摘要
To investigate how to reach 4 K using a pulse tube and the best multiple staging configuration for the pulse tube, experiments were performed on several types of single-stage pulse tube refrigerators coupled with a Gifford-McMahon cryocooler. The minimum temperature obtained at the cold end of the pulse tube using this unit was 3.5 K, when the hot end of the pulse tube was located at room temperature. The hot end of the final stage regenerator was precooled at almost-equal-to 15-20 K. The optimum operating conditions involved a mean pressure of almost-equal-to 1.0-1.5 MPa and a frequency of almost-equal-to 1-2 Hz. Heat flow and loss analysis, as related to the phase shift effect, as well as the arrangement of the multi-stage pulse tube refrigerator for reaching 4 K, are briefly discussed.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 50 条
  • [21] An experimental investigation of a single-stage two-pulse-tube refrigerator
    Yuan, J
    Pfotenhauer, JM
    CRYOCOOLERS 9, 1997, : 295 - 300
  • [22] Experimental and simulation investigation on high power 4 K pulse tube cryocooler
    Dong, Wen-Qing
    Qiu, Li-Min
    Wang, Chao
    Gan, Zhi-Hua
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2011, 32 (10): : 1627 - 1630
  • [23] Modification test of staged pulse tube refrigerator for temperatures below 4 K
    Chen, GB
    Zheng, JY
    Qiu, LM
    Bai, X
    Gan, ZH
    Yan, PD
    Yu, JP
    Jin, T
    Huang, ZX
    CRYOGENICS, 1997, 37 (09) : 529 - 532
  • [24] Investigation on phase shifter of a 10 W/70 K inertance pulse tube refrigerator
    Liu, Shaoshuai
    Chen, Xi
    Zhang, Ankuo
    Wu, Yinong
    Zhang, Hua
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 74 : 450 - 457
  • [25] 92 K thermoacoustically driven pulse tube refrigerator
    Tang, K
    Chen, GB
    Jin, T
    Kong, B
    Bao, R
    Qiu, LM
    Gan, ZH
    CHINESE SCIENCE BULLETIN, 2004, 49 (14): : 1541 - 1542
  • [26] Experimental investigation of the connecting tube effect on a step displacer type two stage pulse tube refrigerator
    Lin, Yuzhe
    Guo, Zhaorui
    Guo, Zhimin
    Zhu, Shaowei
    APPLIED THERMAL ENGINEERING, 2020, 173 (173)
  • [27] Experimental and numerical investigation on performance of a double inlet type cryogenic pulse tube refrigerator
    Biswas, Animesh
    Ghosh, Subrata K.
    HEAT AND MASS TRANSFER, 2016, 52 (09) : 1899 - 1908
  • [28] 92 K thermoacoustically driven pulse tube refrigerator
    TANG Ke
    ChineseScienceBulletin, 2004, (14) : 1541 - 1542
  • [29] 80 K miniature pulse tube refrigerator performance
    David, M
    Marechal, JC
    CRYOCOOLERS 9, 1997, : 223 - 228
  • [30] Experimental Investigation of a Single-Stage Four-Valve Pulse Tube Refrigerator
    王坤
    鲁雪生
    顾安忠
    Journal of Shanghai Jiaotong University, 2007, (01) : 96 - 99