI], 1.87-3.03) and coverage by the 100% isodose line (V100) was decreased by 1.11% (P < .0001; CI, 0.81-1.41). Fifty percent (5/10) of previously acceptable plans with seroma not accounted for failed to meet the V90 >= 90% requirement after subtracting the seroma. Conclusions: Accumulation of seroma was associated with a considerable negative impact on PTV_Eval dosimetry with a greater impact on V90 compared with the V100. Clinicians must be careful in detecting and accounting for such accumulation in treatment plans to prevent underdosing of the at risk target breast tissue. (C) 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:E1 / E5
页数:5
相关论文
共 50 条
  • [41] A post-implant dosimetry simulator for permanent breast seed implant brachytherapy
    Zhang, Claire
    Batchelar, Deidre
    Andrews, Jeff
    Crook, Juanita
    Hilts, Michelle
    MEDICAL PHYSICS, 2022, 49 (08) : 5700 - 5701
  • [42] High Energy Brachytherapy Dosimetry as It Applies to Accelerated Partial Breast Irradiation (APBI)
    Richardson, S.
    Mourtada, F.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [43] Reduction in Seroma and Other Complications with a Novel Internal Negative Pressure System in Breast Reconstruction
    Paul, Robert
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2023, 11 (09) : E5261
  • [44] DOSIMETRY METHODS IN HDR BRACHYTHERAPY
    Jakstas, Karolis
    Rudzianskas, Viktoras
    Adliene, Diana
    Sniureviciute, Migle
    Raila, Saulius
    MEDICAL PHYSICS IN THE BALTIC STATES, 2011, : 130 - 134
  • [45] Seroma in Prosthetic Breast Reconstruction
    Jordan, Sumanas W.
    Khavanin, Nima
    Kim, John Y. S.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2016, 137 (04) : 1104 - 1116
  • [46] PREVENTION OF SEROMA IN BREAST SURGERY
    Martinez Izquierdo, G.
    Calvo Rodriguez, D.
    Garcia Alonso, L.
    Ramos Montes, C.
    Ibero Casadiego, P.
    Menendez Corteguera, A.
    Alonso Martinez, B.
    Llaneza Folgueras, A.
    BRITISH JOURNAL OF SURGERY, 2023, 110
  • [47] Alanine EPR dosimetry in brachytherapy
    De Angelis, C
    Onori, S
    Petetti, E
    Piermattei, A
    Azario, L
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (05): : 1181 - 1191
  • [48] Quantitative dosimetry methods for brachytherapy
    Williamson, Jeffrey F.
    Rivard, Mark J.
    BRACHYTHERAPY PHYSICS, SECOND EDITION, 2005, (31): : 233 - 294
  • [49] Principles and practice of brachytherapy dosimetry
    Yue, Ning Jeff
    RADIATION MEASUREMENTS, 2006, 41 : S22 - S27
  • [50] Standards for intravascular brachytherapy dosimetry
    Soares, CG
    CELLULAR AND MOLECULAR BIOLOGY, 2002, 48 (05) : 441 - 443