Negative effect of seroma on breast balloon brachytherapy dosimetry

被引:2
|
作者
Bhatt, Aashish D. [1 ]
Barry, Parul N. [2 ]
Sowards, Keith T. [2 ]
Dragun, Anthony E. [2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, 1 Emerson Pl,Apt 3-O, Boston, MA 02114 USA
[2] Univ Louisville, Dept Radiat Oncol, Louisville, KY 40292 USA
关键词
D O I
10.1016/j.prro.2013.03.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Balloon brachytherapy is commonly used to deliver Accelerated Partial Breast Irradiation (APBI). Seroma interference is a relatively common phenomenon during APBI. The negative effect of seroma accumulation on the planning target volume evaluation (PTV_Eval) coverage is not well understood. Methods and Materials: This is a dosimetric replanning study on 10 patients with evidence of seroma collection at time of initial computed tomographic simulation around the catheter. Total dose was 34 Gy given at 3.4 Gy twice a day over 5 treatment days. A total of 20 plans were generated, 10 plans without accounting for and 10 after subtracting the seroma. We then compared the changes seen in PTV_Eval between plans as a factor of the seroma volume. Results: Median age was 62 years (51-83). Histology was invasive in 7/10 cases and in situ in 3/10. Median balloon to skin distance was 8.5 mm (3-14). Median balloon volume was 39 cc (30-104). Median seroma volumewas 3.34 cc (1.13-13.71). For every 1 cc of accumulated seroma the percentage of PTV_Eval coverage by the 90% isodose line (V90) was found to decrease by 2.45% (P < .0001; confidence interval [CI], 1.87-3.03) and coverage by the 100% isodose line (V100) was decreased by 1.11% (P < .0001; CI, 0.81-1.41). Fifty percent (5/10) of previously acceptable plans with seroma not accounted for failed to meet the V90 >= 90% requirement after subtracting the seroma. Conclusions: Accumulation of seroma was associated with a considerable negative impact on PTV_Eval dosimetry with a greater impact on V90 compared with the V100. Clinicians must be careful in detecting and accounting for such accumulation in treatment plans to prevent underdosing of the at risk target breast tissue. (C) 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:E1 / E5
页数:5
相关论文
共 50 条
  • [1] Impact of interfraction seroma collection on breast brachytherapy dosimetry - a mathematical model
    Bhatt, Aashish
    Sowards, Keith
    Bhatt, Geetika
    Freeman, Andrew
    Dragun, Anthony
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2012, 4 (02) : 101 - 105
  • [2] Interface dosimetry for electronic brachytherapy intracavitary breast balloon applicators
    Segala, James J.
    Cardarelli, Gene A.
    Hiatt, Jessica R.
    Curran, Bruce H.
    Sternick, Edward S.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02): : 293 - 300
  • [3] Dosimetry of a balloon source for intravascular brachytherapy.
    Soares, C
    Trauthen, B
    Tam, L
    Seltzer, S
    Strathearn, G
    Buchbinder, M
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (7A): : 76S - 77S
  • [4] In vivo dosimetry of skin dose during HDR breast brachytherapy using balloon catheter
    Kim, S.
    Oh, S.
    Gales, A.
    Vallow, L. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S524 - S525
  • [5] Intraoperative placement of MammoSite for breast brachytherapy treatment and seroma incidence
    Ravi, Akkamma
    Lee, Susan
    Karsif, Karen
    Osian, Adrian
    Nori, Dattatreyudu
    BRACHYTHERAPY, 2010, 9 (01) : 76 - 80
  • [6] Dosimetry of beta nuclide filled balloon catheter in endovascular brachytherapy
    Chen, YM
    Geng, JH
    Tian, JH
    Yin, DY
    Chen, SZ
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2004, 14 (03) : 337 - 339
  • [7] Incidence and prognostic factors for seroma development after MammoSite breast brachytherapy
    Watkins, John M.
    Harper, Jennifer L.
    Dragun, Anthony E.
    Ashenafi, Michael S.
    Sinha, Debajyoti
    Li, Jun
    Cole, David J.
    Jenrette, Joseph M.
    BRACHYTHERAPY, 2008, 7 (04) : 305 - 309
  • [8] Identifying the impact of seroma visualization on permanent breast seed implant brachytherapy
    Morton, Daniel
    Batchelar, Deidre
    Hilts, Michelle
    Tetreault-Laflamme, Audrey
    Mou, Benjamin
    Lucas, Sarah
    Crook, Juanita
    MEDICAL PHYSICS, 2016, 43 (08) : 4934 - 4934
  • [9] Seroma Visualization and Implant Accuracy in Permanent Breast Seed Implant Brachytherapy
    Morton, Daniel
    Hilts, Michelle
    Batchelar, Deidre
    Tetreault-Laflamme, Audrey
    Mou, Benjamin
    Crook, Juanita
    PRACTICAL RADIATION ONCOLOGY, 2019, 9 (03) : E314 - E321
  • [10] Evaluation of the Effects of Balloon Deformation and Position of the Source on Dosimetry in High-dose Rate Mammosite Breast Brachytherapy
    Negusse, S.
    Ali, I.
    Algan, O.
    Thompson, S.
    Herman, T.
    Ahmad, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S695 - S695