Negative effect of seroma on breast balloon brachytherapy dosimetry

被引:2
|
作者
Bhatt, Aashish D. [1 ]
Barry, Parul N. [2 ]
Sowards, Keith T. [2 ]
Dragun, Anthony E. [2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, 1 Emerson Pl,Apt 3-O, Boston, MA 02114 USA
[2] Univ Louisville, Dept Radiat Oncol, Louisville, KY 40292 USA
关键词
D O I
10.1016/j.prro.2013.03.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Balloon brachytherapy is commonly used to deliver Accelerated Partial Breast Irradiation (APBI). Seroma interference is a relatively common phenomenon during APBI. The negative effect of seroma accumulation on the planning target volume evaluation (PTV_Eval) coverage is not well understood. Methods and Materials: This is a dosimetric replanning study on 10 patients with evidence of seroma collection at time of initial computed tomographic simulation around the catheter. Total dose was 34 Gy given at 3.4 Gy twice a day over 5 treatment days. A total of 20 plans were generated, 10 plans without accounting for and 10 after subtracting the seroma. We then compared the changes seen in PTV_Eval between plans as a factor of the seroma volume. Results: Median age was 62 years (51-83). Histology was invasive in 7/10 cases and in situ in 3/10. Median balloon to skin distance was 8.5 mm (3-14). Median balloon volume was 39 cc (30-104). Median seroma volumewas 3.34 cc (1.13-13.71). For every 1 cc of accumulated seroma the percentage of PTV_Eval coverage by the 90% isodose line (V90) was found to decrease by 2.45% (P < .0001; confidence interval [CI], 1.87-3.03) and coverage by the 100% isodose line (V100) was decreased by 1.11% (P < .0001; CI, 0.81-1.41). Fifty percent (5/10) of previously acceptable plans with seroma not accounted for failed to meet the V90 >= 90% requirement after subtracting the seroma. Conclusions: Accumulation of seroma was associated with a considerable negative impact on PTV_Eval dosimetry with a greater impact on V90 compared with the V100. Clinicians must be careful in detecting and accounting for such accumulation in treatment plans to prevent underdosing of the at risk target breast tissue. (C) 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:E1 / E5
页数:5
相关论文
共 50 条
  • [21] Deformable image registration for defining the postimplant seroma in permanent breast seed implant brachytherapy
    Hilts, Michelle
    Batchelar, Deidre
    Rose, Jim
    Crook, Juanita
    BRACHYTHERAPY, 2015, 14 (03) : 409 - 418
  • [22] The Incidence of Fat Necrosis in Balloon-Based Breast Brachytherapy
    Paryani, N. N.
    Vallow, L.
    Magalhaes, W.
    Heckman, M.
    Kim, S.
    Smith, A.
    Diehl, N.
    McLaughlin, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S208 - S208
  • [23] The incidence of fat necrosis in balloon-based breast brachytherapy
    Paryani, Nitesh N.
    Vallow, Laura
    Magalhaes, Wilza
    Heckman, Michael G.
    Kim, Siyong
    Smith, Ashley
    Diehl, Nancy N.
    McLaughlin, Sarah
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2015, 7 (01) : 29 - 34
  • [24] The MammoSite Balloon Brachytherapy catheter for accelerated partial breast irradiation
    Shah, NM
    Wazer, DE
    SEMINARS IN RADIATION ONCOLOGY, 2005, 15 (02) : 100 - 107
  • [25] Accelerated partial breast irradiation utilizing balloon brachytherapy techniques
    Strauss, Jonathan B.
    Dickler, Adam
    RADIOTHERAPY AND ONCOLOGY, 2009, 91 (02) : 157 - 165
  • [26] Isotope choice and the effect of edema on prostate brachytherapy dosimetry
    Butler, WM
    Merrick, GS
    Dorsey, AT
    Lief, JH
    MEDICAL PHYSICS, 2000, 27 (05) : 1067 - 1075
  • [27] Postoperative Seroma Formation Following Intraoperative Electronic Brachytherapy for Early-Stage Breast Cancer
    Facer, B.
    Brett, C.
    Morales, M.
    Grau, A. M.
    Sweeting, R.
    Meszoely, I.
    Chakravarthy, A. B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E41 - E41
  • [28] Seroma is an Expected Consequence and not a Complication of MammoSite Brachytherapy
    Patel, Priti S.
    Yan, Weisi
    Trichter, Sam
    Sabbas, Albert
    Rosenblatt, Ruth
    Drotman, Michele B.
    Swistel, Alexander
    Chao, K. S. Clifford
    Nori, Dattatreyudu
    Hayes, Mary Katherine
    BREAST JOURNAL, 2011, 17 (05): : 498 - 502
  • [29] ARGON BEAM COAGULATOR IN BREAST SURGERY: EFFECT ON THE INCIDENCE OF BREAST SEROMA
    Lefemine, V.
    Samra, W.
    EJC SUPPLEMENTS, 2010, 8 (06): : 23 - 23
  • [30] In vivo dosimetry in brachytherapy
    Tanderup, Kari
    Beddar, Sam
    Andersen, Claus E.
    Kertzscher, Gustavo
    Cygler, Joanna E.
    MEDICAL PHYSICS, 2013, 40 (07)