Problems of measurement with thermal imagers in determination of energy efficiency of buildings

被引:0
|
作者
Pusnik, Igor [1 ]
机构
[1] Univ Ljubljani, Fak Elektrotehn, Lab Metrol Kakovost, Trzaska 25, Ljubljana 1000, Slovenia
来源
ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW | 2008年 / 75卷 / 04期
关键词
thermal imager; energy efficiency of buildings;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper describes problems in the use of thermal imagers for determination of energy efficiency of buildings. Thermal imagers are commonly used in technical diagnostics and measurement of energy efficiency of buildings. A thermal imager captures an infrared (IR) image with an array of detectors (microbolometers). Analysis of an IR image is made with an associated software, in which parameters such as emissivity, distance, temperature and humidity are defined. According to recent analyses, only some 10 % of thermal imagers are accurate within the set manufacturers specifications. Therefore, it is important to use calibrated thermal imagers, when absolute temperature values are important. There are less problems when measuring temperature differences, but not all thermal imagers are capable of measuring them accurately. In their practical use, the following effects have to be taken into account: operating conditions (temperature, relative humidity), thermal capacitance, night sky, influence of athmosphere and distance, angle of measurement, reflected radiation from the surrounding, wind, etc. In our practical examples we show measurement of house and snow with two different thermal imagers (low cost and expensive) under the same measurement conditions. Figures 1A, 1B and 3 (A, B, C, D) were made with a low-cost thermal imager (resolution of the IR detector 160x120), while Figures 2A, 2B and 4 (A, B, C) were made with an expensive thermal imager (resolution of the IR detector 320x240). Both thermal imagers were calibrated in our laboratory under laboratory conditions and showed good agreement with the manufacturer specifications regarding accuracy (+/- 2 degrees C or 2 % of reading for the low-cost thermal imager and +/- 1 degrees C or 1 % of reading for the expensive thermal imager. Our analysis of the measured results shows good performance of the expensive thermal imager not only in measurement of temperature differences (Table 1B) but also in measurement of the absolute temperature (Table 1A). Results obtained with the low-cost thermal imager are completely different. Here all the measurement values are questionnable and the majority of them are physically quite impossible. It is obvious that the low-cost thermal imager is sensitive to changing operating conditions, which was especially evident when measuring snow. Before choosing a thermal imager its purpose and required accuracy should be defined. Measurement of the absolute temperature with accuracy better than +/- 1 degrees C is hard to achieve with a thermal imager, even if the manufacturer specifications claim so. Accuracy of a thermal imager is determined by calibration in an accredited laboratory issuing a calibration certificate. As a rule, thermal imager manufacturers do not provide them, at least not for free. Moreover, a calibrated and accurate thermal imager does not necessarily provide accurate measurements. To assure accurate measurements with an accurate thermal imager, a competent and experienced operator is required, too.
引用
收藏
页码:171 / 176
页数:6
相关论文
共 50 条
  • [31] EVALUATION OF ENERGY EFFICIENCY OF BUILDINGS
    Cretu, Raluca Florentina
    Cretu, Romeo Catalin
    QUALITY-ACCESS TO SUCCESS, 2018, 19 : 188 - 194
  • [32] Energy efficiency in complex buildings
    Hyseni, Driton
    Tasheyski, Done J.
    Filkoski, Risto, V
    Shesho, Igor K.
    SUSTAINABILITY IN THE BUILT ENVIRONMENT FOR CLIMATE CHANGE MITIGATION (SBE19), 2020, 410
  • [33] Designing buildings for energy efficiency
    Pupilli, S., 1600, (43):
  • [34] Energy efficiency design of buildings
    Jones, Phil
    Wang, Yan
    Li, Qian
    2006 XI'AN INTERNATIONAL CONFERENCE OF ARCHITECTURE AND TECHNOLOGY, PROCEEDINGS: ARCHITECTURE IN HARMONY, 2006, : 649 - 656
  • [35] Historic Buildings and Energy Efficiency
    Pracchi, Valeria
    HISTORIC ENVIRONMENT-POLICY & PRACTICE, 2014, 5 (02): : 210 - 225
  • [36] How Thermal Comfort affects the Energy-Efficiency Gap in Residential Buildings
    Hinker, Jonas
    Pohl, Oliver
    Myrzik, Johanna M. A.
    2015 50TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2015,
  • [37] Optimization of energy efficiency and thermal comfort measures for residential buildings in Salamanca, Mexico
    Griego, Danielle
    Krarti, Moncef
    Hernandez-Guerrero, Abel
    ENERGY AND BUILDINGS, 2012, 54 : 540 - 549
  • [38] Harnessing machine learning for enhanced thermal insulation and energy efficiency in buildings worldwide
    Fellah, Mohammed
    Ouhaibi, Salma
    Belouaggadia, Naoual
    Mansouri, Khalifa
    RESULTS IN ENGINEERING, 2025, 25
  • [39] Thermal Performance and Energy Efficiency of Lightweight Steel Buildings: a Case-Study
    Buzatu, Raluca
    Muntean, Daniel
    Ciutina, Adrian
    Ungureanu, Viorel
    5TH WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM (WMCAUS), 2020, 960
  • [40] CITIZENS' ATTITUDES ON ENERGY EFFICIENCY Thermal comfort and air quality in apartment buildings
    Milovanovic, Bojan
    Bagaric, Marina
    GRADEVINAR, 2022, 74 (12): : 1110 - 1114