DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR DETERMINATION OF SOME HEAVY METALS IN URANIUM

被引:0
|
作者
Saryati [1 ]
机构
[1] Natl Nucl Energy Agcy BATAN, Technol Ctr Nucl Ind Mat, Jakarta, Indonesia
关键词
heavy metal determination; differential pulse anodic stripping voltammetry; uranium;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The direct determination of some metals impurity in uranium by using differential pulse anodic stripping voltammetry (DPASV) method at a hanging mercury drop electrode and in a carbonate buffer media was developed. It was found that the carbonate buffer show the strongest affinity for uranium and gives the best separation between the DPASV peaks of heavy metals impurities. The carbonate concentration markedly affects the oxidation and reduction the major and the minor constituents of the uranium samples. In 0.1 M carbonate buffer solution pH 10, copper, bismuth, thalium, lead, cadmium, zinc, could be determined without the removal of the uranium matrix. Recovery and relative standard deviation (RSD) of this method was in the range of 174% - 85.2% for recovery and 36.8% - 1.2% for RSD. The larger error of analytical result was obtained for Zn at low concentration. In general, the analytic results error and RSD decreased with increasing metals concentration.
引用
收藏
页码:243 / 246
页数:4
相关论文
共 50 条
  • [41] DIRECT DETERMINATION OF ARSENIC IN URINE BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    FRANKE, JP
    DEZEEUW, RA
    PHARMACEUTISCH WEEKBLAD-SCIENTIFIC EDITION, 1981, 3 (04) : 1042 - 1047
  • [42] TRACE LEVEL DETERMINATION OF GALLIUM BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    DESHPANDE, SS
    JOSHI, AP
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1987, 26 (09): : 797 - 798
  • [43] SIMULTANEOUS DETERMINATION OF TRACE-METALS IN INDUSTRIAL AND DOMESTIC EFFLUENTS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    KINARD, JT
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1977, 12 (10): : 531 - 547
  • [44] Water analysis for heavy metals using differential pulse stripping voltammetry.
    Eggleston, MJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 216 - CHED
  • [45] The use of differential pulse anodic stripping voltammetry and diffusive gradient in thin films for heavy metals speciation in soil solution
    Dytrtova, Jana Jaklova
    Sestakova, Ivana
    Jakl, Michal
    Szakova, Jirina
    Miholova, Daniela
    Tlustos, Pavel
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2008, 6 (01): : 71 - 79
  • [46] Economic bismuth-film microsensor for anodic stripping analysis of trace heavy metals using differential pulse voltammetry
    Sophie Legeai
    Koïkoï Soropogui
    Martin Cretinon
    Olivier Vittori
    Arno Heeren De Oliveira
    Frédérique Barbier
    Marie-Florence Grenier-Loustalot
    Analytical and Bioanalytical Chemistry, 2005, 383 : 839 - 847
  • [47] Economic bismuth-film microsensor for anodic stripping analysis of trace heavy metals using differential pulse voltammetry
    Legeai, S
    Soropogui, K
    Cretinon, M
    Vittori, O
    De Oliveira, AH
    Barbier, F
    Grenier-Loustalot, MF
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (05) : 839 - 847
  • [48] Electrodialytic Matrices Isolation for Determination of Heavy Metals in Soil Extracts by Anodic Stripping Voltammetry
    Ohira, Shin-Ichi
    Okazaki, Chinatsu
    Toda, Kei
    BUNSEKI KAGAKU, 2018, 67 (12) : 761 - 766
  • [49] ANODIC STRIPPING PULSE VOLTAMMETRY
    CHRISTIA.GD
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1969, 23 (01): : 1 - &
  • [50] Determination of Tl(I) Ions in Homeopathic Drugs by Differential Pulse Anodic Stripping Voltammetry
    Zembrzuski, Wlodzimierz
    Karbowska, Bozena
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2017, 51 (04) : 620 - 625