DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR DETERMINATION OF SOME HEAVY METALS IN URANIUM

被引:0
|
作者
Saryati [1 ]
机构
[1] Natl Nucl Energy Agcy BATAN, Technol Ctr Nucl Ind Mat, Jakarta, Indonesia
关键词
heavy metal determination; differential pulse anodic stripping voltammetry; uranium;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The direct determination of some metals impurity in uranium by using differential pulse anodic stripping voltammetry (DPASV) method at a hanging mercury drop electrode and in a carbonate buffer media was developed. It was found that the carbonate buffer show the strongest affinity for uranium and gives the best separation between the DPASV peaks of heavy metals impurities. The carbonate concentration markedly affects the oxidation and reduction the major and the minor constituents of the uranium samples. In 0.1 M carbonate buffer solution pH 10, copper, bismuth, thalium, lead, cadmium, zinc, could be determined without the removal of the uranium matrix. Recovery and relative standard deviation (RSD) of this method was in the range of 174% - 85.2% for recovery and 36.8% - 1.2% for RSD. The larger error of analytical result was obtained for Zn at low concentration. In general, the analytic results error and RSD decreased with increasing metals concentration.
引用
收藏
页码:243 / 246
页数:4
相关论文
共 50 条
  • [31] DETERMINATION OF MERCURY IN FISH USING DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    GOLIMOWSKI, J
    GUSTAVSSON, I
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 317 (3-4): : 481 - 481
  • [32] Determination of zinc in high purity gallium by differential pulse anodic stripping voltammetry
    Sounderajan, S
    Singh, A
    Palrecha, MM
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2002, 41 (07): : 1433 - 1435
  • [33] DETERMINATION OF LEAD IN PAINT BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY
    LAI, PC
    FUNG, KW
    ANALYST, 1978, 103 (1233) : 1244 - 1248
  • [34] Determination of Pb and Zn in pottery using differential pulse anodic stripping voltammetry
    Ghumare, S
    Joshi, AP
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1998, 37 (10): : 942 - 944
  • [35] TRACE LEVEL DETERMINATION OF ZINC BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    DESHPANDE, SS
    JOSHI, AP
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1988, 27 (02): : 179 - 180
  • [36] Determination of cadmium in sewage sludge by differential pulse anodic stripping voltammetry.
    Pacer, RA
    Ellis, CK
    Peng, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U161 - U161
  • [37] DIFFERENTIAL PULSE POLAROGRAPHY AND DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY FOR DETERMINATION OF TRACE LEVELS OF THALLIUM
    HOEFLICH, LK
    GALE, RJ
    GOOD, ML
    ANALYTICAL CHEMISTRY, 1983, 55 (09) : 1591 - 1595
  • [38] DETERMINATION OF ARSENIC IN POLLUTED WATERS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    LEUNG, PC
    SUBRAMANIAN, KS
    MERANGER, JC
    TALANTA, 1982, 29 (06) : 515 - 518
  • [39] Determination of lead and cadmium in titanium dioxide by differential pulse anodic stripping voltammetry
    Panigati, M
    Piccone, M
    D'Alfonso, G
    Orioli, M
    Carini, M
    TALANTA, 2002, 58 (03) : 481 - 488
  • [40] DETERMINATION OF THALLIUM IN LEAD SALTS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    CISZEWSKI, A
    LUKASZEWSKI, Z
    TALANTA, 1983, 30 (11) : 873 - 875