DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR DETERMINATION OF SOME HEAVY METALS IN URANIUM

被引:0
|
作者
Saryati [1 ]
机构
[1] Natl Nucl Energy Agcy BATAN, Technol Ctr Nucl Ind Mat, Jakarta, Indonesia
关键词
heavy metal determination; differential pulse anodic stripping voltammetry; uranium;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The direct determination of some metals impurity in uranium by using differential pulse anodic stripping voltammetry (DPASV) method at a hanging mercury drop electrode and in a carbonate buffer media was developed. It was found that the carbonate buffer show the strongest affinity for uranium and gives the best separation between the DPASV peaks of heavy metals impurities. The carbonate concentration markedly affects the oxidation and reduction the major and the minor constituents of the uranium samples. In 0.1 M carbonate buffer solution pH 10, copper, bismuth, thalium, lead, cadmium, zinc, could be determined without the removal of the uranium matrix. Recovery and relative standard deviation (RSD) of this method was in the range of 174% - 85.2% for recovery and 36.8% - 1.2% for RSD. The larger error of analytical result was obtained for Zn at low concentration. In general, the analytic results error and RSD decreased with increasing metals concentration.
引用
收藏
页码:243 / 246
页数:4
相关论文
共 50 条
  • [1] DETERMINATION OF ARSENIC BY ANODIC STRIPPING VOLTAMMETRY AND DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY
    OLAUGHLI.JW
    FORSBERG, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1973, (AUG26): : 34 - 34
  • [2] Estimation of Heavy Metals in Multivitamin Tablets by Differential Pulse Anodic Stripping Voltammetry
    Raj, Kumar Rohit
    Sharma, Shashank
    Saxena, Sachin
    Srivastava, M. M.
    Satsangi, Soami P.
    E-JOURNAL OF CHEMISTRY, 2010, 7 : S169 - S174
  • [3] Determination of wear metals in lubricating oils by differential pulse anodic stripping voltammetry
    Sanz-Segundo, C
    De Cisneros, JLHH
    Hernández-Artiga, MP
    Naranjo-Rodríguez, I
    Bellido-Milla, D
    BULLETIN OF ELECTROCHEMISTRY, 2002, 18 (04): : 165 - 172
  • [4] Anodic stripping voltammetry - ASV for determination of heavy metals
    Baron-Jaimez, J.
    Joya, M. R.
    Barba-Ortega, J.
    2ND INTERNATIONAL MEETING FOR RESEARCHERS IN MATERIALS AND PLASMA TECHNOLOGY, 2013, 466
  • [5] DETERMINATION OF ARSENIC BY ANODIC-STRIPPING VOLTAMMETRY AND DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    FORSBERG, G
    OLAUGHLIN, JW
    MEGARGLE, RG
    KOIRTYOHANN, SR
    ANALYTICAL CHEMISTRY, 1975, 47 (09) : 1586 - 1592
  • [6] Determination of thallium by differential pulse anodic stripping voltammetry
    Karbowska, Bozena
    Zembrzuski, Wlodzimierz
    Wojtkowiak, Tomasz
    Lukaszewski, Zenon
    PRZEMYSL CHEMICZNY, 2014, 93 (06): : 978 - 982
  • [7] DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY OF TRACE HEAVY-METALS IN WATER
    MIWA, T
    MIZUIKE, A
    BUNSEKI KAGAKU, 1977, 26 (09) : 588 - 592
  • [8] DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR MERCURY DETERMINATION
    Verestiuc, Paul C.
    Tucaliuc, Oana-Maria
    Breaban, Iuliana G.
    Cretescu, Igor
    Nemtoi, Gheorghe
    ACTA CHEMICA IASI, 2015, 23 (01) : 13 - 24
  • [9] APPLICATION OF DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY TO THE DETERMINATION OF HEAVY-METALS IN ENVIRONMENTAL-SAMPLES
    OSTAPCZUK, P
    VALENTA, P
    RUTZEL, H
    NURNBERG, HW
    SCIENCE OF THE TOTAL ENVIRONMENT, 1987, 60 : 1 - 16
  • [10] Determination of metals in a multicomponent system by differential pulse and alternating current anodic stripping voltammetry
    Locatelli, C
    Vasca, E
    Bighi, C
    Fagioli, F
    Garai, T
    ELECTROANALYSIS, 1996, 8 (02) : 165 - 170