EXPERIMENTAL INVESTIGATION OF 4-K PULSE TUBE REFRIGERATOR

被引:1
|
作者
GAO, JL
MATSUBARA, Y
机构
[1] Atomic Energy Research Institute, Nihon University, Funabashi, Chiba, 274
关键词
PULSE TUBE REFRIGERATORS; LIQUID HELIUM TEMPERATURE; CRYOCOOLERS;
D O I
10.1016/0011-2275(94)90048-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
To investigate how to reach 4 K using a pulse tube and the best multiple staging configuration for the pulse tube, experiments were performed on several types of single-stage pulse tube refrigerators coupled with a Gifford-McMahon cryocooler. The minimum temperature obtained at the cold end of the pulse tube using this unit was 3.5 K, when the hot end of the pulse tube was located at room temperature. The hot end of the final stage regenerator was precooled at almost-equal-to 15-20 K. The optimum operating conditions involved a mean pressure of almost-equal-to 1.0-1.5 MPa and a frequency of almost-equal-to 1-2 Hz. Heat flow and loss analysis, as related to the phase shift effect, as well as the arrangement of the multi-stage pulse tube refrigerator for reaching 4 K, are briefly discussed.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 50 条
  • [11] INSTALLATION OF 4-K REFRIGERATOR IN DILUTION REFRIGERATOR WITH NUCLEAR DEMAGNETIZATION APPARATUS
    MATSUMOTO, K
    OKUDA, Y
    CRYOGENICS, 1993, 33 (11) : 1018 - 1022
  • [12] Dynamic experimental investigation of a multi-bypass pulse tube refrigerator
    Ju, YL
    Wang, C
    Zhou, Y
    CRYOGENICS, 1997, 37 (07) : 357 - 361
  • [13] Experimental investigation of a pulse tube refrigerator driven by a thermoacoustic prime mover
    Qiu, LM
    Chen, GB
    Jiang, N
    Jiang, YL
    Yu, JP
    CRYOCOOLERS 11, 2001, : 301 - 307
  • [14] High-frequency pulse-tube refrigerator for 4 K
    Tanaeva, I. A.
    Bos, C. G. Klaasse
    de Waele, A. T. A. M.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 821 - +
  • [15] 4K pulse tube refrigerator and excess cooling power
    Zhu, SW
    Ichikawa, M
    Nogawa, M
    Inoue, T
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 633 - 640
  • [16] A pulse tube refrigerator below 2 K
    Xu, MY
    De Waele, ATAM
    Ju, YL
    CRYOGENICS, 1999, 39 (10) : 865 - 869
  • [17] Investigation of step piston pulse tube refrigerator
    Xu, Sheng
    Yang, Bin
    Zhu, Shaowei
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [18] Experimental investigation on regenerator materials of Stirling-type pulse-tube refrigerator working at 20 K
    Zhou, Qiang
    Chen, Liubiao
    Pan, Changzhao
    Zhou, Yuan
    Wang, Junjie
    PROCEEDINGS OF THE 25TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2014, 2015, 67 : 530 - 535
  • [19] Experimental Investigation of Superconducting Linear Compressor (SCLC) for Pulse Tube Refrigerator (PTR)
    Park, Jiho
    Park, Inmyong
    Cha, Jeongmin
    Jeong, Sangkwon
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [20] Experimental investigation of pulse tube refrigerator with rod type displacer as phase shifter
    Wang, Mingjun
    Xu, Haojie
    Lin, Yuzhe
    Zhang, Zhao
    Zhu, Shaowei
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 93 : 47 - 51